Ready For Sale
Secondhand Tepa Stress ECG Device
Price: USD$ 5.000,00 Approx: 225.000,00 TL
Ready For Sale
Ask a Question
Payment
No additional fees, full assurance. We provide complete financial and operational security in secondhand medical device trading. For this, we offer the "Secure Payment" service. This free service protects the rights of both parties by securing the buyer's money and the seller's product. The Secure Payment system is a standard assurance mechanism offered by Medbidding. For additional information, review the "services" page.
There is no cash on delivery order system on the Medbidding platform. For payments to be made by credit card, the product to be purchased must comply with this payment method. You can contact us to get information about this. We would be happy to assist you.
For payments made outside of Turkiye, you can choose bank transfer, credit card, Western Union or cryptocurrency options. Installment options are not currently available for credit cards other than Turkish banks.
Shipping
Standard Shipping Conditions
In order to ensure secure transactions on Medbidding, the shipping process is managed through four different scenarios depending on the location of the buyer and seller. Free shipping is available for some categories. The terms below apply to all categories unless otherwise stated.
Buyer and Seller in Turkiye
- Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
- Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.
Buyer Outside Turkiye, Seller in Turkiye
- Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
- Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.
Buyer in Turkiye, Seller Outside Turkiye
- Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
- Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.
Buyer and Seller Outside Turkiye
If there is a local operation center in the seller's country:
- Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
- Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.
If there is no operation center in the seller's country:
- Technical Inspection: Inspections are performed by our engineers via remote video call.
- Seller → Buyer: The seller packages the product and sends it directly to the buyer's address. The seller is responsible for this shipping cost.
Objective AI Report
Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.
Report date: 25.02.2026
Kardiosis Tepa ars-EFOR ES 5230 Cardiac Stress Test System Analysis Report
Device Identification
The examined visuals show a system consisting of a medical treadmill and a control unit used for exercise electrocardiography (ECG) tests in cardiology clinics. The system comprises one motorized treadmill, one electronic control unit, computer hardware (monitor, mouse, keyboard), and a support stand system. Additionally, patient preparation equipment used with the system is available.
Brand and Model Information
Upon examination of the labels and logos on the product, the device’s identification information has been determined as follows:
- Main Brand: Kardiosis (Tepa A.Ş.)
- System Series: ars-EFOR
- Model Code: ES 5230 (Indicated on the label on the same line as S/N, refers to the device’s type model).
- Manufacturer: Tepa A.Ş. (Manufactured in Ankara/Turkey).
- Monitor Brand: Izoly
- Mouse Brand: hp
Label and Technical Data Analysis
The following technical data has been listed, read from the metallized label located on the device’s rear panel:
- Serial Number (S/N): 0231 ES 5230
- Safety Class: SINIF 1 – BF TIPI / CLASS 1-BF TYPE
- Power Values (Mains): 220V / 50 Hz, 500 VA
- Manufacturer Address: Tepa A.Ş. ANKARA/TÜRKİYE
- Operating Conditions: +5 to +45 degrees Celsius ambient temperature, maximum 95% humidity.
Authenticity Status
The “kardiosis” embossed logos on the treadmill casing, the prints on the control panel, and the Tepa A.Ş. label on the back of the device prove it to be original factory production. The label craftsmanship and typesetting are in line with original OEM standards. No signs of subsequently applied stickers or fake labels are observed.
Physical Condition and Exterior Casing
The black plastic front cover of the treadmill (the section with the “kardiosis” logo) shows superficial dust and slight scuff marks. The cream-colored metal casing of the control box appears sturdy, with no dents or deep scratches detected. There may be some dulling of the paint on the black frame and handrails due to use, but no significant signs of rust are evident.
Control Unit and Electronic Components
The front panel of the desktop control unit features two separate digital segment displays showing “SPEED (km/h)” and “INCLINE (%)” values. The keypad on the panel (Manual, Automatic, Start, Stop) appears robust, but the tactile response of the buttons cannot be determined from the visual. The readability of the text on the panel is complete, with no fading. The ventilation grilles on the sides of the casing are open.
Mechanical Components and Running Surface
The dullness on the treadmill’s belt (running surface) indicates that the product has been used. Fraying or tearing at the edges of the belt cannot be discerned from the visual. The mechanical handrails and connection screws are in place.
Accessories and Connection Units
The side units displayed with the system are as follows:
- Patient Cables: A bundle of white ECG/trigger cables hangs on the rack next to the device. No breakage is visible on the cable ends and connector blocks, but yellowing is present.
- PC Equipment: An Izoly brand monitor and a standard keyboard-mouse set are located on the system desk. The computer case is positioned in the lower compartment of the desk.
- Safety Belts: A black, hook-and-loop (velcro) safety/patient restraint belt attached to the treadmill is hanging. The stitching appears robust.
- Electrical Connection: The power cable is plugged into a standard IEC input. There is no breakage in the cable entry socket, and the screws are not rusted.
- Medical Consumables Cart: To the left of the system, a wheeled shelving unit containing materials (alcohol, cotton, etc.) used for pre-stress test preparation is present.
General Condition Assessment
The device is in “Second-Hand / Used” condition. Based on its general appearance, it is observed to have come from an active clinical environment and to maintain its operational integrity. No serious damage (broken screen, dented casing, severed cable) is found in the visuals.
Areas of Use
This device is used in Cardiology outpatient clinics and hospitals for “Stress Test” applications. It is suitable for use in the diagnosis of coronary artery disease, investigation of the relationship between arrhythmias and exertion, and cardiac rehabilitation processes.
Notification of Potential Malfunction Risk
No critical malfunction findings are present in the visuals. However, as the device is used, internal mechanical details such as the condition of the treadmill motor brushes and belt tension are outside the scope of visual analysis. Oxidation that may occur over time at the ends of the ECG cables could affect signal quality. The device exhibits a physically clean and tidy appearance.









