Objective AI Report
Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.
Report date: 01.09.2026
Report code: 1788256257
SÜNGEN Oxygen Regulator Analysis Report
Device Identification and Product Identity
The device in the image is an oxygen regulator that connects to medical oxygen cylinders to reduce the pressure of the gas delivered to the patient and adjust the flow rate. The product body is metallic gray in color and features two round pressure and flow gauge dials. The small gauge at the top indicates the pressure inside the cylinder, while the large gauge at the bottom shows the amount of flow provided to the patient. The brand logo and technical values are present on the body.
Regarding brand information, the SÜNGEN logo and text are present on the dial faces. There is no model code visible in the image.
General Condition and Physical State
The general condition of the device is good, and it has a clean appearance. There are no scratches, dents, cracks, rust, or discoloration on the metallic outer casing or the metal frames surrounding the dials. No dirt or dust accumulation has been observed on the surface.
Mechanical and Electronic Components
The flow control valve, cylinder connection screw, and outlet nipple, which are among the mechanical parts, are in place and functioning properly. The threaded connections and the adjustment knob on the metallic body appear mechanically clean and functional. Since the device operates entirely on mechanical principles, it does not contain any electronic components or screens.
Authenticity and Quantity Information
The clarity of the logo prints within the dials, the quality of the metal craftsmanship, and the printing quality of the symbols indicate that the product is original. The total quantity of the product in the image is one oxygen regulator, and no other accessories or parts are present.
Usage Areas and Compatibility
This device is used to manage oxygen therapy for individuals receiving respiratory support with oxygen cylinders in home care, hospitals, and emergency medical services. It has a standard inlet connection compatible with medical oxygen cylinders.
Accessory and Battery Status
There are no boxes, cables, adapters, or additional spare parts in the image. As the device is a purely mechanical pressure reducer and flow regulator, it does not contain internal or external batteries.
Label and Text Inventory
The texts and symbols read in the image are as follows:
- On the upper dial: 100, 200, 300, 315 values, bar and OXYGEN texts, O2 symbol, and SÜNGEN logo are present. These texts and numbers allow for monitoring the remaining pressure inside the cylinder in bar units.
- On the lower dial: 0, 5, 10, 15 values, l/min and OXYGEN texts, O2 symbol, ORIFICE 0.65mm statement, a prohibition sign symbol, and SÜNGEN logo are found. The l/min value here indicates the oxygen flow rate in liters per minute provided to the patient.
- There are red-colored directional arrow labels on the adjustment screw at the bottom connection part.
Dimensions, Compatibility, Production Year, and Documents
There is no numerical measurement information regarding the physical dimensions, weight, or user body compatibility of the device in the images. There is no information regarding the production year, serial number, lot number, or expiration date on the labels or the dial. No written documents such as invoices, warranty certificates, or user manuals are present in the images.
Usage Duration, Existing Faults, and Potential Risks
There is no operating hour or counter information available regarding how long the device has been used. No evidence of any malfunction such as broken parts, detached or missing components was found during the visual inspection. Since no wear, excessive rust, or deformation was observed on the casing, no potential risk of failure has been detected; the condition of the device is sound.