Sold Out

Whatsapp »
SKU: MB93THBMQ3G

Secondhand GE Logiq 180 Ultrasound Machine

Price: USD$ 1.800,00 Approx: 77.400,00 TL

, , , ,

Sold Out

Don't Want To Buy At This Price?

Sorry. This product has been sold. You cannot bid. Please check out other products.

Ask a Question

    Fill in the form below to send us your message. Click the button and wait. We will contact you as soon as possible.


    * We kindly ask you to write your Whatsapp number with the country code so that we can contact you quickly.

    Click once and wait.

    Payment

    No additional fees, full assurance. We provide complete financial and operational security in secondhand medical device trading. For this, we offer the "Secure Payment" service. This free service protects the rights of both parties by securing the buyer's money and the seller's product. The Secure Payment system is a standard assurance mechanism offered by Medbidding. For additional information, review the "services" page.

    There is no cash on delivery order system on the Medbidding platform. For payments to be made by credit card, the product to be purchased must comply with this payment method. You can contact us to get information about this. We would be happy to assist you.

    For payments made outside of Turkiye, you can choose bank transfer, credit card, Western Union or cryptocurrency options. Installment options are not currently available for credit cards other than Turkish banks.

    Shipping

    Standard Shipping Conditions

    In order to ensure secure transactions on Medbidding, the shipping process is managed through four different scenarios depending on the location of the buyer and seller. Free shipping is available for some categories. The terms below apply to all categories unless otherwise stated.

    Buyer and Seller in Turkiye

    • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
    • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

    Buyer Outside of Turkiye, Seller in Turkiye

    • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
    • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

    Buyer in Turkiye, Seller Outside Turkiye

    • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
    • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

    Buyer and Seller Outside Turkiye

    • Technical Inspection: Technical inspections are performed by our business partner in the seller's country (where available) or by our engineers via remote video call.
    • Seller → Buyer: The seller packages the product and sends it to the buyer's address. The seller is responsible for this shipping cost.

    Objective AI Report

    Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.

    Report date: 14.10.2025

    GE LOGIQ 180 Ultrasound Device Analysis Report

    Overview and Product Description

    The device shown in the visuals is a wheeled ultrasonography system used for medical diagnosis. The GE logo and the LOGIQ 180 model inscription are clearly legible on the device. Based on this information, the product’s brand and model have been confirmed as GE LOGIQ 180. The product is a medical equipment used for imaging organs and tissues in the human body. The visuals show one main unit, a monitor integrated into this unit, a control panel, a wheeled stand, and at least one ultrasound probe (transducer).

    Physical Condition and Deformation

    The general condition of the device is assessed as used. A noticeable color change from its original white to yellowish is observed in the plastic casing. This may indicate the age of the device or prolonged exposure to specific light conditions. Dirt and dust accumulations are present on the device’s body, wheeled stand, and wheels. No significant crack, break, or dent has been detected on the device’s screen or casing.

    Mechanical and Electronic Components

    The mechanical and electronic components of the device generally appear functional.

    • Mechanical Components: The device’s wheels appear physically intact, but they have accumulated significant dirt and show signs of wear. The buttons and the trackball on the control panel are in place, and no significant damage is observed. Probe holders and other plastic parts are complete.
    • Electronic Components: The device is understood to be operational as its screen is on. An ultrasound image and various technical parameters are displayed on the screen. This indicates that the device’s primary electronic circuits and screen are functional.
    • Screen Analysis: The monitor is operational and displays a standard ultrasound menu interface. Information such as date and time is visible in the upper left part of the image but cannot be read clearly. The screen indicates that the device’s imaging capability is active.

    Accessories and Connection Ports

    Accessories and connection points supplied with the device have been examined in the visuals.

    • Ultrasound Probe: One ultrasound probe is located in the probe holder on the right side. The type or model of the probe cannot be determined from the visual.
    • Connection Ports: There are two probe connection sockets (ports) on the front panel of the device. This indicates that two different probes can be connected to the device simultaneously.
    • Cables: Power and probe cables connected to the device are present. No severe crushing or peeling has been observed on the outer surface of the cables.

    Label Information

    There is a label on the back of the device, but its content cannot be read clearly. Only a sticker containing the phrase “KUTAY TIBBİ CİHAZLAR” (KUTAY MEDICAL DEVICES) is visible; this is likely a label indicating the device’s technical service or seller. Information such as serial number, REF code, lot number, or year of manufacture could not be obtained from the visuals.

    Potential Risk Assessment

    The device being in working condition is a positive indicator. However, the noticeable yellowing of the plastic casing suggests that the device might be an older model or has been subjected to intensive use. The dirt on the wheels and the overall casing suggests that detailed maintenance and cleaning could be beneficial. No broken part or obvious sign of malfunction directly affecting the device’s functionality has been detected in the visuals. The current condition of the device is at a reasonable level for used medical equipment.