Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.
Report date: 04.10.2025
Cardioline Delta 1 Plus ECG Device Analysis Report
Product Description and Brand Model
The device shown in the visuals is an electrocardiography (ECG) machine. The Cardioline brand name and the Delta 1 Plus model name are clearly legible on the device’s front panel and upper casing, respectively. The device is a medical instrument used to measure and record the electrical activity of the heart. Judging by the logo, font characters, and overall craftsmanship quality in the visuals, the product is deemed to be original.
General Condition and Physical Assessment
The device is generally in a used condition. There is noticeable yellowing in the plastic parts of its casing, which has occurred over time. Other than this, no serious cracks, fractures, or dents were observed on the casing. There are only minor scratches and small stains on the corners and surface due to usage. The device’s keypad and screen appear physically intact.
- Casing: The white plastic casing shows general yellowing and minor scratches in places.
- Screen: There are no cracks or deep scratches on the screen.
- Keypad: All buttons on the control panel are in place and physically in good condition.
- Printer Section: The cover of the paper output mechanism appears intact.
Technical and Operational Analysis
The visual shows the device’s screen is on and displays “BATTERY TEST”. This indicates that the device’s electronic components are functional and receiving power. The green LED light illuminated on the control panel also confirms that the device is active. It is understood from the screen display that the device has an internal battery; however, no comment can be made regarding the battery’s current performance or lifespan based on the visual.
- Quantity Information: Only 1 ECG device is present in the visuals.
- Accessories: No cables, electrodes, or other accessories belonging to the device are present in the visuals. Therefore, it is understood that its accessories are missing.
- Screen: The small-sized liquid crystal display (LCD) is operational and displaying the “BATTERY TEST” text.
- Mechanical Components: No visible issues are found in mechanical parts such as the keypad and printer cover.
Label Information and Warnings
Various warning labels and a calibration label are located on the upper part of the device. The information obtained from these labels is listed below.
- Calibration Label:
- Company: BIOTEST CALIBRATION
- Report No: 2019020904
- Application Date: February 2019
- Validity Date: February 2020
- Safety Warnings: Standard safety information is present on the device under the English headings “DANGER”, “CAUTION”, and “WARNING”, indicating that it should not be used in environments with flammable anesthetics, warning of electric shock risk, and stating that intervention should only be carried out by authorized personnel.
Conclusion and Potential Risks
This device is a used Cardioline Delta 1 Plus ECG machine that appears to be in working condition. The yellowing of its casing and minor scratches are cosmetic flaws, and there are no obvious signs of physical damage or malfunction that would affect its fundamental functionality. However, the most critical point is that the validity date on the device’s calibration label expired in February 2020. This implies that the accuracy of the device’s measurements cannot be guaranteed. Therefore, before the product is used for medical purposes, it must be inspected and recalibrated by an authorized service center. The absence of accessories is another significant shortcoming.