Objective AI Report
Disclaimer: I am Medbidding AI. I am an unbiased AI agent. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.
Report date: 13.10.2026
Report code: 1791899647
Carl Zeiss S5 OPMI MD Surgical Microscope Analysis Report
Device Identification and Credentials
As a result of the examination of the images, it has been determined that the device is an integrated surgical microscope system consisting of a main body, a support stand, an optical head, and a foot control pedal. The brand and model information of the device has been clearly read from the labels and the inscriptions on it.
- Brand and Model: Carl Zeiss Stativ S5 and OPMI MD
- Authenticity: Considering the original brand logos, label quality, type plates, and craftsmanship details, it is observed that the product is original.
Usage Areas and Compatibility
This device allows for detailed examination of anatomy by providing high magnification and illumination during surgical operations and microsurgical procedures. It is generally suitable for use in otorhinolaryngology, neurosurgery, ophthalmology, and plastic surgery branches.
Quantity Information
- The images show one main support stand, one surgical microscope optical head, and one foot control panel.
- The system is located as a single unit with its interconnected components.
General Status and Physical Condition
The device is in used condition, but its general condition is clean. The overall structure of the metal and plastic parts has been preserved.
- Physical Deformation: There is slight dust and minor stains on the body due to normal use, but no deep scratches, dents, cracks, or color fading that would hinder the device’s function have been observed.
- Mechanical Parts: The articulated structure of the support arms, adjustment knobs, wheeled base mechanism, and moving parts are visually in place, and no mechanical issues are apparent.
Electronic and Electrical Specifications
The device’s electronic control panel, switch, and connection ports are clearly visible in the image.
- Electronic Components: The power switch and power outlets on the control panel are in place.
- Battery Status: There is no internal or external battery in the images; the device operates on mains electricity.
- Accessories: The floor-type foot control panel connected to the device, power connection cables, and eyepieces on the optical head are present. There is no screen visible, and the system does not include a screen.
Label and Inscription Inventory
The labels in the image and the inscriptions on them have been read in full:
- Main Label Information: Carl Zeiss, Stativ S5, 305912, 277622, 115 V, 230 V, 100…125 V, 220…240 V, 50…60 Hz, 200 VA, Risk. Class 2G, C 22.2 No125, CE mark, risk class symbol with human figure.
- Inscription on Power Port: max.12V 100W
- Inscriptions on Optical Head: Carl Zeiss, OPMI MD, 12,5x/18 B, 0,4, CENTRE
- Meaning: These technical values specify the operating voltage ranges, power consumption, compatible electrical frequency, and maximum limits of the illumination lamp, ensuring a safe electrical connection.
Dimensions, Compatibility, and Production Information
- Dimensions and Compatibility: There is no direct measurement information in the images, but due to its stand-based structure, it is of a size suitable for bedside use in an operating room environment.
- Production Year: There is no clear production year printed on the labels in the images; however, the device’s design and type label format indicate industrial production standards from past years, and an exact production year cannot be determined.
- Documents: There are no invoices, warranty certificates, or printed user manuals in the images.
- Usage Duration: There is no counter or digital display on the device showing the operating hours or total usage time.
Fault and Risk Assessment
- Existing Fault: There is no clear evidence of a fault such as a broken part, severed cable, or error message in the images.
- Potential Fault Risk: No serious crushing of the cables exposed to the external environment or rusting on the casing has been observed in the image; the general condition is good.