Objective AI Report
Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.
Report date: 11.03.2026
Report code: 1773237934
RespiroX SZ-5BW Oxygen Concentrator Analysis Report
Device Identification and Areas of Use
The product in the images is an oxygen concentrator manufactured for patients requiring respiratory support. The device is used to produce oxygen from ambient air and deliver it to the patient. Thanks to the Nebulizing interface output located on the front panel, it also has the feature of being used as a nebulizer. It is suitable for use by patients requiring oxygen flow between 0 and 5 liters/minute in home care or clinical settings.
Brand and Model Information
The brand and model have been definitively identified based on the information on the manufacturer’s label located on the front panel and the rear of the device.
- Brand: RespiroX
- Model: SZ-5BW
General Condition and Physical State
The device is in used condition, but its general physical state is good. No breaks, cracks, dents, or discoloration have been observed on the gray and white plastic outer casing. Slight dust and fingerprint smudges are present on the black glossy panel on the front. The recessed carrying handles on the side panels are intact. The black rectangular filter cover on the rear is secured with screws and is completely in place.
Mechanical and Electronic Components
The LCD screen on the front panel of the device is physically intact; as the device was off when the image was taken, no data or warnings are displayed on the screen. There is no wear or deformation on the Run/Stop, Timing +, and Timing – membrane buttons located below the screen. The analog flowmeter (rotameter) on the front panel, capable of measuring between 1 and 5 L/min, is in good condition, and its float is at the lowest level. The on/off (I/O) switch located on the rear panel is physically undamaged. No visible crushing, peeling, or breakage has been detected on the black power cable emerging from the bottom rear of the device.
Accessories and Quantity Information
In the images, 1 main device and 1 accessory attached to the device have been identified.
- Humidifier Bottle: It is connected to the oxygen outlet on the front of the device via a transparent tube. There is some liquid inside the transparent plastic bottle. No physical damage is visible on the bottle or its connection fittings.
Label and Technical Specifications
The following technical data has been obtained from the manufacturer’s label located on the rear panel of the device.
- Serial Number (SN): KB210009034
- Manufacturing Date: 10/2021
- Power Supply: ~220V ± 22V, 50Hz ± 1Hz
- Input Power: 500VA
- Oxygen Flow Rate: 0-5 L/min
- Weight: 24 Kgs
- Dimensions: H56 x W31 x D43 cm
- Certification: CE0123
Authenticity Assessment
The print quality of the brand logos on the device, the detailed manufacturer’s label on the rear panel, the barcoding system, warning labels, and the CE certification mark indicate that the product is an original production. The workmanship at the casing joints complies with standards.
Existing Faults and Potential Risks
No broken parts, severed cables, missing hardware, or error messages on the screen that would prevent the device from operating have been detected in the images. There are no signs of rust or significant wear on the exterior surface of the device. Based on visual evidence, it is assessed that the device’s condition is good and it does not pose a potential risk of malfunction due to external components.