Ready For Sale

Whatsapp »
SKU: MBC8LL97OFL

Secondhand GE Logiq 200 Ultrasound Machine

Price: USD$ 1.300,00 Approx: 55.900,00 TL

, , , ,

Ready For Sale

Don't Want To Buy At This Price?

    Bid


    * We kindly ask you to write your Whatsapp number with the country code so that we can contact you quickly.

    Click once and wait.

    Ask a Question

      Fill in the form below to send us your message. Click the button and wait. We will contact you as soon as possible.


      * We kindly ask you to write your Whatsapp number with the country code so that we can contact you quickly.

      Click once and wait.

      Payment

      No additional fees, full assurance. We provide complete financial and operational security in secondhand medical device trading. For this, we offer the "Secure Payment" service. This free service protects the rights of both parties by securing the buyer's money and the seller's product. The Secure Payment system is a standard assurance mechanism offered by Medbidding. For additional information, review the "services" page.

      There is no cash on delivery order system on the Medbidding platform. For payments to be made by credit card, the product to be purchased must comply with this payment method. You can contact us to get information about this. We would be happy to assist you.

      For payments made outside of Turkiye, you can choose bank transfer, credit card, Western Union or cryptocurrency options. Installment options are not currently available for credit cards other than Turkish banks.

      Shipping

      Standard Shipping Conditions

      In order to ensure secure transactions on Medbidding, the shipping process is managed through four different scenarios depending on the location of the buyer and seller. Free shipping is available for some categories. The terms below apply to all categories unless otherwise stated.

      Buyer and Seller in Turkiye

      • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
      • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

      Buyer Outside of Turkiye, Seller in Turkiye

      • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
      • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

      Buyer in Turkiye, Seller Outside Turkiye

      • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
      • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

      Buyer and Seller Outside Turkiye

      • Technical Inspection: Technical inspections are performed by our business partner in the seller's country (where available) or by our engineers via remote video call.
      • Seller → Buyer: The seller packages the product and sends it to the buyer's address. The seller is responsible for this shipping cost.

      Objective AI Report

      Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.

      Report date: 20.10.2025

      GE LOGIQ 100 PRO Ultrasound Device Analysis Report

      Overview and Product Description

      The images show an ultrasound device positioned on a wheeled stand, used for medical imaging, and its associated probes. The product consists of a main unit, a screen connected to this unit, an integrated control panel, and various imaging probes. The general structure of the device indicates its suitability for diagnostic use in clinical settings or hospitals. The accompanying probes suggest that the product is used in areas such as gynecology, obstetrics, and general abdominal imaging.

      Brand and Model Information

      As a result of detailed visual analysis and inspections, the brand and model information of the device and its accessories have been definitively identified.

      • Ultrasound Device Brand-Model: Thanks to the “LOGIQ 100 PRO” inscription on the main unit’s screen frame and the “GE Medical Systems” phrase found on the probe labels, the device’s brand has been identified as GE and its model as LOGIQ 100 PRO.
      • Ultrasound Probes Brand-Model:
        • One GE 3.5C Convex Probe.
        • One GE E8C Endocavity (Transvaginal) Probe.
        • One more probe is present, whose brand and model cannot be read from the label, and which appears to be a Linear Probe based on its physical structure.

      The logos, labels, and overall build quality on the product indicate that it is an original GE product.

      Physical Condition and Deformation Analysis

      It is clearly understood that the device is used. Its general condition shows wear and tear commensurate with its age. Its physical condition can be summarized as follows:

      • Color Change: There is a noticeable yellowing and color fading in the plastic parts of the device, especially around the control panel and keyboard. This condition may indicate long-term use or exposure to sunlight.
      • Surface Condition: No significant cracks, fractures, or dents are observed on the device’s general casing. However, there is general dirt and dust on its surface. It could achieve a better appearance with a detailed cleaning.
      • Mechanical Parts: Mechanical parts of the device such as the wheels, monitor support arm, and probe holders are visually intact and in place.
      • Screen: The device’s screen is off, therefore it cannot be determined whether it is functional or if there are any scratches on it.

      Accessories and Equipment

      A total of 3 ultrasound probes are present with the device in the images. These probes are seen as a whole with their cables. The device’s power cable is also present. Apart from these, a user manual, gel, or other accessories are not shown in the images.

      Label and Code Information

      The following information has been obtained from the labels on the probes:

      • GE E8C Endocavity Probe:
        • Model: E8C
        • REF Code: 2261234-2
        • Serial Number: 22754WX0
      • GE 3.5C Convex Probe:
        • Model: 3.5C
        • REF Code: 2260193-2
        • Serial Number: 21634WX1

      Potential Risk Assessment

      No visible broken or faulty parts are found on the device. However, the extensive yellowing of the plastic components, indicating the product’s age, suggests that the electronic components might also be old. For such medical devices, it is recommended that their functions be fully verified by an expert technician and that calibration be performed. Although the visual condition of the probes and their cables appears good, their image quality and functionality can only be tested by operating the device.