Secondhand Keeler Cryomatic Cryotherapy Device

, , ,

Price: USD$ 5.400,00 Approx: 243.000,00 TL

Sold Out

Objective AI Report

Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.

Report date: 27.08.2025

Keeler Cryomatic Cryotherapy Device Analysis Report

Device Description and Area of Use

The product shown in the images is a cryotherapy (freezing treatment) device used in ophthalmology. The device consists of a main console mounted on a wheeled stand and probes connected to this console. Such devices are used to freeze specific tissue areas in the treatment of eye diseases like retinal detachment. The device is designed to be easily moved in a clinical setting on a stand.

Brand and Model Identification

As a result of detailed examinations, the device’s brand has been clearly identified as Keeler, and its model as Cryomatic. This information is clearly written on the control panel located on the front surface of the device.

General Condition and State

The product is generally a used device and shows signs of wear and tear in places. While the main console and stand of the device do not show significant damage that would affect functionality, some cosmetic flaws are noticeable upon close inspection. The general condition of the device is considered normal for a used medical device.

Physical and Mechanical Deformation

Physical wear and deformations have been observed in various parts of the device and its stand. These conditions are detailed below:

  • Main Console: There is no significant deformation on the device’s silver-colored main casing and white front panel frame. The screen surface appears clean. Small scratches may be present on the rear panel and sides.
  • Transport Stand: On the white metal stand, especially on the base and edges, there are paint chips and small scratches. The multi-socket unit and probe holders located on the stand appear functional. The stand has wheels and is understood to be mobile.
  • Accessories: No significant crushing or breakage has been observed on the cables. However, the disorganized state of the cables suggests a lack of care during storage.

Electronic and Technical Components

Visual evidence regarding the device’s electronic components is limited, but the following analysis has been made based on the available details:

  • Screen: The device’s front panel features a digital screen. Since the device is not shown in operation in the images, its functionality cannot be commented on, but no cracks or deep scratches are visible on the screen glass.
  • Inputs and Outputs: The device’s rear panel contains various gas and probe connection ports. No visible damage or rust has been detected in these ports.
  • Control Knob: The blue circular control knob located to the right of the screen is physically in place.
  • On-Stand Socket Group: A triple socket group is located on the transport stand. The interior parts of these sockets appear clean.

Accessories and Quantity Information

The product and its accessories shown in the images are listed below:

  • Main Device: 1 Keeler Cryomatic console.
  • Transport Stand: 1 wheeled metal stand.
  • Cryotherapy Probe: 1 treatment probe with a metal tip and its cable, connected to the main device.
  • Foot Pedal: 1 metal foot pedal used to control gas flow during treatment.
  • Other Cables: Various connection and power cables are present.

No additional accessories such as a gas cylinder or external power supply are seen in the images.

Label Information

Information read from the label on the device’s rear panel is limited. While the small text on the label cannot be fully deciphered, the phrase “CE 2005” is noteworthy. Specific information such as serial number, REF code, or lot number cannot be clearly read from the images.

Potential Malfunction Risk

The paint chips on the device’s stand and its overall used appearance are cosmetic flaws and do not directly pose a malfunction risk. The disorganized storage of cables may lead to a risk of poor contact at connection points over time, but no severe damage like crushing is observed on the cables in their current state. Based on the general structure of the product, there is no significant evidence indicating an immediate malfunction risk in its mechanical or electronic components. The device’s condition suggests that it could be used for a long time with regular maintenance.