Sold Out

Whatsapp »
SKU: MB33CV26HAI

Secondhand Fukuda Cardimax FX-121 1 Channel ECG Device

Price: USD$ 270,00 Approx: 11.880,00 TL

, , ,

Sold Out

Don't Want To Buy At This Price?

Sorry. This product has been sold. You cannot bid. Please check out other products.

Ask a Question

    Fill in the form below to send us your message. Click the button and wait. We will contact you as soon as possible.


    * We kindly ask you to write your Whatsapp number with the country code so that we can contact you quickly.

    Click once and wait.

    Payment

    No additional fees, full assurance. We provide complete financial and operational security in secondhand medical device trading. For this, we offer the "Secure Payment" service. This free service protects the rights of both parties by securing the buyer's money and the seller's product. The Secure Payment system is a standard assurance mechanism offered by Medbidding. For additional information, review the "services" page.

    There is no cash on delivery order system on the Medbidding platform. For payments to be made by credit card, the product to be purchased must comply with this payment method. You can contact us to get information about this. We would be happy to assist you.

    For payments made outside of Turkiye, you can choose bank transfer, credit card, Western Union or cryptocurrency options. Installment options are not currently available for credit cards other than Turkish banks.

    Shipping

    Free Shipping Conditions

    You can benefit from our FREE SHIPPING campaign for your purchases in this category. Medbidding covers all shipping costs for both the buyer and the seller on orders that meet the conditions below. For all international sales and domestic sales within Turkiye that do not meet these conditions, Medbidding’s standard shipping procedures will apply.

    Conditions

    • The product must be sold for $350 USD or more.
    • Both the buyer and the seller must be located in Turkiye.

    Standard Shipping Conditions

    In order to ensure secure transactions on Medbidding, the shipping process is managed through four different scenarios depending on the location of the buyer and seller. Free shipping is available for some categories. The terms below apply to all categories unless otherwise stated.

    Buyer and Seller in Turkiye

    • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
    • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

    Buyer Outside of Turkiye, Seller in Turkiye

    • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
    • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

    Buyer in Turkiye, Seller Outside Turkiye

    • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
    • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

    Buyer and Seller Outside Turkiye

    • Technical Inspection: Technical inspections are performed by our business partner in the seller's country (where available) or by our engineers via remote video call.
    • Seller → Buyer: The seller packages the product and sends it to the buyer's address. The seller is responsible for this shipping cost.

    Objective AI Report

    Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.

    Report date: 23.11.2025

    FUKUDA DENSHI CARDIMAX FX-121 Electrocardiograph Device Analysis Report

    Brand, Model, and Device Identification

    As a result of the visual analysis, the main device displayed was identified as an electrocardiography (ECG) device. Based on the markings on the device’s front panel and user manual, its brand was confirmed to be FUKUDA DENSHI, its product series CARDIMAX, and its model FX-121. The device was observed to be a portable, compact model with an integrated handle and a built-in printer.

    Visual Condition and Physical State

    The device casing is a typical medical device beige/cream color. However, there is a noticeable color change (yellowing) on the device’s top cover and plastic surfaces around the keypad, which has occurred over time. A tonal difference is evident between the lower part of the casing and the top cover where the paper tray is located; this indicates that the device has been exposed to light for a certain period or has experienced material aging due to its age of use.

    The front panel, keypad, and indicator LEDs are in a clean condition. No wear such as fading or illegibility is observed on the buttons. Mechanically, the paper tray cover or roll was viewed in an open/empty position. No prominent deep scratches, cracks, or breaks were detected on the outer casing.

    Technical Details and Front Panel Analysis

    A detailed examination of the device’s front control panel revealed the following technical function buttons and indicators:

    • Lead Indicators (LED): LED lights marked STD, I, II, III, aVR, aVL, aVF, V1, V2, V3, V4, V5, V6 are present, indicating that the device can perform standard 12-lead ECGs.
    • Sensitivity Adjustment: Indicators with 1/2, 1, 2 options and an adjustment button are present.
    • Speed and Filter Buttons: Buttons with symbols for paper feed speed or filtering are visible.
    • Calibration and Control: A “1mV” button is present for providing a calibration signal. Additionally, there are buttons for paper feed (indicated by an arrow), centering (reset), and Start/Stop (green button).

    Accessories and Ancillary Products

    Numerous accessories are provided with the device in the visuals. These accessories include:

    • Patient Cable: A thick gray main cable connected to the main unit and a patient connection set with multiple leads at its end are present. The model number “CP-10J” and the “FUKUDA” logo are clearly visible on the splitter part of the cable.
    • Limb (Clip) Electrodes: Green, clip-type electrodes are visible in the visuals. In one visual, these items are shown as 2 units in a foam slot, and in another, next to a green box (with TE-38 and Japanese characters, translated as “TE-38 Clip Electrodes” according to the visual’s English text).
    • Chest (Suction) Electrodes: Among the cable harness, vacuum-type (suction type) metal electrodes with green rubber bulbs are present. A separate small green box contains the inscription “SUCTION TYPE CHEST ELECTRODE”.
    • Power Cable: A gray power cable, used for the device’s mains connection, with a standard European type (Schuko-like) plug at its end, is present.
    • Grounding Cable: Inside the accessory box, a yellow-green external grounding (equipotential) cable with a clamp at one end is found.
    • Thermal Paper: At least 3 rolls of thermal printer paper (with a perforated core), packaged or in transparent wrapping, are visible.

    Documents and Label Information

    The set includes printed materials, understood to be original, related to the device’s use:

    • Operation Manual: A yellow-covered English booklet titled “ELECTROCARDIOGRAPH CARDIMAX FX-121 OPERATION MANUAL” is present. The inscription “FUKUDA DENSHI CO., LTD.” is located on the manual.
    • Accessory Boxes: Original cardboard boxes for some of the accessories are present (the box coded TE-38 and the Chest electrode box).

    Originality and General Assessment

    The compatibility of the device and its accompanying accessories (user manual, logos on the cable, electrode boxes) indicates that the product is an original FUKUDA DENSHI set. The device visually maintains its integrity. Although a clear label date for the manufacturing year is not legible, considering the device’s design, accessory codes such as “CP-10J,” and plastic yellowing, it is understood to be an older production. No active screen display or output indicating the device is operational is found in the visuals; therefore, no comment can be made about its electronic functionality, but physically it appears to be a complete set (device + all cables + electrodes + manual + paper).