Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.
Report date: 18.12.2025
Üzümcü EK-160 Electrocautery Device Analysis Report
Device Identification and Description
The devices in the visual are electrocautery units used for tissue cutting (cutting) and bleeding control/coagulation (coagulation) during surgical operations. The “CUT” (Cutting) and “COAG” (Coagulation) labels on the front panel of the devices, along with the electrode inputs, confirm this identification. The visual shows two main units standing side-by-side with foot pedals placed on top of them.
Brand and Model Information
A detailed examination of the products in the visuals revealed the “Üzümcü” brand logo clearly visible on the lower left corner of the front panels of the devices. The model number “EK-160” is also clearly readable on the upper left corner of the front panel. Based on these visual evidences, it has been confirmed that the devices are Üzümcü brand EK-160 model Electrocautery devices. This is not a presumptive identification; the text and logos are present in the visual.
Originality Assessment
The casing of the devices, the membrane keypad design, the position and typography of the brand logo appear to be in compliance with original Üzümcü medical device standards. No aftermarket labeling or signs of modification have been found, and the products are assessed to be original.
Areas of Use
These devices (Electrocauteries) are used during operational interventions in many medical specialties such as general surgery, dermatology, gynecology, and orthopedics. They enable tissues to be cut by burning with electric current or bleeding to be stopped. The Üzümcü EK-160 model features hardware that allows for bipolar and monopolar applications and is suitable for use in operating rooms or intervention rooms.
Quantity Information
According to visual analysis, the counted components are as follows:
- 2 units Üzümcü EK-160 Main Unit
- 2 units Foot Pedals (Footswitch) and connection cables (Placed on top of the devices)
General Condition and Cosmetic Examination
The devices are in used condition but their general condition appears clean. No significant rust, dents, or discoloration noticeable on the white metal casings have been detected. The device on the left is seen to be in working condition (due to its screen being on). The products give the impression of being stored or waiting on a shelf.
Electronics and Screen Analysis
The power button of the device on the left in the visual is in the ‘on’ position, and its digital screens are active. The findings regarding the electronic status are as follows:
- Left Device: The blue “COAG” (Coagulation) screen displays a value of “23”. The yellow “CUT” (Cutting) screen displays “rEL” or a similar character sequence, although it is not entirely clear. The LED indicators on the front panel are active.
- Right Device: Although the power switch of the device appears to be in the ‘on’ (I) position, no values are displayed on its screens. While this might suggest the device is off, in standby mode, or not visible in the photo due to screen refresh rate, there is no clear sign of activity.
Accessories and Connections
Black colored foot pedals are present on both devices. These pedals allow the surgeon to control the cautery device with their feet, without using their hands. The cables of the pedals are wrapped around the pedals and placed on top of the devices. Monopolar and Bipolar input sockets are present on the front panel of the devices, but no handpiece (cautery pencil) attached to these sockets is visible in the visual.
Potential Malfunction Risk and Warnings
While the overall condition of the devices appears good, the cables of the foot pedals on top are tightly and irregularly wrapped around the pedals. This type of storage method can lead to breakage of conductors inside the cable or damage to the outer insulation in the long term. Other than this, no deformation (cracks, breakage, etc.) that would concern the buyer has been observed on the device casing.
Manufacturing Year and Label Information
The visual angle does not allow for reading of technical labels (Serial No, Lot, Manufacturing Year) that are likely located on the back or side surfaces of the devices. Only brand, model, and functional button information is available on the front panel.