Secondhand Hikoneb Oxybreath Mini 5 5L/min Oxygen Concentrator

, , , ,

Price: USD$ 160,00 Approx: 7.200,00 TL

Sold Out

Don't Want To Buy At This Price?

Sorry. This product has been sold. You cannot bid. Please check out other products.

Ask a Question

    Fill in the form below to send us your message. Click the button and wait. We will contact you as soon as possible.


    * We kindly ask you to write your Whatsapp number with the country code so that we can contact you quickly.

    Click once and wait.

    Payment

    No additional fees, full assurance. We provide complete financial and operational security in secondhand medical device trading. For this, we offer the "Secure Payment" service. This free service protects the rights of both parties by securing the buyer's money and the seller's product. The Secure Payment system is a standard assurance mechanism offered by Medbidding. For additional information, review the "services" page.

    There is no cash on delivery order system on the Medbidding platform. For payments to be made by credit card, the product to be purchased must comply with this payment method. You can contact us to get information about this. We would be happy to assist you.

    For payments made outside of Turkiye, you can choose bank transfer, credit card, Western Union or cryptocurrency options. Installment options are not currently available for credit cards other than Turkish banks.

    Shipping

    Standard Shipping Conditions

    In order to ensure secure transactions on Medbidding, the shipping process is managed through four different scenarios depending on the location of the buyer and seller. Free shipping is available for some categories. The terms below apply to all categories unless otherwise stated.

    Buyer and Seller in Turkiye

    • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
    • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

    Buyer Outside Turkiye, Seller in Turkiye

    • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
    • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

    Buyer in Turkiye, Seller Outside Turkiye

    • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
    • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

    Buyer and Seller Outside Turkiye

    If there is a local operation center in the seller's country:

    • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
    • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

    If there is no operation center in the seller's country:

    • Technical Inspection: Inspections are performed by our engineers via remote video call.
    • Seller → Buyer: The seller packages the product and sends it directly to the buyer's address. The seller is responsible for this shipping cost.

    Objective AI Report

    Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.

    Report date: 23.01.2026

    Hikoneb OxyBreath Mini Oxygen Concentrator Analysis Report

    Device Identification, Brand and Model Information

    As a result of the detailed visual inspection, the analyzed device has been definitively identified as a medical oxygen concentrator. The brand and model indications on the front face of the device are clear and legible:

    • Brand: Hikoneb
    • Model: OxyBreath Mini
    • Device Type: Oxygen Concentrator

    On the device labels, the brand logo is clearly stated as “hikoneb” and the model name as “OxyBreath Mini”. In light of this information, the product’s identification has been definitively made.

    Technical Specifications and Label Analysis

    The following technical data can be clearly read from the information label positioned vertically on the front right side of the device:

    • Oxygen Capacity: Has an oxygen flow rate capacity of 5 Liters/Minute.
    • Oxygen Purity: Stated to provide oxygen at %93 purity (with a ±3 deviation).
    • Power Consumption: The energy consumption value is indicated with the phrase “265 Watt/Hour” and emphasized as “Most Economical”.
    • Weight: The phrase “Lightest” is included with a net weight of “15.25 Kilograms”.
    • Raw Material Information: “European Manufactured Zeolite” is declared on the label as being used.

    Areas of Use

    Hikoneb OxyBreath Mini is a medical device used to separate oxygen from ambient air and provide high-concentration oxygen support to patients. It is designed for long-term oxygen therapy at home or in clinical settings, primarily for the treatment of patients suffering from COPD (Chronic Obstructive Pulmonary Disease), asthma, and respiratory failure. The device in the image is a main unit.

    Available Accessories and Missing Parts Status

    The product in the image consists of 1 unit of the main device. The conditions identified as a result of the inspection are as follows:

    • Humidifier Bottle: The slot where the humidifier bottle should be attached in the middle section of the device is empty. The water container (bottle) required for the device to be ready for use is not present in the image, which is a deficiency.
    • Cable and Cannula: Accessories such as the power cable, nasal cannula, or mask belonging to the device are not visible in the image.
    • Metal Outlet Tip: A threaded oxygen outlet point made of yellow brass material is present above the humidifier slot.

    Control Panel and Screen Analysis

    The control panel is located on the left front face of the device:

    • Screen: An LCD information screen is present on the device. Since the device is turned off, no operating hours or warning messages are displayed on the screen.
    • Warning Lights (Oxygen Monitor): LED indicators for “High Purity”, “Purity Drop”, and “Service Required” are present.
    • Power Switch: A green “I/0” (On/Off) switch is located at the top left corner of the device.
    • Flowmeter: On the right side, there is a manually adjustable glass tube indicator (flowmeter) showing a range of 0 to 5 L/min, with a black adjustment knob above it. The glass tube appears intact.

    General Condition, Cosmetics, and Physical Deformation

    The general cosmetic condition of the product is evaluated as “used”:

    • Case Cleanliness: There are localized dust accumulation and light surface dirt on the white plastic outer casing due to use. However, no deep cracks or breaks have been detected.
    • Structural Integrity: The device’s casing is intact; no disintegration or fragmentation is visible. Some of the wheels at the bottom are within the visual angle and appear to be present.
    • Warning Labels: The warnings “Use No Oil”, “No Smoking”, “No Open Flame” on the panel are legible. Warnings against opening the casing due to the risk of electric shock are present on the lower left side.

    Potential Malfunction Risk and Evaluation

    During the visual inspection, no major damage (such as cracks, broken cables, etc.) that would create an operational impediment was observed on the device’s outer casing or mechanical buttons (flowmeter knob, power switch). The absence of the humidifier bottle indicates that the product is not immediately ready for use; this part must be obtained separately. Since the device’s LCD screen is off, the total operating hours (a critical data point for compressor lifespan) or whether the “Service Required” light is on cannot be determined. Its physical condition is medium-to-good, presenting the appearance of a standard second-hand medical device.