Sold Out

Whatsapp »
SKU: MB37VEXT9TZ

Secondhand LZHZXY SXT-5A Suction Device

, , , , ,

Price: USD$ 20,00 Approx: 900,00 TL

Sold Out

Objective AI Report

Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.

Report date: 14.11.2025

GHA SXT-5A Aspirator Device Analysis Report

Product Description and Intended Use

The product in the image is a portable medical aspirator device with a white and blue casing. Such devices are typically used to clear secretions like mucus, phlegm, or other fluids accumulated in patients’ airways by suctioning them out. The carrying handle on it facilitates the device’s mobile use. The device is designed to maintain and relieve airway patency for patients, especially in emergency situations, home care, and hospital settings.

Brand and Model Information

During a detailed examination of the device, it was determined that the brand is GHA and the model is clearly legible as SXT-5A. This information was confirmed from the logo and model inscription on the front of the device.

Quantity Information

The images show the following components:

  • 1 GHA SXT-5A main aspirator unit
  • 1 transparent collection jar and lid system
  • 1 bacterial filter
  • 1 set of connection tubes
  • 1 power cable

Overall Condition Assessment

The product is generally in a used condition. Although its white plastic casing is generally in good condition, slight discoloration and soiling are observed due to use over time. Yellowing and discoloration are present, especially in some parts of the transparent tubes. This indicates that the device has been actively used before.

Physical Deformation and Cosmetic Condition

No significant cracks, breakages, or severe dents were detected on the device’s casing. However, there are superficial scratches and minor stains on the surface due to use. The carrying handle is secure and in place. The connection tubes appear functional, but they are aesthetically the most worn parts and may need to be replaced for hygiene reasons.

Mechanical and Electronic Component Analysis

The analog negative pressure gauge and vacuum adjustment knob on the device’s front panel are physically in sound condition. The gauge glass is transparent and legible. No breakages are observed in the blue ventilation grilles at the bottom of the device. The power cable and plug, as far as visible in the image, do not show physical damage.

Accessory Assessment

The device is seen with the essential accessories required for its operation. The collection jar and its lid feature an overflow prevention system. A bacterial filter is present on the tube leading from the jar to the main unit. The connection ends of the tubes are in place, but the overall condition and color of the tubes indicate long-term use.

Technical Details and Label Information

On the pressure gauge located on the front panel of the device in the image, the inscription NEGATIVE PRESSURE is visible along with the units mmHg and kPa. The model number of the device, SXT-5A, is clearly legible. No detailed production label containing a serial number, REF code, or lot number is present in the images.

Potential Risk Assessment

The product in the image appears to be in working condition concerning its mechanical and electronic components. There are no visible breakages or faulty parts. However, the most significant element that could be considered a potential risk is the yellowed and used tubes and filter. It is advisable to replace such disposable or regularly replaceable medical consumables for hygiene and efficient operation of the device. This situation is a standard maintenance requirement for used medical devices rather than an existing malfunction.