Ready For Sale
Secondhand Respirox E-20A CPAP Device with Humidifier
Price: USD$ 180,00 Approx: 7.920,00 TL
Ready For Sale
Ask a Question
Payment
No additional fees, full assurance. We provide complete financial and operational security in secondhand medical device trading. For this, we offer the "Secure Payment" service. This free service protects the rights of both parties by securing the buyer's money and the seller's product. The Secure Payment system is a standard assurance mechanism offered by Medbidding. For additional information, review the "services" page.
There is no cash on delivery order system on the Medbidding platform. For payments to be made by credit card, the product to be purchased must comply with this payment method. You can contact us to get information about this. We would be happy to assist you.
For payments made outside of Turkiye, you can choose bank transfer, credit card, Western Union or cryptocurrency options. Installment options are not currently available for credit cards other than Turkish banks.
Shipping
Free Shipping Conditions
You can benefit from our FREE SHIPPING campaign for your purchases in this category. Medbidding covers all shipping costs for both the buyer and the seller on orders that meet the conditions below. For all international sales and domestic sales within Turkiye that do not meet these conditions, Medbidding’s standard shipping procedures will apply.
Conditions
- The product must be sold for $250 USD or more.
- Both the buyer and the seller must be located in Turkiye.
Standard Shipping Conditions
In order to ensure secure transactions on Medbidding, the shipping process is managed through four different scenarios depending on the location of the buyer and seller. Free shipping is available for some categories. The terms below apply to all categories unless otherwise stated.
Buyer and Seller in Turkiye
- Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
- Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.
Buyer Outside of Turkiye, Seller in Turkiye
- Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
- Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.
Buyer in Turkiye, Seller Outside Turkiye
- Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
- Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.
Buyer and Seller Outside Turkiye
- Technical Inspection: Technical inspections are performed by our business partner in the seller's country (where available) or by our engineers via remote video call.
- Seller → Buyer: The seller packages the product and sends it to the buyer's address. The seller is responsible for this shipping cost.
Objective AI Report
Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.
Report date: 14.01.2026
Respirox E-20A System Respiratory Device Analysis Report
Device Identification and Product Components
The product set analyzed in the visuals is a medical respiratory support device system. The set consists of a main control unit and an integrated humidifier unit. The device’s modular structure, separated into two parts (main motor block and water chamber block), is clearly visible in the visuals. Essential components such as the accompanying air hose, nasal mask, power adapter, and user manual are also included in the set.
Brand and Model Information
As a result of detailed examinations, the brand/model information of the device and its accessories has been identified as follows:
- Device Brand: Respirox
- Device Model: E-20A System
- Mask Brand: BMC (The “BMC” logo is clearly visible on the label on the blue head strap.)
- Distributor Information: The phrase “Ece Medikal”, understood to be the Turkish distributor, is present on the user manual.
Areas of Use and Purpose
This device is a CPAP (Continuous Positive Airway Pressure) or automatic pressure adjusting (Auto-CPAP) system. It is generally used in the treatment of Sleep Apnea (OSAS) to keep patients’ airways open during sleep. The device delivers pressurized air to the patient via a hose and mask. The detachable unit next to it is a heated humidifier used to moisturize the delivered air and prevent feelings of dryness. It is designed for adult patients in a home care environment.
General Condition and State
Upon visual inspection, the product appears to be in a clean and well-preserved condition. No yellowing or color changes due to heavy use are noticeable on the silver and dark grey colored outer casing specific to the “Genius” or “Respirox” series. Although it is a second-hand item, it gives the impression of being carefully used or maintained.
Physical Deformation and Mechanical Part Analysis
- Casing: No cracks, deep scratches, or dents have been detected on the plastic casing of the device. Corners and edges are in good condition.
- Connection Points: In Images 2 and 3, the device is shown in two parts (motor and humidifier). The mechanical latches and seating slots that allow these two units to connect appear sturdy. No broken latch piece is present in the image.
- Water Chamber: The lid and general structure of the humidifier’s water tank appear sturdy.
- Hose and Mask: There are no visible kinks or holes in the hose. The mask silicone might be slightly yellowed (which could be due to light reflection, but replacement might be necessary for hygienic reasons), but the mask frame is intact.
Electronic Components and Screen Condition
The LCD screen on the front of the device is in the off position, so it was not possible to analyze whether there were dead pixels or screen illumination issues. No deep scratches or cracks are visible on the screen glass. The three control buttons on the front panel and the central adjustment wheel (knob) are in place and appear physically complete. The gold-colored metal connection pins (on the side surface of the unit on the left in Image 3), which provide electrical transmission between the device and the humidifier, are clean and not bent.
Quantity Information
The total number of items seen as a set in the visuals is as follows:
- 1 Main Device (Motor Unit)
- 1 Heated Humidifier Unit (Attachable to the device)
- 1 Power Adapter (Black)
- 1 Spiral Air Hose
- 1 Nasal Mask (with BMC brand headgear)
- 1 User Manual (Bagged)
- 1 Carrying Bag (Blue/Navy – partially in frame)
Accessories and Consumables
The accessories included in the set are compatible with the device. The power adapter appears suitable for the input on the side of the device. The blue-headed BMC mask has a universal hose input and is suitable for use with this device. The device’s air filter cover is present at the back (Image 2); however, the internal condition of the filter cannot be seen from the outside. Since parts like the mask and hose are personal items for hygienic reasons, it is recommended that a new user replace them.
Documents and Label Information
Next to the device, a “User Manual” is found in its original bag. On the manual:
- Ece Medikal logo,
- Respirox brand logo,
- Respirox E-20A System product code is clearly legible.
The fact that the manual is still in its bag indicates that the device has either been used little or its box contents have been meticulously preserved. Technical labels are present on the back of the device (Image 2), but due to the resolution and angle of the photograph, the serial number (SN) or year of manufacture information cannot be read.
Potential Fault Risk and Evaluation
Based on the analysis of the visuals, no broken, burnt, or severely damaged areas that would prevent the device from operating were found. Particularly, the cleanliness of the connection pins between the motor and the humidifier suggests that electronic communication will be established correctly. As a potential risk, humidifier water chambers may develop scale buildup or leaks over time, but no dense scale layer is visible in the transparent parts in the visual. The product’s physical condition can be categorized as “Very Good / Cleanly Used”.