Secondhand Karl Storz Telecam DX Pal 202320 20 Endoscopy System

, , , ,

Medbidding engineers inspect before delivery.

Price: USD$ 5.000,00 Approx: 225.000,00 TL
Bid

Ready For Sale

Objective AI Report

Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.

Report date: 28.05.2026
Report code: 1779975053

Karl Storz Endoscopy System Analysis Report

Device and Accessory Identification

The images show one camera control unit, one light source, one camera head, two rigid endoscopes, one fiber optic light cable, one power cable, and one metal carrying case. Additionally, there are two empty accessory boxes on the bottom shelf of the table.

Brand and Model Information

The brand and model information of the devices in the images are as follows

  • Camera Control Unit Brand and Model Karl Storz Telecam DX Pal (Model Code: 202320 20)
  • Light Source Brand and Model Karl Storz Halogen 250-2 twin (Model Code: 201132 20)
  • Rigid Endoscope Brand and Model Karl Storz (According to the label on the box, it is 4mm in diameter, 175mm in length, and has a 0-degree angle)

Authenticity and General Condition Assessment

The logos on the devices, label designs, and the quality control approval label on the metal carrying case confirm that the products are original Karl Storz production. All equipment is in used condition. The general condition of the devices is clean and good. There are minor scratches and traces of old labels on the outer surface of the metal carrying case due to usage.

Usage Areas and Compatibility

This endoscopy system is used to provide imaging and illumination in minimally invasive surgical branches such as otorhinolaryngology, arthroscopy, and laparoscopy. The camera control unit processes the endoscopic image and transfers it to the screen. The halogen light source provides powerful illumination to the rigid endoscope with the help of a fiber optic cable. The 4mm diameter and 175mm long rigid endoscope is fully compatible with standard ENT and intra-articular imaging procedures.

Quantity Information

The total quantities of products and accessories identified in the images are listed below

  • 1 unit Karl Storz Telecam DX Pal Camera Control Unit
  • 1 unit Karl Storz Halogen 250-2 twin Light Source
  • 1 unit Karl Storz Telecam Camera Head and integrated connection cable
  • 2 units Karl Storz Rigid Endoscopes (in their protective white boxes)
  • 1 unit gray fiber optic light cable
  • 1 unit black power cable
  • 1 unit Karl Storz original metal carrying case
  • 2 units empty white accessory boxes (with black foam)

Physical and Mechanical Condition Analysis

No fractures, cracks, deep dents, or discoloration have been observed on the outer casings of the devices. The two adjustment knobs, power switch, and socket inputs on the front panel of the light source are physically intact. The power switch and socket input on the front panel of the camera control unit are complete. The locking mechanisms and carrying handle of the metal carrying case are in full working order.

Electronic Components and Cable Condition

There is no visual evidence that the devices have been powered on by connecting them to electricity. There are no signs of peeling, crushing, or breakage on the camera head cable and the fiber optic light cable. The socket inputs and connection ends are clean. No internal or external battery has been detected on the devices. The system operates directly on mains electricity.

Label and Technical Details

The label information on the products is as follows

  • Camera Control Unit Model Number 202320 20
  • Light Source Model Number 201132 20
  • Rigid Endoscope Box Label 4mm 175mm 0° / 0200E / 300.2204
  • Carrying Case Approval Label STORZ Quality Assurance Dept. (Quality Assurance Department test approval label)

Fault and Risk Assessment

There is no evidence in the images, such as broken parts or physical damage, to suggest that the devices are faulty. No significant wear or crushing has been observed on the cables and connection points. The general condition of the devices is good, and they do not pose any potential physical failure risk.