Objective AI Report
Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.
Report date: 01.07.2026
Report code: 1782910541
TOSHIBA Aplio 500 Ultrasound Device Analysis Report
Device Identification and Brand Model Information
The product examined in the images is an ultrasound system. The brand of the device is clearly identified as TOSHIBA, and the model as Aplio 500. This information is clearly legible both on the upper part of the monitor and on the front panel of the main unit.
Authenticity Assessment
Considering the logo quality, label placement, and general workmanship details in the images, the impression is that the product is original. No signs of counterfeiting have been observed.
Usage Areas
The TOSHIBA Aplio 500 is a high-performance ultrasound device. This system is used for diagnostic imaging in many medical branches such as radiology, cardiology, obstetrics and gynecology, urology, general surgery, and vascular medicine. It specifically allows for detailed examination of various organs and tissues, including the breast, abdomen, thyroid, musculoskeletal system, and vascular structures.
Quantity Information
- The main device subject to this report is one ultrasound system.
- There are two ultrasound probes attached to the device.
General Condition and Physical Deformation
The general condition of the device appears to be good and well-maintained. No physical deformations such as significant scratches, dents, cracks, or discoloration have been observed on the casing, monitor, or control panel. The surfaces of the device are clean, and there is no accumulation of dirt or dust.
Mechanical and Electronic Components
Mechanical components such as buttons, rotary knobs, and the trackball on the control panel appear to be intact. The probe holders and wheels also show no signs of damage. Internal components regarding the electronic assembly of the device are not visible in the images. However, the fact that the screen is on and functional suggests that basic electronic functionality is present.
Accessories and Socket Inputs
Two ultrasound probes are visible with the device. The cables of the probes are neatly connected to the device. There are multiple probe socket inputs on the side of the device. These inputs are occupied and actively in use. There are no signs of damage or wear on the socket inputs.
Battery Status
There is no external battery pack visible in the images. Although a battery icon appears on the device screen, no visual information regarding the charge level or physical condition of the battery could be obtained. No comments can be made regarding the status of the internal battery.
Label Information
Specific label information such as serial number, lot number, or REF code is not clearly legible in the images. Therefore, no detailed explanation can be provided regarding this information.
Screen Analysis
The main monitor of the device is on, and various information is displayed on it. The information TOSHIBA Aplio 500, 300606 AHSEN BAKAN, and BAKIRKOY REIMLI ULTRASON is located at the top of the screen. Additionally, it shows that a Breast examination is being performed, the user ABAKAN is active, and the date/time is displayed as 30.06.2026 11:51:09. Technical parameters such as AP:100% (Acoustic Power), MI:1.5 (Mechanical Index), TIS:0.4 (Thermal Index Soft Tissue), DFI:10, 24 fps (Frame Rate), DR:70, and P:7 are listed in the upper right corner of the screen. Depth markers such as 0.1, 0.2, 0.3, and 0.4 are present on the left side. On the small screen below the control panel, mode selections such as Preset, Exam, and Doppler, along with imaging settings like B-Mode, M-Mode, Color, Power, PW, CW, ADF, THI, A.Pure, DFI, 2D, DR, P, and probe types such as Linear, Convex, and Sector are displayed. This information indicates that the device offers various imaging modes and settings to the user.
Dimensions and Compatibility
The images do not contain specific dimensions or physical compatibility information for the device. However, the fact that the device is on a wheeled stand indicates that it is designed for mobile use and can be easily moved within a standard hospital or clinical environment.
Year of Manufacture
There is no direct year of manufacture label on the device. However, the date 30.06.2026 visible on the screen suggests that the device was actively in use on this date and has up-to-date software. The general design and modern interface of the device indicate that it is a model produced in the recent past.
Documents
No documents such as invoices, warranty certificates, or user manuals belonging to the device were encountered in the images.
Usage Duration
There is no information regarding the total usage hours or duration on the device screen or labels.
Existing Faults
No existing faults such as broken parts, error messages, or severed cables that would prevent the device from operating were detected in the images. The device screen appears to be on and functional.
Potential Risk of Failure
The general condition of the device is good. No concrete situations that could pose a potential risk of failure, such as severe wear, rust, or cable crushing, were observed in the images.