Objective AI Report
Disclaimer: I am Medbidding AI. I am an unbiased AI agent. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.
Report date: 10.11.2026
Report code: 1794317602
Valleylab Force Triad Device Analysis Report
Device Identification and Brand Model Information
The device shown in the images is an electrosurgical unit used in medical surgical applications. According to the inscriptions on the upper body panel and the front surface, the brand is Valleylab, and the model is indicated by FORCE EZ or FORCE TRIAD labels, with the FORCE TRIAD inscription clearly legible on the front panel.
- Brand: Valleylab
- Model: FORCE TRIAD
- Device Type: Electrosurgical Unit
- Authenticity: The device’s body design, front panel layout, screen structure, and brand logos are consistent with original manufacturer standards.
Usage Areas and Purpose
This device is used in operating rooms and surgical procedures to perform tissue cutting, coagulation, and vessel sealing. It is suitable for use by surgeons in general surgery, plastic surgery, and similar branches.
Quantity Information and General Condition
- Quantity Information: The images show a single main device and some paper documents placed on it. No other accessories or additional parts are present.
- General Condition: The device is in used condition. There are signs of wear on the body surfaces and the upper blue cover section.
Physical Deformation and Mechanical Components
- Physical Deformation: There are various scratches and surface abrasions on the upper blue body surface of the device. Slight color fading and usage-related marks are visible on the side panels.
- Mechanical Components: The socket slots, power switch, and connection ports on the front panel are in place. No physical breakage has been detected on the screen frames.
Electronic Components and Screen Analysis
- Electronic Components: The power switch, monopolar and bipolar input ports, and sealing slots are located on the front. The internal condition of the device’s electronic components cannot be directly tested from the image.
- Screen Analysis: There are three screen panels positioned side by side on the upper front part of the device. The screens are turned off, and no error codes or menu text are visible.
Accessories and Connection Ports
- Accessories: The device’s external cable, handpiece, or foot pedal are not visible in the images. Only paper documents are present on the device.
- Connection Ports: The front panel features Monopolar 1, Monopolar 2, REM port, UFP input, Bipolar output, and LigaSure 1 and LigaSure 2 slots. The port entry slots are in place.
Battery Status, Dimensions, and Compatibility
- Battery Status: There is no internal or external battery unit visible in the images; the device is designed to operate directly via mains electricity.
- Dimensions and Compatibility: Label information regarding the device’s dimensions or weight is not present in the image. It is of a size suitable for use on a medical table or stand.
Label and Inscription Inventory
The inscriptions and label data read from the images are as follows:
- The FORCE TRIAD inscription and logo are located on the top left of the front panel.
- Below the ports on the front panel, the inscriptions Monopolar 1, Monopolar 2, UFP, REM, Bipolar, LigaSure 1, and LigaSure 2 are present.
- International electrical hazard and warning symbols are located on the right side of the front panel.
- The Valleylab brand and the FORCE TRIAD inscription in large font are located on the top left blue cover.
- Since the technical labels on the rear or bottom panel are not visible in the images, information regarding the serial number, voltage, current, frequency, power, fuse ratings, and place of manufacture cannot be read.
Year of Manufacture and Usage Duration
- Year of Manufacture: There is no label or date stamp indicating the year of manufacture in the images. A precise estimate of the production year cannot be made based on the device’s design lines and serial structure.
- Usage Duration: Since the screens are off and the operating hour counter is not visible, the total operating time of the device cannot be determined.
Documents and Current Status
- Documents: There is a file or paper document with a blue cover left on the top of the device, but its content and details cannot be read.
- Current Fault: Visual inspection reveals no clear evidence of a fault such as a broken casing or severed cables; however, since the screens are off and the device has not been tested, its electronic functionality is unknown.
- Potential Fault Risk: No concrete risk has been observed other than numerous superficial scratches and abrasions on the upper blue cover surface. The condition of the device is moderate.