Ready For Sale
Defective Secondhand Aloka SSD-1700 Ultrasound Machine
Price: USD$ 1.000,00 Approx: 45.000,00 TL
Ready For Sale
Ask a Question
Payment
No additional fees, full assurance. We provide complete financial and operational security in secondhand medical device trading. For this, we offer the "Secure Payment" service. This free service protects the rights of both parties by securing the buyer's money and the seller's product. The Secure Payment system is a standard assurance mechanism offered by Medbidding. For additional information, review the "services" page.
There is no cash on delivery order system on the Medbidding platform. For payments to be made by credit card, the product to be purchased must comply with this payment method. You can contact us to get information about this. We would be happy to assist you.
For payments made outside of Turkiye, you can choose bank transfer, credit card, Western Union or cryptocurrency options. Installment options are not currently available for credit cards other than Turkish banks.
Shipping
Standard Shipping Conditions
In order to ensure secure transactions on Medbidding, the shipping process is managed through four different scenarios depending on the location of the buyer and seller. Free shipping is available for some categories. The terms below apply to all categories unless otherwise stated.
Buyer and Seller in Turkiye
- Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
- Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.
Buyer Outside Turkiye, Seller in Turkiye
- Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
- Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.
Buyer in Turkiye, Seller Outside Turkiye
- Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
- Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.
Buyer and Seller Outside Turkiye
If there is a local operation center in the seller's country:
- Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
- Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.
If there is no operation center in the seller's country:
- Technical Inspection: Inspections are performed by our engineers via remote video call.
- Seller → Buyer: The seller packages the product and sends it directly to the buyer's address. The seller is responsible for this shipping cost.
Objective AI Report
Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.
Report date: 13.04.2026
Report code: 1776074587
Aloka ProSound Ultrasound Device Analysis Report
Device Identification and Usage Areas
The product in the image is an ultrasonography (ultrasound) device integrated into a wheeled transport cart (stand). These devices are used for diagnostic purposes in various medical specialties such as radiology, obstetrics and gynecology, cardiology, and urology to visualize internal organs, tissues, and blood flow in the human body.
Brand and Model
The ALOKA brand is clearly legible on the lower part of the monitor frame. The ProSound and DynaView II inscriptions are located on the upper right corner of the control panel. Based on this visual evidence, it has been determined that the device is an Aloka ProSound series ultrasound machine.
Quantity Information
- 1 unit of ultrasound main unit and monitor integrated into a wheeled stand
- 2 units of ultrasound probes
General Condition and Physical Deformation
The device is in a used condition. There is significant color fading and yellowing on the monitor casing, the control panel, and the plastic components where the probe holders are located. Dirt and staining are observed on the surface of the control panel, particularly around the keys, trackball, and adjustment knobs. No visible breaks, dents, or cracks have been detected on the outer casing or the screen of the device.
Mechanical and Electronic Components
Structurally, the device features an older generation CRT (cathode ray tube) monitor. The monitor is in a powered-off state. The control panel includes a fully equipped alphanumeric keyboard, a trackball in the center, vertical adjustment sliders on the right side, and various rotary adjustment knobs. The mechanical keys and knobs are physically in place, and no missing parts are apparent. A four-wheeled transport system and a footrest section are located at the bottom of the device.
Accessories and Hardware
There are two ultrasound probes located in the probe holder slots on the right side of the device. One of the probes is in the form of an endocavitary probe with a long handle structure. The other probe is in the form of a standard surface imaging probe. The cables belonging to the probes hang down towards the bottom of the device. There are several sheets of white paper and a small black hardware component on the bottom shelf of the device.
Authenticity
Considering the placement of the brand logos on the device, the professional layout of the control panel, and the general industrial casing structure, it is assessed that the product is an original medical device.
Potential Failure Risk
The intense yellowing of the plastic components and the contamination on the control panel indicate that the device has been in use for a long time and is an aged unit. The fact that the probe cables hang freely and are positioned close to each other may create a risk of wear at the cable bases due to bending over time. No clear physical damage, severed cables, or broken parts that would prevent the device from operating have been observed in the image.