Ready For Sale
Secondhand Medwelt ECG-100G 1 Channel ECG Device
Price: USD$ 140,00 Approx: 6.300,00 TL
Ready For Sale
Ask a Question
Payment
No additional fees, full assurance. We provide complete financial and operational security in secondhand medical device trading. For this, we offer the "Secure Payment" service. This free service protects the rights of both parties by securing the buyer's money and the seller's product. The Secure Payment system is a standard assurance mechanism offered by Medbidding. For additional information, review the "services" page.
There is no cash on delivery order system on the Medbidding platform. For payments to be made by credit card, the product to be purchased must comply with this payment method. You can contact us to get information about this. We would be happy to assist you.
For payments made outside of Turkiye, you can choose bank transfer, credit card, Western Union or cryptocurrency options. Installment options are not currently available for credit cards other than Turkish banks.
Shipping
Free Shipping Conditions
You can benefit from our FREE SHIPPING campaign for your purchases in this category. Medbidding covers all shipping costs for both the buyer and the seller on orders that meet the conditions below. For all international sales and domestic sales within Turkiye that do not meet these conditions, Medbidding’s standard shipping procedures will apply.
Conditions
- The product must be sold for $350 USD or more.
- Both the buyer and the seller must be located in Turkiye.
Standard Shipping Conditions
In order to ensure secure transactions on Medbidding, the shipping process is managed through four different scenarios depending on the location of the buyer and seller. Free shipping is available for some categories. The terms below apply to all categories unless otherwise stated.
Buyer and Seller in Turkiye
- Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
- Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.
Buyer Outside Turkiye, Seller in Turkiye
- Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
- Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.
Buyer in Turkiye, Seller Outside Turkiye
- Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
- Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.
Buyer and Seller Outside Turkiye
If there is a local operation center in the seller's country:
- Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
- Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.
If there is no operation center in the seller's country:
- Technical Inspection: Inspections are performed by our engineers via remote video call.
- Seller → Buyer: The seller packages the product and sends it directly to the buyer's address. The seller is responsible for this shipping cost.
Objective AI Report
Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.
Report date: 19.02.2026
Analysis Report of Medwelt Digital Single Channel ECG Device
Device Identification, Brand and Model
The device shown in the visuals is a single-channel electrocardiogram (ECG) device used for medical diagnostic purposes. As a result of the detailed examination, the device’s identification information is as follows:
- Brand: Medwelt (Clearly indicated with a red and blue logo on the top left corner of the device).
- Model: The inscription Digital Single Channel ECG is located on the front of the device, just below the screen. Apart from this inscription, no specific alphanumeric model code (such as ECG-100G) is found on the top surface of the device in the visual. Therefore, the model identification has been made with the phrase “Digital Single Channel ECG” written on the product.
- Device Type: Single-channel, portable digital ECG device.
Visual Details and General Condition
The cosmetic condition of the device appears clean and well-maintained based on the examination of the visuals. Although it is in second-hand status, no yellowing or significant deformation is noticeable on its outer casing.
- Casing Condition: The device’s outer plastic is white/cream colored, and its color integrity has been preserved. No noticeable deep scratches, breaks, or cracks are present.
- Screen: A monochrome (LCD) graphic screen is located on the right side of the device. Since the device is off, no dead pixels or text analysis can be performed on the screen, but no physical damage is visible on the screen surface.
- Keypad: A membrane-type control panel is located on the bottom right side of the device on a blue background. The symbols and texts on the buttons (ON/OFF, START/STOP, MODE, PRINT, SPEED, SENS, FILTER) are not erased, remaining clear and legible. Signs of wear are low.
Mechanical and Electronic Components
Based on visual data, the physical integrity and mechanical parts of the device have been examined:
- Printer Section: The thermal printer compartment is located on the left side of the device. The paper compartment lid is closed and fully seated. No hinge breakage or lid misalignment has been observed.
- Sockets and Connections: Cable outputs that could be used for power or data transfer are partially visible on the side of the device. It is estimated that the main patient cable (ECG cable) input is on the side of the device.
Accessories and Hardware
The accessories displayed with the device are as follows:
- Clamp Electrodes (Limb Electrodes): Blue, clamp-type ECG limb electrodes are seen on the device. Although at least 2 clamps are clearly visible in the image, it is highly probable that they are present as a set (usually 4 pieces) within the cable entanglement. While a detailed comment on rust/oxidation of the spring mechanism and metal contact surfaces of the clamps cannot be made, their plastic parts appear intact.
Quantity Information: The visual shows 1 Medwelt ECG device and an ECG clamp electrode set resting on the device.
Label and Warning Information
Labels and written warnings on the device provide important clues about the product’s history and safety:
- Service and Inspection Label: On the left side of the keypad, there is a yellow, circular label. It contains the inscription “KONTROL EDİLMİŞTİR – BE-SA” (INSPECTED – BE-SA) and a checkmark. This indicates that the device has previously undergone technical service, maintenance, or calibration control. This is a confidence-boosting factor for second-hand purchases.
- Safety Warning: On the bottom left part of the device, there is a safety warning in English: “DANGER: Possible explosion hazard if used in the presence of flammable anesthetics.” (TEHLİKE: Yanıcı anesteziklerin varlığında kullanılırsa olası patlama tehlikesi). This is a standard medical device safety statement.
Areas of Use
The Medwelt Digital Single Channel ECG device is used to print the heart’s electrical activity on paper or display it on a screen. Its primary areas of use are:
- Family Health Centers and Polyclinics (For routine check-ups).
- Emergency Departments and Ambulances (For rapid rhythm analysis).
- Cardiology Practices.
- Veterinary Clinics (With compatible attachments).
Potential Failure Risk and Evaluation
No significant damage that would prevent the device from operating (broken casing, detached keypad, screen crack) has been detected in the visuals. The yellow inspection label indicates that the device has been examined by a professional technical service, which is a positive point. However:
- It should be noted that the metal parts of the clamp electrodes may oxidize over time and should be checked for hygiene.
- Although the battery status cannot be determined from the visual, it is common for internal batteries in such portable devices to experience performance degradation over time.
Overall, the product’s condition can be classified as “Good/Well-maintained” visually.