Approved

Ready For Sale

Whatsapp »
SKU: MB1ONXP6PZ2

Secondhand Yuwell 8F-5A 5L/min Oxygen Concentrator

, , , ,

Price: USD$ 250,00 Approx: 11.250,00 TL

Ready For Sale

Don't Want To Buy At This Price?

    Bid


    * We kindly ask you to write your Whatsapp number with the country code so that we can contact you quickly.

    Click once and wait.

    Ask a Question

      Fill in the form below to send us your message. Click the button and wait. We will contact you as soon as possible.


      * We kindly ask you to write your Whatsapp number with the country code so that we can contact you quickly.

      Click once and wait.

      Payment

      No additional fees, full assurance. We provide complete financial and operational security in secondhand medical device trading. For this, we offer the "Secure Payment" service. This free service protects the rights of both parties by securing the buyer's money and the seller's product. The Secure Payment system is a standard assurance mechanism offered by Medbidding. For additional information, review the "services" page.

      There is no cash on delivery order system on the Medbidding platform. For payments to be made by credit card, the product to be purchased must comply with this payment method. You can contact us to get information about this. We would be happy to assist you.

      For payments made outside of Turkiye, you can choose bank transfer, credit card, Western Union or cryptocurrency options. Installment options are not currently available for credit cards other than Turkish banks.

      Shipping

      Standard Shipping Conditions

      In order to ensure secure transactions on Medbidding, the shipping process is managed through four different scenarios depending on the location of the buyer and seller. Free shipping is available for some categories. The terms below apply to all categories unless otherwise stated.

      Buyer and Seller in Turkiye

      • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
      • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

      Buyer Outside Turkiye, Seller in Turkiye

      • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
      • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

      Buyer in Turkiye, Seller Outside Turkiye

      • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
      • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

      Buyer and Seller Outside Turkiye

      If there is a local operation center in the seller's country:

      • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
      • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

      If there is no operation center in the seller's country:

      • Technical Inspection: Inspections are performed by our engineers via remote video call.
      • Seller → Buyer: The seller packages the product and sends it directly to the buyer's address. The seller is responsible for this shipping cost.

      Objective AI Report

      Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.

      Report date: 27.02.2026

      Yuwell 8F-5A Oxygen Concentrator Analysis Report

      Device Identification

      The displayed device is a mobile-type oxygen concentrator that operates on electrical energy, separating oxygen from ambient air and delivering high-concentration oxygen to the patient.

      Brand and Model

      The brand logo Yuwell is clearly visible at the bottom of the device’s front surface, and the model code 8F-5A is clearly readable below the upper control panel.

      Originality

      Upon examining the brand logo print on the product, model code fonts, control panel layout, screen structure, and plastic molding craftsmanship, the product is assessed to be an original Yuwell production.

      Areas of Use

      This device is used for patients suffering from COPD, pulmonary fibrosis, heart failure, or respiratory failure to receive long-term oxygen therapy at home or in a clinical setting. It delivers oxygen flow to the patient at a specific liter per minute (L/min) via a nasal cannula or mask.

      Quantity Information

      There is 1 (one) oxygen concentrator device in the images.

      General Condition

      The device is in used condition. While the body integrity is preserved, usage marks are present upon detailed inspection. The device’s power is active, and its screen is operational.

      Physical Deformation

      No deep cracks or fractures have been detected on the white plastic outer casing. However, significant dust accumulation and dirt residues are present at the edge joints and between the buttons of the black control panel. Superficial stains are observed on the left central part of the front panel.

      Mechanical Components

      The four black transport wheels located at the bottom of the device are in place. The integrated carrying handle on the top appears sturdy. The flow adjustment knob (flowmeter knob) on the front surface is present.

      Electronic Components

      The image shows the device in the ON position. The control buttons (+, -, Power) on the upper panel are physically present. The upper green (I/O) light among the status LEDs to the right of the screen is illuminated, indicating that the device is powered and active.

      Accessories

      A transparent silicone tube is attached to the device’s OXYGEN OUTLET port. This tube is likely connected to the humidifier water bottle at the rear of the device (partially visible in the image). The original box, user manual, or spare filters are not present in the image.

      Battery Status

      This model (Yuwell 8F-5A) is a standard model that operates with mains electricity. No built-in battery feature has been detected in the image, and this is understood from the cable clutter in the background where the device’s power cord is plugged in.

      Label Information

      The following technical information is located on the front surface of the device:

      • Brand: yuwell
      • Model: 8F-5A
      • Function Indicator: TIMING and COUNTS indications
      • Flow Indicator: Graduated scale from 1 – 5 L/min (Flowrate)
      • Port Information: OXYGEN OUTLET

      Screen Analysis

      The device’s LCD screen is active, and data can be read:

      • TIMING: The “- – – – H” indication shows that no active timer is currently set.
      • COUNTS: The “04249 H” indication shows the device’s total cumulative operating hours.
      • LED Indicator: The green LED next to “I/O” is active; the “Triangle Exclamation” (fault/warning) LED is passive.

      Size and Compatibility

      The device is of standard home-use dimensions. The flowmeter on the front panel indicates a range of 0 to 5 Liters/Minute, which suggests that the device is suitable for adult use with a maximum capacity of 5 liters.

      Usage Duration

      According to the screen data, the device has operated for a total of 4249 hours (04249 H). In terms of compressor lifespan for oxygen concentrators, this data indicates that the device has reached a medium level of service life.

      Current Faults

      Visual analysis revealed that the screen is working properly, the power light is on, and the fault (alarm) light is not illuminated. No mechanical breaks or missing parts are observed.

      Potential Fault Risk

      Dust and dirt accumulation on the control panel indicate that the device might have been used in a dusty environment. This situation suggests the possibility that the device’s internal air intake filters are clogged or dirty. Filter maintenance should be checked; otherwise, compressor performance may be affected.