Sold Out

Whatsapp »
SKU: MBM2IRYMX12

Secondhand Plusmed XT-1 CPAP Device with Humidifier

, , , ,

Price: USD$ 100,00 Approx: 4.500,00 TL

Sold Out

Objective AI Report

Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.

Report date: 21.01.2026

plusMED XT-I Respiratory Therapy Device Analysis Report

Device Identification and Product Description

The product in the image is a medical respiratory device used in airway treatments, especially in the management of conditions such as sleep apnea. The device consists of a main motor unit and a transparent humidifier water tank integrated into its front part. Based on its design, it has been identified as a desktop CPAP or APAP (Automatic Positive Airway Pressure) device suitable for home use.

Brand and Model

Upon examination of the black control panel on the front face of the product, the brand is clearly visible as plusMED. On the panel, in the upper right corner of the screen, the model number XT-I can be read. In light of this information, the product’s brand is plusMED, and its model is the XT-I series.

Originality Assessment

The logo print on the device, button layout, screen placement, and material quality used (ABS plastic body and transparent polycarbonate water tank) indicate that the product is an original plusMED production. No visual evidence of aftermarket or replica production has been found.

Areas of Use

plusMED XT-I is a positive airway pressure device used in the treatment of obstructive sleep apnea (OSAS) patients. Thanks to its front humidifier tank, it aims to prevent dryness in the airways by humidifying the air delivered to the patient. It is generally used in home care settings or hospital sleep laboratories. It is suitable for adult patients.

General Condition and Physical State

The external appearance of the device is in “used” condition. It is understood to be second-hand, based on the signs of use on its surface.

  • Body (Casing): The white-colored upper body of the device has noticeable superficial scratches, friction marks, and black smudges (scuff marks from rubbing). There are signs of dullness on the plastic surface.
  • Cleanliness State: Dust accumulations and dirt residues have been observed at the joints between the black control panel and the white casing, and around the edges of the buttons. Additionally, there is dust accumulation in the indentations on the humidifier tank. Detailed cleaning and hygiene maintenance are required.
  • Humidifier Tank: Although the transparent water tank at the front appears intact, it is presumed to have water stains or lime-scale-like marks on its inner or outer surface. Fine scratches due to use are present on the transparent plastic surface.

Mechanical and Electronic Component Analysis

  • Button Set: The device has 4 control buttons: Menu/Note (top left), Power (bottom left, with green symbol), Up arrow (top right), Down arrow (bottom right). The symbols on the buttons are legible; no physical breakage or collapse is observed.
  • Screen Analysis: A liquid crystal display (LCD) is located on the upper part of the device. Since the device is in the off position in the image, no comment can be made regarding pixel status or screen illumination. However, no deep crack is visible on the screen glass.
  • Sockets and Inputs: A circular output port for attaching the air hose is open on the humidifier tank. No suitable hose is attached here.

Accessories and Quantity Information

A total of 1 unit of the main device (with the water tank attached to the device) is present in the image. The following parts, which are necessary for the product’s operation, are not present in the image:

  • Power adapter and power cable (although a black cable is visible at the back, it cannot be clearly confirmed whether it is the device’s own cable, it has not been counted as part of the device).
  • Respiratory hose.
  • Patient face mask (nasal or full face).
  • Carrying bag.

Potential Malfunction Risk

No major breakage, dent, or electronic damage (burn marks, etc.) that would hinder the device’s operation is visible in the images. However, the used condition of the device and the dust accumulation on it suggest that the filters and water tank have not been cleaned for a long time. This situation could pose a hygiene risk and affect air intake performance. While the risk of mechanical malfunction appears low, filter replacement and general sterilization before use are important for performance.