Objective AI Report
Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.
Report date: 28.11.2025
MIC CP501-T Oxygen Concentrator Analysis Report
Device Identification
The device shown in the visuals is an electric Oxygen Concentrator used for medical purposes, which separates ambient air to produce high-concentration oxygen. Thanks to its wheeled structure, the device is designed as a portable (home-use) model and features characteristic components such as a water reservoir (humidifier), a flow meter, and a digital display on its front panel.
Brand and Model Information
As a result of the examination of the technical label on the back of the device, the product’s identification details have been definitively determined:
- Brand: MIC
- Model: CP501-T
- Manufacturer: FOSHAN MIC MEDICAL TECHNOLOGY CO., LTD.
It is understood from the Turkish phrases on the label that the device’s distribution in Turkey is carried out by “ELMASLAR İMALAT TIBBİ CİHAZLAR A.Ş.”. This model falls into the category of standard 5-liter home-use oxygen concentrators.
Label and Technical Data
The technical details read from the information label on the rear panel (Image 4) are as follows:
- Device Type: OXYGEN CONCENTRATOR
- Maximum Flow Rate: 5LPM (5 Liters Per Minute)
- Power Ratings: 230V~ 50Hz, 1.6 Amps
- Serial Number / Barcode: C05AO2119073
- Production Date: 2021.11.03 (November 3, 2021)
- IP Protection Class: IP21
- Certification: CE 0197 mark is present.
General Condition and Cosmetic Inspection
The device is generally in a used condition. No breaks, cracks, or significant dents were observed on the outer plastic casing. However, the following details are noteworthy:
- Casing Cleanliness: Light dust accumulation is present on the general surfaces of the device. Traces of use are visible, particularly on the upper handle and plastic joints.
- Filter Condition: The black air intake sponge/filter (Image 4) located at the lower rear part of the device has a significant accumulation of dirt and dust. The filter pores appear greyish.
- Front Panel: The labels on the control panel and buttons are clean and legible. No significant discoloration is apparent.
Mechanical and Electronic Components
The analysis of technical components based on visual inspection is as follows:
- Wheels: Black wheels providing mobility are present underneath the device and are in place.
- Flow Meter: The tube with a manual adjustment valve located on the front right side appears intact. The scale is between 0 and 5 liters.
- Display: A digital LCD screen is present on the front of the device. Since the device is off, data such as operating hours on the screen cannot be read, but no physical damage is visible on the screen surface.
- Buttons: The On/Off switch (I/O), 4 AMP circuit breaker button, and other control buttons are physically in place.
Accessories and Missing Parts
The number of products in the visuals is 1 main device. The accessories visible on the device are as follows:
- Humidifier Water Bottle: A transparent water reservoir secured to the front panel with a strap is present.
- Interconnecting Hose: A short silicone hose connecting the device’s oxygen outlet to the water bottle is attached.
- Power Cable: The black power cable is connected to the device.
Note: The nasal cannula or mask used for oxygen delivery to the patient is not present in the visuals. This part may need to be supplied separately.
Areas of Use
The MIC CP501-T is used for home care treatment, especially in respiratory conditions such as COPD (Chronic Obstructive Pulmonary Disease), asthma, or when blood oxygen saturation drops. It has the capacity to provide a continuous oxygen flow of up to 5 liters per minute. It is suitable for use only when medically necessary and upon expert recommendation.
Originality Assessment
Upon examining the labels, material quality, molding workmanship, and logos on the device, it is understood that the product is an original MIC branded production. It appears to be a standard medical device of Chinese origin, imported through legal channels (CE certified).
Potential Malfunction Risk
There is no visible evidence (such as broken parts or severed cables) that the device is electronically or mechanically faulty. However, the heavy dust accumulation in the rear air intake filter is a critical concern. If this filter is not cleaned, the device’s air intake may become difficult, which could lead to compressor overheating or a decrease in oxygen production performance. Provided the filter is cleaned or replaced, the device’s condition will improve to a good level.










