Objective AI Report
Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.
Report date: 15.09.2026
Report code: 1789481005
DEWERT MCL II CARE Control Unit Analysis Report
Device Identification and Basic Information
The product examined in the images is a control unit designed for medical motion systems. The main body of the device is made of rigid plastic material in a light gray color. The brand of the product is DEWERT, and the model is clearly stated on the label as MCL II CARE.
- Device Identification: It is a control unit used in hospital beds and similar medical motion systems.
- Brand and Model: DEWERT MCL II CARE
- Authenticity: Upon examination of the product labels, logo quality, serial number, and standard symbols, it appears to be original.
- Quantity Information: There is a total of 1 control unit in the images.
Usage Areas and Compatibility
This unit is used to manage the movement of motors in hospital beds and medical support equipment. Thanks to the port structures on it, it is compatible with hand controls and motor connections.
- Usage Areas: It is preferred in hospital and home care environments to control bed movements.
- Size and Compatibility: There is no direct measurement information in the images, but it is in a form compatible with standard medical bed frame slots.
General Condition and Physical State
There are signs of use and slight surface abrasions on the outer casing of the device. Physical deformation and mechanical component details are listed below.
- General Condition: It is in used and functional condition.
- Physical Deformation: Slight dirt, dust accumulation, and marks due to friction are visible on the body surface. No cracks or breaks have been detected.
- Mechanical Components: The connection tabs and port slots are in place; there is no visible mechanical breakage.
Electronic Components and Connection Points
The electronic infrastructure of the device is supported by an external power supply and multiple port inputs. Socket structures and electrical values have been read from the label.
- Electronic Components: It features a multi-pin hand control port and color-coded motor connection socket slots.
- Battery Status: There is no internal or external battery in the images; it operates directly on mains electricity.
- Accessories: There are no external cables or adapters in the images. Black covers protecting the socket inputs are present.
Label, Text Inventory, and Screen Analysis
There are labels containing technical data on the device body. A screen component is not present in this type of device.
- Label and Text Inventory: The expressions read on the label are as follows: MCL II CARE, 68385, 100V – 240V ~ 50/60Hz, max. 3.15A, Intermittent Operation 2min/18min, Prod. Date: 39/13, Serial-No.: H494334 0228, IP66, CE, TUV, cURus, N13283, DEWERT A Phoenix Mecano Company. These data indicate the device’s electrical consumption limits, duty cycle signals, and protection class.
- Screen Analysis: There is no screen on the device.
Production and Documentation Information
The production period of the product is understood from the label data on it. There are no documents accompanying the device in the images.
- Production Year: According to the “Prod. Date: 39/13” expression on the label, it was produced in the 39th week of 2013.
- Documents: There are no invoices, warranty certificates, or user manuals in the images.
- Usage Duration: There is no counter or data on the device showing the total operating hours.
Fault and Risk Assessment
No clear evidence of a fault was found during the examination based on visual evidence.
- Current Fault: There is no evidence of an active fault such as a broken part, error message, or severed cable in the images.
- Potential Fault Risk: Apart from superficial abrasions on the body surface, no serious wear or risk has been observed; its condition is medium-to-good.