Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.
Report date: 07.05.2026
Report code: 1778154564
Topcon KR-8800 Auto Kerato-Refractometer Analysis Report
Device Identification
The device in the images is a Topcon KR-8800 Auto Kerato-Refractometer used in ophthalmological examinations. The device is positioned on a table and consists of a chin rest, forehead rest, measuring head, control panel, and an integrated printer.
Brand and Model
The brand of the device is Topcon, and the model is KR-8800. This information is clearly readable from the logo on the front of the device and the model labels on the sides.
Authenticity
The quality of the logos on the device, the placement of the labels, the material craftsmanship, and the overall design indicate that the product is an original Topcon device.
Usage Areas
This device is used by ophthalmologists and optometrists to automatically measure patients’ refractive errors (myopia, hyperopia, astigmatism) and corneal curvature (keratometry). It is a fundamental diagnostic tool for determining eyeglass and contact lens prescriptions.
Quantity Information
There is 1 Topcon KR-8800 device in the images. There is some hygienic paper on the chin rest of the device.
General Condition
The general condition of the device appears to be good and clean. Although it is a used device, it gives the impression of being well-maintained and in high condition.
Physical Deformation
No noticeable scratches, dents, cracks, or discoloration have been detected on the outer casing, screen, or control panel of the device. The plastic components maintain their integrity.
Mechanical Components
The patient chin rest, forehead rest, the joystick that provides movement for the measuring head, and other adjustment knobs appear to be sturdy. There are no visible issues with the mechanical parts.
Electronic Components
Since the device’s screen is off, there is no visual data regarding its electronic status. However, the fact that the integrated printer has produced a printout indicates that the device is at least partially functional.
Accessories
There is an integrated thermal printer on the device, and a test printout from the printer is visible. Hygienic papers are present on the chin rest. There are power input, fuse slots, and data terminal sockets (IN, OUT) on the back and sides of the device. The power cable or other connection cables are not present in the images.
Battery Status
The device is designed to operate by connecting directly to the mains power. No internal or external battery system has been detected from the images.
Label Information
The label on the side of the device contains the following information:
- Model: KR-8800
- Serial Number: 4116648
- Manufacturer: TOPCON CORPORATION
Additionally, there are various warning labels and technical symbols on the device.
Screen Analysis
The device’s screen is off; therefore, no analysis could be performed regarding the text or menus on the screen.
Size and Compatibility
There is no specific information in the image regarding the size of the device or patient compatibility (infant/child/adult). However, it is understood that it can adapt to different facial structures thanks to the adjustable chin rest and forehead rest.
Year of Manufacture
The exact year of manufacture of the device could not be determined from the labels or the printer output in the images. The date on the printer output (APR. 05. 2023) indicates the date the test was performed, not the year of manufacture of the device.
Documents
There is no invoice or warranty certificate for the device in the images.
Usage Duration
There is no information regarding the total usage hours or duration of the device in the images.
Existing Fault
There is no clear evidence in the images, such as broken parts or error messages, indicating that the device is faulty.
Potential Risk of Failure
The general condition of the device is good. No situation that could pose a potential risk of failure, such as severe wear, rust, or cable damage, has been observed in the images.