Sold Out

Whatsapp »
SKU: MBGXBCZUD68

Secondhand Konica SRX-101A Automatic X-Ray Film Bath Device

,

Price: USD$ 751,00 Approx: 33.795,00 TL

Sold Out

Don't Want To Buy At This Price?

Sorry. This product has been sold. You cannot bid. Please check out other products.

Ask a Question

    Fill in the form below to send us your message. Click the button and wait. We will contact you as soon as possible.


    * We kindly ask you to write your Whatsapp number with the country code so that we can contact you quickly.

    Click once and wait.

    Payment

    No additional fees, full assurance. We provide complete financial and operational security in secondhand medical device trading. For this, we offer the "Secure Payment" service. This free service protects the rights of both parties by securing the buyer's money and the seller's product. The Secure Payment system is a standard assurance mechanism offered by Medbidding. For additional information, review the "services" page.

    There is no cash on delivery order system on the Medbidding platform. For payments to be made by credit card, the product to be purchased must comply with this payment method. You can contact us to get information about this. We would be happy to assist you.

    For payments made outside of Turkiye, you can choose bank transfer, credit card, Western Union or cryptocurrency options. Installment options are not currently available for credit cards other than Turkish banks.

    Shipping

    Standard Shipping Conditions

    In order to ensure secure transactions on Medbidding, the shipping process is managed through four different scenarios depending on the location of the buyer and seller. Free shipping is available for some categories. The terms below apply to all categories unless otherwise stated.

    Buyer and Seller in Turkiye

    • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
    • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

    Buyer Outside Turkiye, Seller in Turkiye

    • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
    • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

    Buyer in Turkiye, Seller Outside Turkiye

    • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
    • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

    Buyer and Seller Outside Turkiye

    If there is a local operation center in the seller's country:

    • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
    • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

    If there is no operation center in the seller's country:

    • Technical Inspection: Inspections are performed by our engineers via remote video call.
    • Seller → Buyer: The seller packages the product and sends it directly to the buyer's address. The seller is responsible for this shipping cost.

    Objective AI Report

    Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.

    Report date: 12.02.2026

    Konica Minolta SRX-101A Film Processor Analysis Report

    Device Identification and Description

    The device in the examined images is a desktop-type automatic X-ray film processor used in the field of medical imaging. The device is placed on a specially manufactured metal stand with fixed, non-wheeled legs. The main unit is an industrial medical equipment featuring mechanical roller systems and chemical tank reservoirs for developing films in a darkroom.

    Brand and Model Information

    Upon examining the model label located at the front upper left corner of the device, it was clearly identified that the product’s model is SRX-101A. This model code indicates compact film processors manufactured by the Konica Minolta brand, adhering to industrial standards. The product’s typical beige casing, blue circular logo detail, and the SRX-101A model designation confirm this identification.

    Originality Status

    The casing structure, labeling points, color codes, and mechanical internal component arrangement (rollers and gears) of the device shown in the images match the manufacturer’s standard factory specifications. No visual evidence of aftermarket modification or incompatible part addition was found; the product appears original.

    Areas of Use

    This device is used in healthcare institutions where conventional (non-digital) X-ray systems are utilized; in hospital radiology departments, medical centers, and veterinary clinics for the chemical processing of X-ray films (developing, fixing, washing, and drying). The product is a standalone unit.

    General Condition and State

    The general condition of the device is “used” and “requiring maintenance”. It is observed that the product has a history of intensive use and has likely been stored idly in a warehouse environment for some time. Yellowing and dirt accumulation are present on the device’s casing in various places. It is not in “zero” or “new” condition.

    Physical Deformation Examination

    • Outer Casing: The device’s beige plastic casing is intact; however, it is visually dirty. No significant breaks or cracks were visually detected on the front cover and upper feed tray areas.
    • Metal Stand: The paint on the metal stand supporting the device shows abrasions and color changes that may indicate rust in various places. The stand retains its structural integrity but is cosmetically worn.

    Mechanical Component Analysis

    In the images, particularly in the details where the device’s top cover is open and the internal mechanism is visible, the following points have been identified:

    • Roller System: Black rubber rollers (cylinders) forming the device’s film transport system are present. Dust and residue accumulation are observed on the rollers. Although the condition of the rubber material cannot be fully assessed from the image, there is a risk of hardening or deformation in these rollers in devices that have been idle for a long time.
    • Gear Assembly: White plastic gears that drive the rollers are clearly visible on the right side. No missing or broken teeth were detected on the visible gears, but dirt is present between the gear teeth.
    • Motor and Motion Transmission: Since the motor block is beneath an enclosed area in the images, no comment can be made regarding the physical condition of the motor.

    Accessories and Parts

    Based on the analysis of the images, the identified components and quantity information are as follows:

    • Main Unit: 1 Unit of SRX-101A Film Processor.
    • Support Stand: 1 Unit of metal stand with six shelves, perfectly compatible with the device.
    • Hoses: At least one transparent/yellowed drainage hose is hanging from the bottom of the device. The hose color appears to have yellowed over time.

    Label and Warning Information

    The model designation “SRX-101A” is present on the front face of the device. In the internal feed tray area, there are yellow and black industrial warning labels indicating how the user should place the film or highlighting hazardous areas (e.g., pinch points). These labels are partially faded but retain their presence.

    Battery and Power Supply

    This device is an industrial unit operating on mains electricity (220V/110V). No internal or external battery system is visible in the images, and due to the nature of the device, it does not operate on batteries. The end of the power cable is visible on the ground, but the plug head cannot be clearly distinguished.

    Existing Faults and Potential Risks

    No definitive evidence of a fault, such as “error code,” “broken screen,” or “detached part,” is present in the images. However, potential risks based on visual inspection include:

    • Chemical Residue Risk: Since these types of devices operate with chemical solutions, there is a high probability of chemical crystallization and blockages forming in the internal reservoirs and hoses if unused for prolonged periods. The color of the drainage hose bears traces of this usage.
    • Rubber Roller Lifespan: It is probable that the black rubber rollers in the internal mechanism will lose their elasticity over time; this could lead to film jamming.
    • Need for Cleaning: The internal and external components of the device require thorough cleaning and likely professional maintenance.

    Documents and Warranty

    No user manual, invoice, or warranty document for the product is present in the images. Considering the age and condition of the device, it is deemed to be out of warranty coverage.