Secondhand Covidien ForceTriad Electrocautery Machine

SKU: MB8FJG31W6I
1 views

Ready for Sale

, , , ,

Medbidding Video Check

Matching Service

Price: USD$ 8,000.00 Approx: 400,000.00 TL
Bid

Objective AI Report

Disclaimer: I am Medbidding AI. I am an unbiased AI agent. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.

Report date: 03.11.2026
Report code: 1793692474

Covidien ForceTriad Energy Platform and Cart Analysis Report

Device Identification and Basic Information

The product examined in the images is an energy platform used in medical surgical operations and the specialized transport cart on which this device is positioned. The main body of the device features various ports, control screens, and keypads on its front panel. Beneath the device, there is a blue, three-shelf transport cart with wheels. The brand of the device is stated as Covidien, and the model is specified as ForceTriad on the label.

Brand, Model, and Authenticity Assessment

The Covidien brand logo and ForceTriad model name are clearly visible on the front face and the rear label of the product. The serial number, REF code, safety symbols, and manufacturing year information on the rear technical label indicate that the device is an original piece of medical equipment. The logo quality and label printing standards match the characteristics of the original product perfectly.

Usage Areas

The device is used in operating rooms and surgical procedures to perform tissue cutting, coagulation (stopping bleeding), and sealing operations. It is suitable for use in general surgery, laparoscopic surgery, and similar branches. The transport cart provided with the product ensures the safe transport of the device and its mobile positioning within the surgical environment.

Quantity Information

The images show one Covidien ForceTriad energy platform, one blue transport cart specific to this device, one purple foot pedal positioned on the cart shelf, and cables attached to the rear panel.

General Status and Condition

The device and the transport cart are in a generally clean and orderly condition. While there are minor signs of use on the outer plastic and metal components consistent with operating room usage, the overall integrity is maintained. The device is in a physical form suitable for operational status.

Physical Deformation

There are no noticeable deep cracks, breaks, dents, or color fading on the outer casing of the device, the screen panel, or the blue body of the transport cart. The surfaces exhibit minimal superficial marks resulting from routine use.

Mechanical Components

The wheels of the transport cart, shelf mechanisms, cable hanging apparatus, and the physical button groups and socket slots on the front panel of the device are mechanically intact. No visually detectable defects are present in the moving parts or wheel connections.

Electronic Components

The active screen modules, digital display windows, touch and push-button areas, and socket inputs are visible on the front panel of the device. The rear panel features a standard IEC power input socket and an equipotential connection pin.

Accessory Inventory

The images include the device’s transport cart, cable management hooks integrated into the cart shelves, one purple foot pedal resting on the middle shelf, and the power cable connected to the device. No sterile or consumable materials with expiration dates are present in the image.

Battery Status

There is no data or battery compartment related to an internal or external battery for the device in the images. The device is designed to operate directly via mains electricity.

Label and Text Inventory

The following texts and values are readable on the technical label located on the rear panel of the device:

  • Covidien ForceTriad Energy Platform
  • REF ForceTriad
  • 100-240 V~, 50/60 Hz; 800-2080 VA: Indicates the device’s operating voltage, frequency, and power consumption range.
  • Bipol: 95 W / 100 Ohm
  • Seal: 350 W / 20 Ohm
  • Monopol: 300 W / 300 Ohm
  • HWD: 200 W / 300 Ohm
  • 472 KHz Int. 10s / 30s
  • 2011 Covidien. Made in USA.
  • Covidien llc, 15 Hampshire Street, Mansfield, MA 02048 USA.
  • EC REP Covidien Ireland Limited, IDA Business & Technology Park, Tullamore. 1039982
  • ETL Intertek 3164410
  • Conforms to: UL STD 60601-1, Certified: CSA STD C22.2 NO. 601.1
  • CE 0086
  • SN T5B44979EX
  • 2015-02
  • Warning: Risk of Fire. Replace Fuse as Marked. 250V, F8.0A (100-240): Specifies the technical current and voltage values to be followed during fuse replacement.
  • Avertissement: Risque du feu. Remplacez les fusibles comme marqués. 250 V F8.0A (100-240)

The front panel contains the inscriptions Covidien, ForceTriad, Monopolar 1, Monopolar 2, LigaSure 1, LigaSure 2, and warning symbols.

Screen Analysis

The digital screen modules located on the upper front part of the device are in an active state. Power levels, mode selection buttons (Cut, Coag, Fulg, Spray, Blend), menu tab headers, and numerical setting indicators (e.g., the value 15) are clearly readable on the screens.

Dimensions and Compatibility

There is no direct millimetric measurement information regarding the physical dimensions or weight of the device in the images. It is understood from the visual that the product, along with its transport cart, has standard operating room space compatibility.

Manufacturing Year

The 2015-02 notation on the rear technical label and the 2011 Covidien copyright year information are present. These data shed light on the production period of the device.

Documents

No external documents such as invoices, printed warranty certificates, or user manuals are present in the images.

Usage Duration

There is no counter data in the images showing the total operating hours or usage duration of the device.

Existing Faults

Optical inspection obtained from the images reveals no clear evidence of faults such as broken parts, severed cables, error messages, or missing components.

Potential Fault Risk

No concrete risks such as excessive rusting, severe casing deformation, or crushed cables were observed in the images. The general condition of the device is at a good level.