Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.
Report date: 25.05.2026
Report code: 1779718634
Respirox JLO-590i Oxygen Concentrator Analysis Report
Device Identification
The images show a medical device inside its original cardboard packaging. The information and illustrations on the packaging definitively indicate that this device is an oxygen concentrator.
Brand and Model
The Respirox brand and logo are clearly legible in capital letters on the front of the packaging. On the technical label located on the side of the packaging, the model information is specified as JLO-590i. In light of this information, the full name of the device is Respirox JLO-590i Oxygen Concentrator.
General Condition and Physical Deformation
The device remains sealed within its original cardboard box. On the outer surface of the box, slight crushing and wear on the corners due to transport or storage are visible. The top of the box is sealed with packing tape. There is a black fabric bag or cover on top of the box. Since the device itself is inside the box, no direct visual analysis could be performed regarding its physical condition, casing, screen, or mechanical components. The fact that the packaging is sealed gives the impression that the device may be unused or lightly used, although this is not certain.
Accessories
A black carrying bag with a handle is visible on top of the box. Other accessories of the device (cannula, humidifier bottle, filters, etc.) could not be visually identified as they may be inside the box. There are no visible socket inputs or external connection points on the box.
Label Information
The white label on the side of the box contains the following technical information and codes:
- Device Type: OXYGEN CONCENTRATOR
- Model: JLO-590i
- Serial Number (SN): HA2509652
- Power Supply: ~220V ± 22V, 50Hz±1Hz
- Input Power: 500VA
- Oxygen Purity Level: 93% ± 3% at a flow rate between 0-5L/min
- Weight: 24 Kg
- Outlet Pressure: 40kPa – 70kPa
- Dimensions: H56xW28.5xD47cm
- Manufacturing Date: 07/2025
- Barcode Number: 8 680845 006515
- Certification: CE 0413
- Manufacturer: Shenzhen Homed Medical Devices Co., Ltd.
- European Representative (EC REP): Shanghai International Holding Corp. GmbH (Europe)
- Importer: ECE TIBBİ CİHAZLAR VE MEDİKAL SAN. TİC. A.Ş.
- Origin: Made in P.R.C.
The label also contains technical symbols and warnings indicating the operating temperature (10°C – 35°C), relative humidity (20% – 60%), and atmospheric pressure (86kPa – 106kPa) ranges.
Usage Areas
This device is used to provide high-concentration oxygen to patients by filtering nitrogen from the ambient air. It is suitable for patients requiring oxygen therapy in home care, hospitals, or clinics. According to the information on the label, it can provide a flow rate between 0 and 5 liters per minute.
Dimensions and Compatibility
The dimensions of the device are stated on the label as H56xW28.5xD47cm. Its weight is 24 kg. These measurements indicate that the device is a portable model suitable for home use. While there is no specific information on the label regarding patient compatibility (infant/child/adult), a flow rate of 0-5L/min is generally suitable for adults and some pediatric patients.
Manufacturing Year and Documents
The manufacturing date is clearly stated on the technical label as 07/2025. No documents such as invoices or warranty certificates are visible in the images.
Potential Failure Risk
Since the device is packaged and sealed, no mechanical or electronic failure could be detected through the images. Apart from slight wear on the outside of the box, no serious damage, rust, or cable crushing that would negatively affect the condition of the device has been observed. As the integrity of the packaging is maintained, it can be said that the condition of the product is good.