Secondhand Sedecal 500mA Fixed X-Ray Device

, , , ,

Price: USD$ 13.000,00 Approx: 585.000,00 TL

Sold Out

Objective AI Report

Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.

Report date: 05.08.2025

X-ray Device Analysis Report

Overview and Device Identification

The images show a fixed X-ray device system used for medical diagnostic purposes. This system consists of an X-ray table, a chest stand (bucky stand), and a floor-to-wall mounted X-ray tube column. The brand and model of the device could not be identified from the images. Based on the general workmanship, material structure, and design details, it is understood to be an original medical device from a professional manufacturer.

The device is designed for performing various radiographic examinations in hospitals, clinics, and imaging centers.

Quantity Information

The breakdown of the product and accessories shown in the images is listed below:

  • 1 X-ray Table
  • 1 Chest Stand
  • 1 X-ray Tube and Column
  • 1 Two-Step Patient Stool
  • 1 Lead Protective Apron

General Condition and Physical Deformation

The overall condition of the device is assessed as used. No significant scratches, dents, cracks, or color fading were observed on the surfaces of the white and turquoise system. It has a generally clean appearance and appears to be well-maintained in its current environment. There is no significant layer of dirt or dust on the parts. Slight wear can be seen on the edges of the two-step patient stool, which is consistent with normal use.

Mechanical and Electronic Components

The mechanical parts of the device, such as the floor rails, column, and moving arms, are in visually good condition. There is no visible rust, bending, or breakage on these parts. The mechanisms that provide mobility for the arm carrying the X-ray tube and the chest stand appear structurally sound. No crushing, cuts, or wear were detected in the insulation of the cables that make up the device’s electronic components. Although the wall-mounted control panel or generator unit is visible in the image, it cannot be determined whether it is in working condition.

Accessories and Complementary Equipment

Along with the system, there is a two-step stool to facilitate patient access and a blue lead apron hanging on the wall. Next to the X-ray table, a long, metal-framed part is seen on the floor, which is thought to belong to the system but is not installed. The exact function of this part and why it is detached cannot be determined from the image. No cable or socket inputs are clearly visible on the device.

Labels and Technical Information

The labels on the device are not legible due to the resolution of the images. Therefore, the following information could not be obtained:

  • Serial Number
  • Lot Number
  • REF Code
  • Year of Manufacture

Only the standard yellow radiation warning sign is present on the X-ray tube.

Potential Risk Assessment

The device gives the impression of being in good condition based on its overall state. No conditions that could pose an immediate risk of failure, such as severe wear, rust, or damage to cables, have been observed. However, the disassembled part on the floor is a significant point. The fact that this part belongs to the system and is not installed suggests that the system may be incomplete or partially dismantled. This situation could impede the device’s operation and requires inspection by a technician before installation or use. Apart from this detail, there are no alarming risk factors in the physical structure of the device.