Ready For Sale

Whatsapp »
SKU: MBHG3UJM725

Secondhand Shimadzu Shimasonic SDL-10 Ultrasound Machine

, , , ,

Price: USD$ 500,00 Approx: 22.500,00 TL

Ready For Sale

Objective AI Report

Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.

Report date: 17.11.2025

Shimadzu Shimasonic SDL-10 Ultrasound Device Analysis Report

Overview and Device Description

The images show a diagnostic ultrasonography (ultrasound) device, model Shimasonic SDL-10, by the Shimadzu brand. The device is a complete system used for medical imaging, consisting of components such as a monitor, control panel, main unit, and external probe (transducer). The general appearance of the product indicates retro technology and suggests it is an older model. The system has a multi-layered structure that appears to be mounted on a wheeled stand.

Brand and Model Information

The brand and model of the product are clearly readable on both the front panel of the device and on the metal information label on its back. This information is detailed below:

  • Brand: Shimadzu Corporation
  • Model: Shimasonic SDL-10

This information is 100% accurate based on visual evidence and leaves no doubt regarding the product’s originality. The labels and logos are professional and consistent with their period.

Condition Assessment

The device is in a used condition, showing its age. There is visible yellowing on its casing and plastic components. This yellowing indicates that the product has been in use for a long time or is an older technology. The overall condition of the device can be evaluated as “used”. While there is no information regarding its operational status, no signs of burning or serious damage are visible.

Physical and Mechanical Deformation

The physical condition of the device is detailed below:

  • Casing: The casing of the main unit and monitor is made of cream-colored plastic and has significantly yellowed over time. Small scratches and dirt are visible on the casing, but no major cracks, breaks, or dents have been detected.
  • Control Panel: The “POWER” button and adjustment knobs like “CALIPER”, “GAIN”, and “NEAR GAIN” located on the front panel are physically in place.
  • Monitor: The hinges of the cover compartment in front of the monitor appear sturdy. Since the screen is off, it is not possible to clearly determine if there are scratches on its surface.
  • Transducer (Probe): The one transducer connected to the device is physically the most worn part. The olive-green colored grip material on the handheld portion of the probe shows numerous cracks and flaking. This indicates that the probe has been heavily used and its material is nearing the end of its lifespan.
  • Cables and Connectors: There are numerous cable connections at the back of the device. No significant crushing, cuts, or breaks are observed in the outer insulation of the cables. The connectors are metal and are plugged into their respective places.

Technical Specifications and Label Information

The metal label on the back of the device contains important technical information and identification codes. This information includes:

  • Product Name: DIAGNOSTIC ULTRASOUND EQUIPMENT
  • Model: SDL-10
  • Serial Number (NO.): 684572 43
  • Power Requirement (LINE): 220V 50/60Hz
  • Class (CLASS): 1-B
  • Manufacturer: SHIMADZU CORPORATION, Kyoto, Japan

Additionally, the small label on the transducer connected to the device contains the following information:

  • Part Name: TRANSDUCER
  • Frequency: 3.5 MHz

Accessories and Connection Points

The device and its accessories identified in the images are as follows:

  • Quantity: 1 Shimasonic SDL-10 main unit and monitor, at least 1 transducer (probe), and power and data cables connected to the device.
  • Transducer: One probe operating at 3.5 MHz and its connected cable are clearly visible in the image. The probe has a storage compartment or slot.
  • Connection Points: The rear panel of the device features numerous circular, multi-pin connector inputs. At least three large black connectors are seen plugged in the images. Additionally, there are extra screw terminals for grounding or various signals.

No other accessories, such as an external box or user manual, are present in the images.

Screen Analysis

The monitor screen of the device is turned off in all images. Therefore, it is not possible to analyze whether there is any image, text, menu, or error message on the screen. No comment can be made regarding whether the screen is functional or its image quality.

Potential Malfunction Risks

The general age of the device is the most significant potential malfunction risk. Especially the extensive cracks and flaking observed in the material of the handheld portion of the transducer probe suggest that this part is nearing the end of its service life. This condition could lead to hygiene and safety issues during use, as well as carry the risk of the part becoming completely non-functional. Although there is a possibility of performance issues in the future due to the age of the electronic components, there is no direct evidence of an existing electronic fault in the images.