Objective AI Report
Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.
Report date: 17.10.2025
Primedic Accu M240 Battery Analysis Report
Overview and Product Description
The visuals show one battery, understood to belong to a medical device. Based on its specially designed structure and the label stating “Only for use with PRIMEDIC Defi-Monitor,” the product is a power source manufactured for Primedic brand defibrillator devices. It has an orange, rectangular form. The total number of products in the visuals is limited to one (1).
Brand and Model Identification
The brand of the product has been identified as Primedic, clearly written on its casing. The label also indicates that the manufacturer is Metrax GMBH. The type and model of the product is the code M240, clearly visible in the “Type” section of the label.
Physical Condition and Deformation Assessment
The general condition of the battery is used. On the surface of its orange plastic casing, there are slight scratches, dirt, and small stains, presumed to be due to use. However, no serious deformation such as cracks, fractures, dents, or damage that would compromise the battery’s integrity has been observed on the casing. The battery’s charging and connection terminals appear visually sound.
Battery and Technical Information
This product is an external and rechargeable battery pack. According to the label information, the battery features Nickel-Cadmium (NiCd) technology and offers 14.4VDC voltage with a 1.3Ah capacity. Visually, there are no signs of swelling, leakage, or physical damage on the battery itself. The label contains multi-language warnings stating that an empty battery should be charged for at least 45 minutes while the defibrillator is turned off.
Label Information
The label on the back of the product contains the following information:
- Brand: Primedic (Manufacturer: Metrax GMBH)
- Model/Type: M240
- Serial Number (SN): A226A01784
- Production Date (P-Date): 04/14 (April 2014)
- Technical Specifications: 14.4VDC / 1.3Ah / NiCd
- Compatibility: Only for use with PRIMEDIC Defi-Monitor.
- Protection Class: IPX1
- Origin: Made in Germany
Potential Failure Risk and Conclusion
Visually, there are no cracks, fractures, or critical damage on the product. However, it is notable that the production date on the label is April 2014. Nickel-Cadmium (NiCd) type batteries are known to have a specific lifespan, and their performance can naturally decline over time. Therefore, the battery’s current charge retention capacity and overall performance may have been affected by the time elapsed since its production date. While a definitive comment on the battery’s functionality cannot be made, its physical condition can be stated as good.