Sold Out

Whatsapp »
SKU: MBR6WZORLYU

Secondhand Oxypure V010-3T Oxygen Analyzer

Price: USD$ 225,00 Approx: 9.900,00 TL

, , , ,

Sold Out

Don't Want To Buy At This Price?

Sorry. This product has been sold. You cannot bid. Please check out other products.

Ask a Question

    Fill in the form below to send us your message. Click the button and wait. We will contact you as soon as possible.


    * We kindly ask you to write your Whatsapp number with the country code so that we can contact you quickly.

    Click once and wait.

    Payment

    No additional fees, full assurance. We provide complete financial and operational security in secondhand medical device trading. For this, we offer the "Secure Payment" service. This free service protects the rights of both parties by securing the buyer's money and the seller's product. The Secure Payment system is a standard assurance mechanism offered by Medbidding. For additional information, review the "services" page.

    There is no cash on delivery order system on the Medbidding platform. For payments to be made by credit card, the product to be purchased must comply with this payment method. You can contact us to get information about this. We would be happy to assist you.

    For payments made outside of Turkiye, you can choose bank transfer, credit card, Western Union or cryptocurrency options. Installment options are not currently available for credit cards other than Turkish banks.

    Shipping

    Standard Shipping Conditions

    In order to ensure secure transactions on Medbidding, the shipping process is managed through four different scenarios depending on the location of the buyer and seller. Free shipping is available for some categories. The terms below apply to all categories unless otherwise stated.

    Buyer and Seller in Turkiye

    • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
    • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

    Buyer Outside of Turkiye, Seller in Turkiye

    • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
    • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

    Buyer in Turkiye, Seller Outside Turkiye

    • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
    • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

    Buyer and Seller Outside Turkiye

    • Technical Inspection: Technical inspections are performed by our business partner in the seller's country (where available) or by our engineers via remote video call.
    • Seller → Buyer: The seller packages the product and sends it to the buyer's address. The seller is responsible for this shipping cost.

    Objective AI Report

    Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.

    Report date: 31.12.2025

    Oxypure V010-3T Oxygen Analyzer Analysis Report

    Device Identification

    The product examined in the visuals is a digital and handheld analyzer designed for medical gas measurement. The device is specifically designed to measure oxygen purity, flow rate, and pressure values. The product is shown with the main unit, metal and plastic inlet ports located on the top, a transparent hose attached to one of these ports, and its original box.

    Brand and Model

    As a result of detailed examinations conducted on the product in the visuals, on its rear label, and on its box, the brand and model information has been definitively identified as follows:

    • Brand: Oxypure (Manufacturer: GEZ Sağlık Ürünleri)
    • Model: V010-3T

    On the box and the label on the back of the device, the full product name is stated as “Oxypure Oxygen Analyzer Three Function”. The label on the back of the device also includes the manufacturer’s company information as “Gez Sağlık Ürünleri San. Tic. Ltd. Şti.” and the phrase “Made in Türkiye”.

    Originality

    The print quality of the labels on the device, the logo placement, the barcoded labels on the box, and the “Quality Control” labels indicate that the product is an original Oxypure production. The corporate company information and serial number label on the back of the device support its originality.

    Areas of Use

    As stated on its label, this device is designed for use in the technical service and maintenance operations of “Oxygen Concentrator Only” devices. The primary functions of the device are as follows:

    • To measure the oxygen purity (%) produced by Oxygen Concentrators.
    • To measure the flow rate (LPM – Liters/minute) of the gas coming from the device.
    • To measure the output pressure (PSI).

    With these features, it is suitable for testing and calibration purposes by medical device technical services, hospital biomedical units, and companies selling respiratory devices.

    Quantity Information

    The visuals show 1 Oxypure analyzer device and 1 transparent connecting hose attached to the device. The product’s original box is also visible in the background.

    General Condition

    Cosmetically, the device is in new or near-new condition. No yellowing, dirt, or signs of use are visible on its outer casing. The screen glass is clean. The “GEZ SAĞLIK QUALITY CONTROL” label on the side is undamaged, indicating that the device has not been opened or subjected to unauthorized intervention. The device was shown in working condition.

    Physical Deformation

    No cracks, breaks, dents, or deep scratches were detected on the product’s gray/white plastic casing. The blue label where the keypad is located (or rather, the indicator panel below the information screen) is clean and has not peeled off. The overall integrity of the device is maintained.

    Mechanical Components

    The black on/off (I/O) switch located on the right side of the product appears intact. The metal (barbed) and plastic inlet ports on the top of the device are in proper form. No signs of mechanical damage are visible.

    Electronic Components and Screen Analysis

    The device’s screen is functional. The visuals show the screen’s blue backlight illuminated and displaying measurement values. The data on the screen is as follows:

    • 21.0 %: Oxygen ratio (Since the oxygen ratio in ambient air is 21%, it can be assumed that the device is reading correctly and its sensor is working).
    • 0.0 LPM: Flow rate (It is normal to show 0 as there is no flow input).
    • 0.0 PSI: Pressure (It is normal to show 0 as there is no pressure input).

    No dead pixels or blackouts are observed on the screen pixels.

    Accessories

    A transparent silicone/plastic tube (hose) is attached to the upper right port of the device. Other accessories that may come out of the box (if any, other connecting cables or batteries) are not visible in the images; only the device and the tube attached to it have been analyzed.

    Battery Status

    The label on the front of the device states “Approximately 200 measurements with 9V battery” (or a similar battery description; although the text is very small, it is clear that it is 9V). There is a battery compartment cover on the back of the device. Since the device’s screen is on, it contains a battery that is powering the device.

    Label and Technical Data

    Important technical information found on the labels of the device is listed below:

    Serial Number and Lot Information:

    • Serial Number (S/N): 21V013T 205 (Matches on device back and box).
    • Barcode (Box): 21V013T 205.
    • EAN/GTIN Barcode: 8681371820385.

    Measurement Ranges (Front Label Information):

    • Oxygen: 21% – 95.6%
    • Flow: 0 – 10 L/min
    • Maximum Pressure: 21 psi

    Warnings (Front Label Information):

    • Use only for Oxygen Concentrators.
    • Do not measure with water under any circumstances.
    • Use the left inlet for pressure measurement.

    Size and Compatibility

    The product is an ergonomic size that can be held with one hand (handheld). The device has hose inlets compatible with standard oxygen concentrator outlets.

    Year of Manufacture

    The beginning “21” in the serial number (21V013T…) may indicate a manufacturing year of 2021 according to industrial standards, but an explicit “Production Date” is not written on the label regarding this.

    Current Faults and Potential Risks

    The visuals do not show any physical evidence of the device being faulty or any error codes (Error, etc.) on the screen. The screen indicates that the sensor is active by correctly reading the ambient air (21%).

    Important Note: The warning “Do not measure with water under any circumstances” stated on the front label is critical. Since the device’s sensors are sensitive to moisture, there is a risk of sensor malfunction if used with concentrators equipped with a humidifier (water tank). However, currently, no rust or liquid contact marks are visible on the device; its condition is very good.