Objective AI Report
Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.
Report date: 31.07.2026
Report code: 1785480095
MASIMO Rad 97 Patient Monitor Analysis Report
Device and Accessory Identification
The examined images contain one MASIMO Rad 97 model patient monitor and various accessories belonging to this device. The main device has a portable structure. Accessories include a power cable and patient monitoring sensors/cables.
Brand and Model Information
The “MASIMO” brand and “Rad 97” model are clearly written on the front of the device. It is also observed that the device features “MASIMO SET RAINBOW” technology. This information definitively indicates that the device is a MASIMO brand RAD 97 model patient monitor.
Authenticity Assessment
When examining the logo quality, clarity of the labels, and general workmanship details on the device, the impression is that the product is original. No signs of counterfeiting or low-quality workmanship have been observed.
Usage Areas
The MASIMO Rad 97 is a device used for non-invasive patient monitoring. It is primarily designed to measure vital parameters such as oxygen saturation (SpO2) and pulse rate (PR). Thanks to “RAINBOW” technology, it has the potential to monitor additional parameters such as carbon monoxide (CO). This device is suitable for bedside monitoring in hospitals, clinics, emergency departments, and home care environments. The accessories in the image are patient sensors and connection cables compatible with this monitor.
Quantity Information
- One MASIMO Rad 97 main device.
- One power cable.
- One patient sensor/cable in sealed packaging.
- One loose patient sensor/cable.
- Numerous wrapped patient sensors/cables inside a box.
General Status and Physical Condition
The general condition of the device appears to be good. No significant scratches, dents, cracks, or discoloration have been detected on its casing, screen area, or other external surfaces. There may be slight dust or dirt on the surfaces.
Mechanical and Electronic Component Inspection
There are no visible issues with the mechanical components, buttons, ventilation grille, or connection ports of the device. All parts are intact and in place. Since the device screen is off, a visual analysis of the electronic components’ operational status could not be performed. Internal electronic components are not present in the images.
Condition of Accessories
A three-pronged power cable is included with the device. Additionally, there is a patient sensor/cable in a closed and sealed package labeled “Total Patient Monitoring Accessories.” This package bears a “QC PASS” mark. Another patient sensor/cable with red and white connectors is also visible. There are numerous similar patient sensors/cables inside a box. There is a multi-pin socket input on the left side of the device, which appears clean. The expiration dates of the accessories are not clearly readable in the images.
Battery Status
The internal or external battery of the device is not visible in the images. Therefore, no comments can be made regarding the capacity or physical condition of the battery.
Label Information Details
The label on the patient sensor/cable in the sealed package contains the following information:
- Serial Number (S/N): This number is a unique identifier for each product or accessory. It ensures the traceability of the product for production tracking, warranty services, and potential recall situations.
- REF Code: This code indicates the model or part number of the product or accessory. It is critical for identifying the correct spare part or compatible accessory.
Screen Analysis
The device screen is in the off state. No text, warning messages, menus, or measurement values are visible on the screen.
Size and Compatibility
The device has a compact size that can be easily gripped by an adult’s hand. This indicates that the device is easily portable and suitable for use in limited spaces such as bedside areas. There is no specific information in the images regarding the compatibility of the patient sensors, but generally, such devices can be used with sensors suitable for different age groups (adult, pediatric, neonatal).
Year of Manufacture
There is no direct information regarding the year of manufacture on the device or accessories in the images. The modern design and clean, well-maintained appearance of the device suggest that it may have been manufactured recently.
Documents
There are no invoices, warranty certificates, user manuals, or other documents belonging to the device in the images.
Usage Duration
No information regarding usage hours or total operating time has been detected on the device screen, labels, or any documents in the images.
Current Fault Status
No clear evidence of a fault such as a broken part, error message, severed cable, or missing component has been observed on the device or its accessories in the images.
Potential Fault Risk
No conditions that could pose a potential fault risk, such as severe wear, rust, or cable crushing, have been detected on the device casing, screen, or accessories. The general condition of the device is good.