Objective AI Report
Disclaimer: I am Medbidding AI. I am an unbiased AI agent. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.
Report date: 21.10.2026
Report code: 1792586953
Carestream CR Cassette 35 x 43 cm / 14 x 17 in. X-ray Cassette Analysis Report
Device Identification and Basic Information
The product examined in the images is an X-ray cassette used in medical imaging systems. The brand of the product is Carestream, and the model is labeled as CARESTREAM CR Cassette 35 x 43 cm / 14 x 17 in. on the label.
- Device Identification: It is a computed radiography cassette used in radiology departments.
- Brand and Model: Carestream CARESTREAM CR Cassette 35 x 43 cm / 14 x 17 in.
- Authenticity: Upon examination of the original labels, barcodes, CE conformity mark, and brand logos on the product, it is observed to be authentic.
Usage Areas and Compatibility
This product is used in clinical and hospital environments for the radiological imaging of patients, compatible with X-ray systems.
- Usage Areas: It is used to house the imaging plate and transfer it to the scanner during radiography procedures with X-ray systems.
- Dimensions and Compatibility: The physical dimensions of the product are stated on the label as 35 x 43 cm / 14 x 17 in.
Quantity Information and Physical Condition
The images show a total of 1 main X-ray cassette and 1 flexible phosphor screen (Flexible Phosphor Screen GP-2) used with the cassette.
- Quantity Information: There is 1 main cassette and 1 internal screen present in the images.
- General Condition: The product is in used condition, with slight signs of wear and dust accumulation on the outer surface.
- Physical Deformation: There are slight superficial scratches and marks on the outer metal frame and the rear panel of the cassette.
- Mechanical Components: There are no visible fractures or functional issues with the cassette’s closing mechanism, locking tabs, or hinges.
Electronics and Battery Status
The examined product does not contain any electronic components or internal batteries; it is a purely mechanical and passive medical accessory.
- Electronic Components: As there are no electronic parts in the product, there is no electronic assembly.
- Battery Status: There is no internal or external battery in the product shown in the images.
Accessories and Label Inventory
Various technical labels, barcodes, and usage instructions are located on the rear surface and inside the product.
- Accessories: The Flexible Phosphor Screen GP-2 accessory located inside the cassette is present.
- Label and Text Inventory: The legible text on the labels is as follows: Carestream, CARESTREAM CR Cassette 35 x 43 cm / 14 x 17 in., P/N 8J3664B, CE, Made in Malaysia for Carestream Health, Inc., 150 Verona Street Rochester, New York 14608 Carestream Health, Inc. 2011, Installation Date, Cassette Number, Flexible Phosphor Screen GP-2, 9G74638, P/N 6J2516, Rev. A, and orientation text for the patient positioning diagram. These labels indicate the product’s part number, place of manufacture, compliant standards, and traceability information.
Display, Documents, and Usage Duration
Due to the nature of the product, it does not have any electronic display, usage hour counter, or printed invoice.
- Display Analysis: There is no display on the product.
- Documents: No invoice, warranty certificate, or user manual is present in the images.
- Usage Duration: There is no digital or mechanical counter indicating the usage duration or operating hours.
Fault and Risk Assessment
As a result of the visual analysis of the product, no clear fault or risk factor that would hinder its functionality has been detected.
- Existing Fault: There is no evidence of broken parts, disconnected components, or clear faults in the images.
- Potential Fault Risk: Apart from slight marks on the surface, no serious wear or risk has been observed; its condition is moderate.
- Year of Manufacture: The year 2011 on the label indicates the production period of the product.