Ready For Sale

Whatsapp »
SKU: MB675WOQAC3

Secondhand Sleeptime Plus ST30 N1221006 BPAP ST Device with Humidifier

, , , , , ,

Price: USD$ 215,00 Approx: 9.675,00 TL

Ready For Sale

Don't Want To Buy At This Price?

    Bid


    * We kindly ask you to write your Whatsapp number with the country code so that we can contact you quickly.

    Click once and wait.

    Ask a Question

      Fill in the form below to send us your message. Click the button and wait. We will contact you as soon as possible.


      * We kindly ask you to write your Whatsapp number with the country code so that we can contact you quickly.

      Click once and wait.

      Payment

      No additional fees, full assurance. We provide complete financial and operational security in secondhand medical device trading. For this, we offer the "Secure Payment" service. This free service protects the rights of both parties by securing the buyer's money and the seller's product. The Secure Payment system is a standard assurance mechanism offered by Medbidding. For additional information, review the "services" page.

      There is no cash on delivery order system on the Medbidding platform. For payments to be made by credit card, the product to be purchased must comply with this payment method. You can contact us to get information about this. We would be happy to assist you.

      For payments made outside of Turkiye, you can choose bank transfer, credit card, Western Union or cryptocurrency options. Installment options are not currently available for credit cards other than Turkish banks.

      Shipping

      Free Shipping Conditions

      You can benefit from our FREE SHIPPING campaign for your purchases in this category. Medbidding covers all shipping costs for both the buyer and the seller on orders that meet the conditions below. For all international sales and domestic sales within Turkiye that do not meet these conditions, Medbidding’s standard shipping procedures will apply.

      Conditions

      • The product must be sold for $250 USD or more.
      • Both the buyer and the seller must be located in Turkiye.

      Standard Shipping Conditions

      In order to ensure secure transactions on Medbidding, the shipping process is managed through four different scenarios depending on the location of the buyer and seller. Free shipping is available for some categories. The terms below apply to all categories unless otherwise stated.

      Buyer and Seller in Turkiye

      • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
      • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

      Buyer Outside Turkiye, Seller in Turkiye

      • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
      • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

      Buyer in Turkiye, Seller Outside Turkiye

      • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
      • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

      Buyer and Seller Outside Turkiye

      If there is a local operation center in the seller's country:

      • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
      • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

      If there is no operation center in the seller's country:

      • Technical Inspection: Inspections are performed by our engineers via remote video call.
      • Seller → Buyer: The seller packages the product and sends it directly to the buyer's address. The seller is responsible for this shipping cost.

      Objective AI Report

      Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.

      Report date: 19.02.2026

      SLEEPTIME SLEEPTIME PLUS BPAP ST30 SYSTEM Device Analysis Report

      Device Identification

      The device shown in the visuals is a BPAP (Bilevel Positive Airway Pressure) device used to provide medical respiratory support. The product consists of a main control unit and an integrated heated humidifier unit. Additionally, components such as a carrying bag, air hose, and power adapter are also present in the visuals.

      Brand and Model

      As a result of detailed visual inspection and label analysis, the brand and model information of the device has been identified with 100% certainty. The information located on the bottom and front of the device is as follows:

      • Brand: SLEEPTIME
      • Device Model: SLEEPTIME PLUS BPAP ST30 SYSTEM
      • Humidifier Model: SLEEPTIME PLUS HUMIDIFIER
      • Manufacturer: ELMASLAR A.Ş. (Elmaslar Medikal)

      Originality

      On the labels at the bottom of the device, the serial number, production date, electrical values, and manufacturer information (Elmaslar A.Ş.) are provided in detail and in compliance with standards. CE marks (CE 1984) and the quality of technical printing indicate that the product is an original medical device.

      Areas of Use

      The SLEEPTIME PLUS BPAP ST30 SYSTEM is used to provide bilevel positive airway pressure in patients suffering from respiratory failure (such as COPD, Sleep Apnea, etc.). It is suitable for use by home care patients and in hospital settings. The device supports the patient’s breathing, keeping the airway open.

      Quantity Information

      The set in the visuals contains the following parts in total:

      • 1 BPAP main unit device.
      • 1 Heated Humidifier unit integrated into the device.
      • 1 Original carrying bag.
      • 1 Power adapter and cable.
      • 1 Respiratory tube (circuit).
      • 1 thin air/oxygen tube.

      General Condition and Physical Deformation

      The device is used, but its general condition appears clean. Notable details are as follows:

      • Casing: No significant cracks or fractures were observed on the plastic outer casing. However, there are slight smudges and superficial marks from use around the buttons on the front panel and on the casing.
      • Humidifier Unit: The warning “DİKKAT SU VARKEN CİHAZI TAŞIMAYINIZ” (CAUTION DO NOT CARRY THE DEVICE WHEN THERE IS WATER INSIDE) is present on the water reservoir section on the right side; slight peeling is observed around the edges of this label.
      • Buttons: The navigation wheel on the front panel and two function buttons (Alarm mute and Start/Ramp buttons) are physically intact and in place.
      • Connection Points: The junctions of the devices and the labels on the back appear neat.

      Label Information

      The technical and identification data read from the labels at the bottom of the device are as follows:

      • Main Device Serial Number (SN): T2C18501154
      • Humidifier Serial Number (SN): T2C18501154-1
      • Main Device Power Input: 24 VDC, 2.5A
      • Humidifier Power Input: 100-240 VAC, 50-60 Hz, 70VA Max
      • Reference Standards: CE 1984 is stated.
      • Origin: Although the manufacturer appears as a Turkish company on the label, the phrase “Made in P.R.C” is present.

      Year of Manufacture

      On the labels of both units (Main device and Humidifier), the production date is clearly stated as 07.2018 (July 2018).

      Accessories

      The condition of the accessories accompanying the product is as follows:

      • Carrying Bag: An original bag made of black and gray fabric material is present. No tears are visible, and the zippers appear intact.
      • Hoses: A standard transparent corrugated respiratory hose is present. No dirt accumulation or crushing is apparent inside the hose in the visuals, but replacement may be necessary for hygiene reasons as it is a used product.
      • Power Adapter: A black power adapter is present. Although the cables are somewhat tangled, there is no visible breakage or peeling in their outer insulation.

      Screen Analysis

      The left unit of the device features a colored LCD screen. Since the device is off in the photographs, no error codes, menus, or operating hours information can be displayed on the screen. No deep scratches or cracks are visible on the screen glass.

      Potential Failure Risk

      No serious risk factors (such as a broken casing, severed cable, burn marks, etc.) that would prevent the device from operating are present in the visuals. However, due to the device’s 2018 production date and its status as a used product, the lifespan of its internal turbine motor and the cleanliness of its filters cannot be visually confirmed. In terms of physical integrity, its condition is good.