Secondhand B. Braun Diapact CRRT Hemodialysis Device
Price: USD$ 7.700,00Approx: 323.400,00 TL
Ready For Sale
Ask a Question
Objective AI Report
Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.
Report date: 24.07.2025
B. Braun Diapact CRRT Device Analysis Report
Overview and Device Description
The product shown in the images is a B. Braun brand, Diapact CRRT model continuous renal replacement therapy (CRRT) device. This device is a type of dialysis machine used for patients with acute kidney failure, particularly in intensive care units. The product consists of a main unit integrated onto a wheeled stand and an IV pole. The device’s design and logos suggest that the product is original. One main device and its associated equipment have been examined in the images.
Physical Condition and Cosmetic Assessment
The overall condition of the device is assessed as used. There is significant yellowing and discoloration on its plastic casing, especially around the screen and control panel. This condition may indicate the age of the device or its prolonged exposure to certain light conditions. Minor scratches and superficial stains were observed on the casing, but no cracks or fractures were detected. Overall, despite its cosmetic flaws, the physical integrity of the device is intact.
Mechanical and Electronic Components Analysis
Upon visual inspection of the device’s mechanical and electronic components, the following conditions were identified:
- Peristaltic Pumps: The covers and mechanisms of the three peristaltic pumps on the front panel appear to be intact.
- Control Panel and Screen: The buttons on the control panel are in good physical condition, with no tears or excessive wear. As the device’s screen is off, its operational status or display quality cannot be commented on. There are no visible scratches or cracks on the screen surface.
- Wheels: The stand on which the device is mounted has four wheels, and they appear to be functional.
- Ports and Connections: There are various sensor and set connection points on the front panel, such as PV, PSC, PD2, PA, PBE, and PD1. These ports are visually clean and undamaged.
Accessories and Equipment
The only accessory shown with the device in the images is the stainless steel IV pole mounted on it. The IV pole is in good condition, with no significant rust or deformation. The disposable patient sets, solution bags, power cord, or other external accessories required for the device’s operation are not present in the images.
Label and Technical Information
The manufacturer’s label containing information such as the device’s serial number, reference (REF) code, lot number, or year of manufacture could not be clearly viewed in the images. Therefore, this information could not be included in the report.
Potential Risk Assessment
The yellowing on the device’s casing indicates long-term use or the age of the product. Electronic and mechanical parts can wear out over time. However, no serious risk factors that would directly affect the device’s functionality, such as a broken part, a crushed cable, or rust, were observed in the images. The overall physical condition of the device is reasonable for its age. These stated potential risks are only a forecast based on visual inspection and do not imply a definite failure will occur.