Ready For Sale
Secondhand Dr. J. Hansler Ozonosan Photonic Ozone Generator
Price: USD$ 14.000,00Approx: 588.000,00 TL
Ready For Sale
Ask a Question
Objective AI Report
Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.
Report date: 07.09.2025
Dr. J. Hänsler Ozonosan Photonic Ozone Therapy Device Analysis Report
General Assessment
The device shown in the visuals is a Dr. J. Hänsler brand, Ozonosan Photonic model ozone therapy device. Although the device’s general condition indicates it is used, it is observed to be in good physical condition. There are no significant deformations, breaks, or cracks on it. The label information is legible, and it is understood that the device was manufactured in 2008. No accessories are present in the visuals.
Brand and Model Information
The brand and model information are clearly legible on the manufacturer’s label located on the rear surface of the device. According to this information, the device’s brand has been identified as Dr. J. Hänsler and its model as Ozonosan Photonic. The originality of the device is evident from the quality of its labels, the CE mark, and general craftsmanship details.
Physical Condition Analysis
The physical condition of the device is generally good. Detailed inspection notes are listed below:
- Casing: No breaks, cracks, or significant dents were observed on the white casing of the device. There may be minimal, insignificant usage marks on the surface, but it generally has a clean appearance.
- Control Panel: The adjustment knobs, buttons, and digital display on the front panel are physically sound. There is no wear or fading on the buttons.
- Discoloration: A slight yellowing is present on the device’s rear label and casing; this is considered a normal and acceptable cosmetic condition given the device’s manufacturing year.
- Mechanical Components: The parts named “Katalysator” (Catalyst) and “Überlaufbehälter” (Overflow Reservoir) on the rear of the device, and the output section on the front, appear physically sound.
Technical Label Information
The label on the back of the device contains important technical details and the serial number. This information is listed below:
- Brand: DR. J. HÄNSLER GMBH
- Model (Type): OZONOSAN photonik
- Serial Number (SN): 1014 20066908
- Year of Manufacture: 2008
- Power Requirement: 230 VAC, 1.2A, 50 – 60 Hz
- Classification: Protective class I, Typ B
- Certification: CE 0535
Additionally, there is another label on the rear panel stating “K-1-0492”. A multilingual warning label advising that the device should be unplugged before opening is also present.
Screen, Accessories, and Connection Ports
Screen Status: The digital screen located at the top of the control panel is off in the visuals. Therefore, it is not possible to comment on whether the screen is operational or displaying any error messages. However, there are no breaks or cracks on the screen’s glass.
Accessories: Other than the device itself, no accessories such as a power cable, user manual, or application tools are present in the visuals. The device is reported as being without accessories.
Connection Ports: A metal output socket is located at the front bottom of the device. On the rear panel, there are two more connection points labeled “Eingangsdruck” (Input Pressure) and “Auslass” (Output). All connection points are visually in good condition.
Potential Risk Assessment
No visible serious damage, rust, crushed cables, or broken parts that could indicate a potential malfunction have been detected on the device. Despite its year of manufacture, the device appears to have been well-preserved and is in good physical condition. Therefore, based on the visuals, no significant issue posing an immediate malfunction risk has been observed.