Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.
Report date: 20.05.2026
Report code: 1779275169
Löwenstein Medical Prisma30ST PAP Device Analysis Report
Device Identification
The images show one positive airway pressure (PAP) device main unit, one integrated humidifier unit, and various accessories.
Brand and Model
The Löwenstein Medical brand and Prisma30ST model information are clearly legible on the main unit of the device. The prismaAQUA inscription is present on the humidifier unit.
Authenticity
The quality of the logos on the device, the placement of the labels, the casing craftsmanship, and the screen structure present the appearance of an original product.
Usage Areas
This device is a BiLevel (two-level) PAP device used in the treatment of sleep apnea or other respiratory disorders. It ensures that the airways remain open by delivering air to the patient at preset pressures via a mask. It is generally used in the fields of pulmonology and sleep medicine.
Quantity Information
The images include a total of 1 Prisma30ST main device, 1 prismaAQUA humidifier unit, 1 power adapter and cable, 1 breathing tube, and 1 headgear along with mask parts.
General Condition
It is observed that the device has been used. The main unit and the humidifier unit are connected. It is understood that the accessories have also been used.
Physical Deformation
There are visible dust accumulations, fingerprints, and superficial scratches on the black plastic casing of the device and especially on the screen surface. Similar contamination and signs of use are visible on the transparent cover of the humidifier unit. No breakage or deep cracks have been detected on the casing.
Mechanical Components
The air outlet port on the front of the device and the humidifier connection points appear to be intact. The water chamber cover of the humidifier unit is in place. The power button appears physically intact. No tearing or breakage has been visually detected on the breathing tube and mask parts.
Electronic Components
The device screen is off; therefore, there is no visual data regarding its electronic functionality. The power button and the electronic panel around the screen maintain their integrity. The power adapter and cables appear physically intact.
Accessories
A gray breathing tube, headgear, and mask silicone are visible with the device. Additionally, there is one power adapter and an electrical cable. There is no information in the images regarding the expiration date of the accessories. There is one air outlet socket and one power input socket on the front face of the device.
Battery Status
It cannot be understood from the images whether the device has an internal battery. No external battery pack is visible.
Label Information
Labels containing technical information such as serial number, lot number, or REF code on the main unit and the humidifier unit cannot be clearly read in the images. Only the brand and model names are legible.
Screen Analysis
The device screen is off. There is dust and contamination on the screen surface.
Size and Compatibility
There is no visual information on the labels regarding the physical dimensions of the device or patient compatibility (adult/pediatric). However, such devices are generally designed for adult patients.
Production Year
The production year of the device cannot be determined from the labels in the images.
Documents
There are no documents such as an invoice, warranty certificate, or user manual in the images.
Usage Duration
No information regarding the total usage hours of the device is visible on the screen or labels.
Existing Faults
There is no clear evidence in the images, such as broken parts or error messages, indicating that the device is faulty.
Potential Fault Risk
The dust and contamination seen on the outer casing and screen of the device indicate that the device is in need of maintenance. However, since no serious wear, rusting, or crushing of the cables is observed, the general condition of the product is good.