Ready For Sale

Whatsapp »
SKU: MB9S845ZRBJ

Secondhand SL-MTI MH2630-136A-R PM Servo Motor

Price: USD$ 1.000,00 Approx: 44.000,00 TL

, , , ,

Ready For Sale

Don't Want To Buy At This Price?

    Bid


    * We kindly ask you to write your Whatsapp number with the country code so that we can contact you quickly.

    Click once and wait.

    Ask a Question

      Fill in the form below to send us your message. Click the button and wait. We will contact you as soon as possible.


      * We kindly ask you to write your Whatsapp number with the country code so that we can contact you quickly.

      Click once and wait.

      Payment

      No additional fees, full assurance. We provide complete financial and operational security in secondhand medical device trading. For this, we offer the "Secure Payment" service. This free service protects the rights of both parties by securing the buyer's money and the seller's product. The Secure Payment system is a standard assurance mechanism offered by Medbidding. For additional information, review the "services" page.

      There is no cash on delivery order system on the Medbidding platform. For payments to be made by credit card, the product to be purchased must comply with this payment method. You can contact us to get information about this. We would be happy to assist you.

      For payments made outside of Turkiye, you can choose bank transfer, credit card, Western Union or cryptocurrency options. Installment options are not currently available for credit cards other than Turkish banks.

      Shipping

      Standard Shipping Conditions

      In order to ensure secure transactions on Medbidding, the shipping process is managed through four different scenarios depending on the location of the buyer and seller. Free shipping is available for some categories. The terms below apply to all categories unless otherwise stated.

      Buyer and Seller in Turkiye

      • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
      • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

      Buyer Outside of Turkiye, Seller in Turkiye

      • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
      • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

      Buyer in Turkiye, Seller Outside Turkiye

      • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
      • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

      Buyer and Seller Outside Turkiye

      • Technical Inspection: Technical inspections are performed by our business partner in the seller's country (where available) or by our engineers via remote video call.
      • Seller → Buyer: The seller packages the product and sends it to the buyer's address. The seller is responsible for this shipping cost.

      Objective AI Report

      Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.

      Report date: 30.12.2025

      SL-MTI MH2630-136A-R PM Servo Motor Analysis Report

      Device Identification and Product Description

      The analyzed product is a PM Servo Motor (Permanent Magnet Servo Motor) unit manufactured to provide precise motion control in industrial and medical devices. According to the data obtained from the visuals, this motor is not a standard motor for general use, but a high-specification spare part specially manufactured according to specific medical device standards (GE Medical Specification).

      The product has a cylindrical structure; the middle part of its body is black, while the bottom and top covers are metallic silver. The motor shaft is clearly visible at the bottom. On its sides, there are black plastic socket/connector structures used for mounting and electrical connections.

      Brand and Model Information

      Based on the information on the product’s original factory label, the brand and model details are as follows:

      • Brand: SL-MTI (SL-MTI Torque Systems markings are present on the label)
      • Model: MH2630-136A-R
      • Product Type: PM SERVO MOTOR
      • Reference Customer Code (GE Part No): 46-282360P1 (specified in the Cust # line)

      This product was manufactured by SL-MTI with special certification for GE Medical. The phrase “MOTOR PASSED GE MEDICAL SPECIFICATION” on the label proves this special manufacturing.

      Technical Label and Identifying Data

      Technical data and identifying codes read from the label on the device body are listed below:

      • Serial Number (Ser. No): 1849130074
      • Customer Number (Cust #): 46-282360P1
      • File Number (File No): E163094
      • Insulation Class: Class F
      • Certifications: CE mark, cRUus (UL Component Recognition) mark are present.
      • Environmental Standard: RoHS compliant (Green RoHS label is present).

      Warning and Safety Labels

      On the motor body, there is a prominent “WARNING” label with black text on an orange background. The warnings on this label are as follows:

      • Magnetic Hazard: “CONTAINS FERROUS MATERIAL”. Given it contains strong magnets, the warning “Personal injury could result due to strong attraction to magnet” is present.
      • Service Warning: It is stated that service documentation should be consulted before servicing.
      • Label Bottom Code: Another code, 46-282756P1, is located in the bottom right corner of the warning label.

      Areas of Use

      The “GE MEDICAL SPECIFICATION” phrase on the product indicates that this motor is specifically used in GE Healthcare (General Electric) brand medical imaging or diagnostic devices. PM Servo Motors are generally used in the following areas:

      • In the moving parts of medical imaging systems (CT, MR, X-ray) (such as Gantry or patient table movement).
      • In robotic medical applications requiring high precision and torque.

      Physical Condition and Deformation Analysis

      The general cosmetic condition of the product appears clean and undamaged visually:

      • Body: No deep scratches, dents, rust, or impact marks were observed on the metal cylindrical body. The black body coating is intact.
      • Labels: All technical and warning labels are present on the product, intact, and 100% readable. There is no tearing or fading.
      • Mechanical Parts: The motor shaft (spindle) at the bottom of the visual appears clean, showing no signs of rust or oxidation.

      Electronics and Connection Assembly

      The black plastic module seen on the side of the motor appears to house electrical connection terminals or encoder outputs. No cracks or breaks were detected in the plastic components. Although cable ends or socket inputs could not be examined in detail due to the viewing angle, there is no anomaly in the visible structure.

      Originality and Origin

      The product is an original SL-MTI production due to its label quality, logo printing, the presence of CE/UL certification marks, and specific GE part codes. A “Torque Systems” website reference and a USA (United States) address (partially legible) regarding the manufacturer’s address are visible on the label. The product is a 100% original OEM part.

      Quantity Information

      The total number of products analyzed in the visual is 1 unit.

      General Assessment

      The product appears to be in very good physical condition. The cleanliness of its labels and the shine of the metal surfaces suggest that the device has either been used sparingly or has been very well preserved. There is no severe damage, breakage, or deformation (swelling, burn marks, heavy corrosion) visually indicating a potential risk of malfunction. However, as it is a technical component, its electromechanical functionality should be tested. The device can be considered a critical component for GE-compatible medical systems in the second-hand/used spare parts market.