Ready For Sale

Whatsapp »
SKU: MBMQDK186HB

Secondhand GE L6-12-RS 5459829 Linear Ultrasound Probe

, , , , ,

Medbidding Engineers Verify

Secure Payment System

Price: USD$ 1.400,00 Approx: 63.000,00 TL
Bid

Ready For Sale

Objective AI Report

Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.

Report date: 08.06.2026
Report code: 1780929658

GE L6-12-RS Ultrasound Probe Analysis Report

Device Identification

The images show an ultrasound probe used in the field of medical imaging and its connected cable. The device is a transducer that uses ultrasound waves to image the internal organs and tissues of patients.

Brand and Model Information

Upon examining the logo and label information on the product, it is clearly understood that the brand of the device is GE. The model information is specified as “L6-12-RS”.

Authenticity Assessment

Details such as the GE logo on the product in the image, the print quality of the labels, technical information, and the CE mark suggest that the device is an original product. The quality of workmanship and general appearance indicate that it complies with standard manufacturing processes.

Usage Areas

The GE L6-12-RS linear ultrasound probe is used in various medical applications due to its wide bandwidth and high-frequency range. This probe is particularly suitable for imaging superficial structures and small organs. Its primary usage areas are as follows:

  • Vascular Imaging: Examination of blood vessels (carotid, lower and upper extremity arteries and veins).
  • Musculoskeletal (MSK): Evaluation of tendons, ligaments, joints, and muscles.
  • Small Parts: Imaging of the thyroid, breast, and other superficial tissues.
  • Abdominal Imaging: Can also be used for certain abdominal applications.
  • Pediatrics: Examination of superficial structures in pediatric patients.

This probe works with compatible GE HealthCare ultrasound systems such as GE Versana, LOGIQ P-series, LOGIQ V2, LOGIQ P6, LOGIQ P7, and Vivid T8, Vivid T9.

Quantity Information

One ultrasound probe is visible in the images. No other accessories or products are present.

General Condition

The general condition of the device appears to be good. No significant wear or heavy signs of use have been detected on the surface of the product. The label information is clear and legible.

Physical Deformation

There are no visible scratches, dents, cracks, or discoloration on the housing, probe head, or cable connection point of the product. The surface appears clean and well-maintained.

Mechanical Components

No visible issues have been detected in the mechanical components, including the probe head, cable connection point, and connector part. All parts are intact and in place.

Electronic Components

The electronic pins in the connector part of the device appear clean and properly aligned. There are no signs of bending, breakage, or corrosion on the pins.

Accessories

Other than the ultrasound probe itself, no boxes, additional cables, or other accessories are visible in the images. There is a multi-pin socket input on the device. This socket allows the probe to be connected to the ultrasound system.

Battery Status

The product in the image is an ultrasound probe and does not have an internal or external battery. It receives power from the ultrasound system to which it is connected.

Label Information

The label on the product contains the following information:

  • Brand and Model: GE L6-12-RS
  • REF Code: 5459829
  • Serial Number (SN): 981815WX4
  • Place of Manufacture: Assembled in China
  • Manufacturer: GE Medical Systems (China) Co., Ltd. No. 19, Changjiang Road Wuxi National Hi-Tech Dev. Zone 214028 Jiangsu China
  • Manufacturing Date: 2021-04 (April 2021)
  • UDI (Unique Device Identifier): (01)00840682104975(11)210400(21)981815WX4
  • IPX Code: IPX7
  • CE Mark: European Union conformity mark
  • WEEE Symbol: Symbol indicating that waste electrical and electronic equipment must be collected separately
  • MD Symbol: Symbol indicating that it is a medical device
  • Other Code: 5448214-06

This information demonstrates the product’s identity, traceability, manufacturing details, and compliance with international standards. The REF code indicates the catalog number of the product; the serial number is the identifier that makes each device unique; the UDI is the code that enables global device tracking; and IPX7 indicates the device’s level of protection against water (protected against immersion in water under specific conditions).

Screen Analysis

Since the product in the image is an ultrasound probe, it does not have a screen. Therefore, a screen analysis could not be performed.

Dimensions and Compatibility

There is no direct information regarding the specific measurements or size of the product in the images. However, due to its linear probe structure, it is designed for imaging superficial structures. According to the information on the label, the probe head width has an aperture of 38.4 mm. This offers a compact footprint to cover structures such as thyroid lobes and vascular segments. It is stated that the device is compatible with GE Versana, LOGIQ, and Vivid T9 series ultrasound systems.

Year of Manufacture

The expression “2021-04” is clearly visible on the label of the product. This information indicates that the device was manufactured in April 2021.

Documents

No invoices, warranty certificates, user manuals, or other documents belonging to the device are visible in the images.

Usage Duration

There is no data regarding usage hours or total usage duration on the device or in the label information.

Existing Faults

No evidence of any obvious faults such as broken parts, severed cables, missing components, or error messages has been detected anywhere on the device in the images. The product appears intact and sound.

Potential Fault Risk

The general condition of the device is good. No concrete situation that could pose a potential fault risk, such as severe wear, rusting, or cable crushing, has been observed in the images.