Ready For Sale
Secondhand Neuro-MSX TMS Device
Price: USD$ 17.000,00 Approx: 765.000,00 TL
Ready For Sale
Ask a Question
Payment
No additional fees, full assurance. We provide complete financial and operational security in secondhand medical device trading. For this, we offer the "Secure Payment" service. This free service protects the rights of both parties by securing the buyer's money and the seller's product. The Secure Payment system is a standard assurance mechanism offered by Medbidding. For additional information, review the "services" page.
There is no cash on delivery order system on the Medbidding platform. For payments to be made by credit card, the product to be purchased must comply with this payment method. You can contact us to get information about this. We would be happy to assist you.
For payments made outside of Turkiye, you can choose bank transfer, credit card, Western Union or cryptocurrency options. Installment options are not currently available for credit cards other than Turkish banks.
Shipping
Standard Shipping Conditions
In order to ensure secure transactions on Medbidding, the shipping process is managed through four different scenarios depending on the location of the buyer and seller. Free shipping is available for some categories. The terms below apply to all categories unless otherwise stated.
Buyer and Seller in Turkiye
- Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
- Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.
Buyer Outside Turkiye, Seller in Turkiye
- Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
- Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.
Buyer in Turkiye, Seller Outside Turkiye
- Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
- Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.
Buyer and Seller Outside Turkiye
If there is a local operation center in the seller's country:
- Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
- Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.
If there is no operation center in the seller's country:
- Technical Inspection: Inspections are performed by our engineers via remote video call.
- Seller → Buyer: The seller packages the product and sends it directly to the buyer's address. The seller is responsible for this shipping cost.
Objective AI Report
Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.
Report date: 16.02.2026
Neurosoft Neuro-MSX Magnetic Stimulator Device Analysis Report
Device Identification
The product shown in the image is a Transcranial Magnetic Stimulation (TMS) system mounted on a wheeled medical transport stand, used in neurological and psychiatric applications. The system has an integrated structure consisting of a main control unit, a cooling unit, a magnetic coil, and a coil holder arm mechanism.
Brand and Model
On the front panel of the main control unit located on the middle shelf of the device, the phrase “Magnetic St…” (a partial view of the words Magnetic Stimulator) is clearly visible on the top left side of the screen, and the inscription Neuro-MSX along with the brand-specific logo is clearly legible on the top right side. In light of these visual evidences and logo design, the device’s identity is as follows:
- Brand: Neurosoft
- Model: Neuro-MSX
When confirmed with internet data, the Neuro-MSX model of the Neurosoft brand is a magnetic stimulator device used for diagnostic and therapeutic purposes.
Applications
Neurosoft Neuro-MSX is a medical device that generates a magnetic field to stimulate the brain’s cortex or the peripheral nervous system. Its primary applications include:
- Diagnostic Purposes: Measurement of Motor Evoked Potentials (MEP) and analysis of conduction pathways.
- Therapeutic Purposes: Treatment of depression, post-stroke rehabilitation, and treatment of various neurological/psychiatric disorders (rTMS applications).
- Research: Cognitive neuroscience and brain mapping studies.
Quantity Information
When the system is evaluated as a single unit, the following components are observed:
- 1 Main Control Unit (on the middle shelf)
- 1 Cooling/Power Unit (on the bottom shelf)
- 1 Magnetic Stimulation Coil (on the top shelf)
- 1 Transport Cart (Trolley)
- 1 Coil Holder Arm (partially visible on the left side)
- 1 Laptop (in closed position on the top shelf for system control)
General Condition
The device and its components appear to be in good condition and clean visually. It gives the impression of a device used in a hospital or clinic environment but carefully maintained. There is no significant cosmetic wear noticeable.
Physical Deformations and Exterior Casing
Upon detailed examination of the device’s metal casing, the transport cart’s shelves, and the plastic corner protectors:
- No cracks, breaks, or dents have been detected on the front panels, keypads, or screen surface of the main unit and the lower unit.
- The blue corner protector plastics are sturdy, and no significant fading or wear is observed in their color.
- There is no rust or bending on the metal profiles of the transport cart.
Electronic Components and Screen Analysis
A colorful LCD screen is located in the center of the main unit. As the device was turned off or in standby mode during photography, the screen is darkened; therefore, no error codes, menus, or warning messages are displayed on the screen. The large control knob (scroll knob) and physical buttons with ‘Start/Stop’ icons on the front panel are complete and in place. The power button icon on the far right is clearly visible.
Accessories and Coil Structure
On the top shelf of the device, there is a TMS coil connected to the main system with a thick grey cable harness. The coil’s structure is likely a “Figure-of-Eight” coil or a similar focal stimulation coil. The thick hose-like cable structure attached to the coil indicates that this coil has a liquid-cooled system to prevent overheating during high-intensity or repetitive stimulation (rTMS). Additionally, a portion of an articulated mechanical arm, used for comfortable positioning of the coil, is visible on the left side of the image. A silver-colored laptop, in a closed state, used for software control of the system, is located on the top shelf.
Authenticity
Upon examining the brand logos, typographic quality, professional assembly structure of the device, original transport cart (“trolley”), and industrial design details, it is understood that the product is an entirely original Neurosoft production.
Mechanical Components
The wheels of the transport cart ensure its stable stance on the ground, and there is no visible damage to the wheels. The placement of the device units on the shelves is regular. The connection points of the metallic coil holder arm on the left side appear sturdy.
Cables and Connections
The cable connections between the main unit and the lower unit, and to the coil, are orderly. A thick, grey, spiral-protected structure is noticeable on the coil cable; this cable appears shielded and sturdy against external factors. On the left side of the front panel, the coil connection socket is seen to be plugged in; the connection connector is fully seated.
Battery and Power Status
This type of high-energy magnetic stimulator operates with mains electricity (220V). The cables descending from the back of the device indicate a mains connection. No internal battery indicator or battery pack for mobile use is visible in the image, although some models may have integrated uninterruptible power supply; this cannot be confirmed from the image.
Potential Failure Risk
During the visual inspection, no immediate signs of damage were observed in the critical components of the device (screen, coil cable, control knobs). The product’s condition suggests that it does not pose an operational risk. Since there are no bends or crushes in moving parts such as cooling liquid hoses and the coil cable, the risk of short circuits or leaks associated with cables is visually low. The device generally has a clean and safe appearance.