Secondhand Dragon DW-ST003A Stair Climber

SKU: MBA417W5892

Ready For Sale

, , , , ,

Medbidding Engineers Verify

Secure Payment System

Price: USD$ 930,00 Approx: 43.710,00 TL
Bid

Objective AI Report

Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.

Report date: 21.08.2026
Report code: 1787321040

Tracked Patient Transport Lift Analysis Report

Device Identification and Credentials

The product in the images is a tracked patient transport lift used in emergency and patient transfer processes. The main body of the device consists of yellow and black metal profiles. Since no brand or model text is readable from the images, brand and model information has not been included in the report.

Usage Areas and Purposes

This product is used for transporting patients with limited mobility or elderly individuals down and up stairs, as well as for transport on flat surfaces. It is particularly preferred in hospitals, ambulance services, emergency response teams, and home care settings.

Quantity Information

The images include one main tracked transport lift, one external battery, one charging adapter, and safety belts attached to the device.

General Condition

The device is in generally good condition. Photos taken in both open and closed positions show that the mechanical folding and unfolding components are in place. It is understood that the product is not new and bears slight signs of use.

Physical Deformation

There is a noticeable label residue and discoloration on the yellow left vertical metal body profile of the device. Apart from this, no major cracks or fractures have been observed on the body in general.

Mechanical Components

The black track belts, transport wheels, folding footrest arms, and pushing handles are in place. The locking mechanisms and red release latches appear functional.

Electronic Components and Battery Status

There is a control panel with a digital display on the upper pushing handle of the device. The panel features speed adjustment buttons, a battery capacity indicator, and an on/off button. An external black battery box is present on the seat area. The swelling or leakage status of the battery cannot be clearly seen from the outside; however, it is resting freely on the seating surface.

Accessories

Black safety belts integrated into the seat and back area are present. There is a black main battery on the seat and a wired adapter used to charge the battery. Socket inputs are located on the control panel.

Label and Text Inventory

The texts read in the images are as follows: The upper control panel features Battery Capacity, Speed, and plus/minus directional buttons. On the upper frame of the back section, there is a PULL inscription and a directional arrow in black letters on a yellow background. These inscriptions indicate that the device’s locking mechanism is opened by pulling.

Screen Analysis

The control panel screen is in the off state. There are graphic areas on the screen showing battery level and speed levels; however, no values are readable as it is not active.

Dimensions and Compatibility

There is no official label in the images indicating the dimensions or weight of the device. It is in the dimensions of a standard patient transfer and stair-climbing lift.

Production Year

There is no production year information on the labels or metal surfaces in the images. Since a periodic inference cannot be made due to the design and material structure, the production year could not be determined.

Documents

There are no invoices, warranty certificates, user manuals, or any printed documents in the images.

Usage Duration

There is no counter data regarding total operating hours or usage duration on the device’s screen or labels.

Existing Faults

There is no evidence of an active fault such as a broken cable, broken carrier track tooth, or an error message in the images.

Potential Fault Risk

Except for the surface coating deformation and label residue on the yellow body profile, no serious wear risk has been observed. Its general condition is sound.