Ready For Sale
Secondhand Mindray DP-8800 Plus Ultrasound Machine
Price: USD$ 1.000,00 Approx: 45.000,00 TL
Ready For Sale
Ask a Question
Payment
No additional fees, full assurance. We provide complete financial and operational security in secondhand medical device trading. For this, we offer the "Secure Payment" service. This free service protects the rights of both parties by securing the buyer's money and the seller's product. The Secure Payment system is a standard assurance mechanism offered by Medbidding. For additional information, review the "services" page.
There is no cash on delivery order system on the Medbidding platform. For payments to be made by credit card, the product to be purchased must comply with this payment method. You can contact us to get information about this. We would be happy to assist you.
For payments made outside of Turkiye, you can choose bank transfer, credit card, Western Union or cryptocurrency options. Installment options are not currently available for credit cards other than Turkish banks.
Shipping
Standard Shipping Conditions
In order to ensure secure transactions on Medbidding, the shipping process is managed through four different scenarios depending on the location of the buyer and seller. Free shipping is available for some categories. The terms below apply to all categories unless otherwise stated.
Buyer and Seller in Turkiye
- Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
- Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.
Buyer Outside Turkiye, Seller in Turkiye
- Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
- Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.
Buyer in Turkiye, Seller Outside Turkiye
- Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
- Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.
Buyer and Seller Outside Turkiye
If there is a local operation center in the seller's country:
- Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
- Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.
If there is no operation center in the seller's country:
- Technical Inspection: Inspections are performed by our engineers via remote video call.
- Seller → Buyer: The seller packages the product and sends it directly to the buyer's address. The seller is responsible for this shipping cost.
Objective AI Report
Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.
Report date: 02.02.2026
Mindray Digi Prince DP-8800 Plus Ultrasound Device Analysis Report
Device Identification
The images show a medical ultrasound imaging system integrated onto a mobile stand. The system primarily consists of a CRT monitor, a control panel with a keyboard, a main processing unit (lower chassis), a trolley stand, and one imaging probe.
Brand and Model
Based on the text located in the upper left part of the product’s monitor frame, the brand and model information has been identified as Mindray Digi Prince DP-8800 Plus. The Mindray logo is located in the lower central part of the monitor. The Sony brand is visible on the disk drive seen on the side panel.
Originality
Upon examining the device’s external casing, logo placements, control panel layout, and the structure of the materials used, the product is assessed to be an original Mindray production. No visual evidence of an aftermarket or copy production has been found.
Areas of Use
This device is a digital ultrasound system used for medical imaging and diagnosis. It is designed to be used in specialties such as radiology, obstetrics (Obstetrics/Gynecology), urology, and general abdominal examinations for imaging internal organs, soft tissues, and the fetus.
Quantity Information
The images show 1 main ultrasound device unit (including stand and monitor) and 1 ultrasound probe connected to the device.
General Condition
The device generally maintains its integrity, but there are clear visual signs of aging. The product is a used device. The feet of the device have been wrapped with stretch film for protection during transport or storage.
Physical Deformations
A noticeable yellowing (discoloration) is observed on the plastic casing of the device, especially on the rear and side covers of the monitor (CRT case part), caused by time and UV light exposure. While the lower part of the main body and the control panel retain more grey/white tones, the color of the monitor casing has significantly darkened. No deep cracks, breaks, or dents have been detected in the images.
Mechanical Components
The buttons, slide potentiometers (TGC keys), and trackball (cursor ball) on the control panel appear physically in place and intact. The probe holders are sturdy. Although the surface condition of the wheels cannot be clearly seen as the wheeled feet are wrapped with stretch film, the stand appears to be stable.
Electronic Components
There is no screen image (software interface) indicating that the device is operational; the screen is off. However, in the second image, a red “mindray” reflection or a similar image resembling a screen protector trace is discernible on the monitor; it cannot be definitively distinguished from the images whether this originates from the device being on or from an environmental reflection. The green button and LED slot of the disk drive located on the side are physically in place.
Accessories
One wired probe is present on the device. The probe connector is plugged into the lower port of the device. Additionally, a Sony branded data storage drive (likely a Floppy or MO drive) is located on the side panel.
Battery Status
The device is a stand-mounted model powered by mains electricity (220V/110V). No external battery unit or indicator/label related to battery status is found in the images.
Label Information
Label and text information obtained from the images is as follows:
- Monitor Top: Digi Prince DP-8800 Plus
- Monitor Logo: Mindray emblem
- Probe Label: 35C50EA (This code refers to the probe’s model or technical reference)
- Side Drive: Sony
- Warning Labels: General warning signs within a yellow triangle are present on the control panel.
Screen Analysis
The monitor is of the CRT (cathode ray tube) type, which is an older generation display technology. This provides information about the device’s technological generation. Apart from slight wiping marks and reflections on the screen’s matte surface, no deep scratches or cracks are visible.
Dimensions and Compatibility
The device is a standard hospital/clinic type mobile unit designed for adult use. Based on the probe’s code (35C50EA), it can be stated that this part has a convex structure and is suitable for abdominal examinations.
Documentation
No invoice, warranty certificate, user manual, or service report belonging to the device is found in the images.
Potential Failure Risk
The product visually shows age-related cosmetic wear (plastic yellowing). In such devices with CRT monitors, it is common for the display tube to lose brightness or for image clarity to decrease over time. Additionally, frequently used parts like the mechanical trackball and keypad may experience loss of sensitivity due to long-term use. However, no physical damage (cracks, broken cables, shattered screen, etc.) that would prevent the device from operating has been detected in the images.