Ready For Sale
Secondhand Medtronic Minimed 740G Insulin Pump
Price: USD$ 2.250,00 Approx: 99.000,00 TL
Ready For Sale
Ask a Question
Payment
No additional fees, full assurance. We provide complete financial and operational security in secondhand medical device trading. For this, we offer the "Secure Payment" service. This free service protects the rights of both parties by securing the buyer's money and the seller's product. The Secure Payment system is a standard assurance mechanism offered by Medbidding. For additional information, review the "services" page.
There is no cash on delivery order system on the Medbidding platform. For payments to be made by credit card, the product to be purchased must comply with this payment method. You can contact us to get information about this. We would be happy to assist you.
For payments made outside of Turkiye, you can choose bank transfer, credit card, Western Union or cryptocurrency options. Installment options are not currently available for credit cards other than Turkish banks.
Shipping
Standard Shipping Conditions
In order to ensure secure transactions on Medbidding, the shipping process is managed through four different scenarios depending on the location of the buyer and seller. Free shipping is available for some categories. The terms below apply to all categories unless otherwise stated.
Buyer and Seller in Turkiye
- Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
- Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.
Buyer Outside of Turkiye, Seller in Turkiye
- Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
- Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.
Buyer in Turkiye, Seller Outside Turkiye
- Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
- Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.
Buyer and Seller Outside Turkiye
- Technical Inspection: Technical inspections are performed by our business partner in the seller's country (where available) or by our engineers via remote video call.
- Seller → Buyer: The seller packages the product and sends it to the buyer's address. The seller is responsible for this shipping cost.
Objective AI Report
Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.
Report date: 16.01.2026
Medtronic MiniMed Insulin Pump and Accessories Analysis Report
Device Identification
As a result of the analysis performed on the visuals, the main product was identified as an insulin pump, which is a medical device. In addition to the device, boxes of consumables (infusion set and reservoir) necessary for the operation of this system are also seen as part of the set. The system consists of the pump device, accessories such as a protective case, tubing clamp, and separately boxed consumables.
Brand and Model
Upon examination of the inscriptions on the products and packaging details, the following brand and model information has been definitively identified:
- Main Device Brand: Medtronic
- Main Device Model Series: MiniMed
- Consumable 1 (Infusion Set): MiniMed Quick-set
- Consumable 2 (Reservoir): MiniMed Reservoir
Since no clear indication of the device’s model number (e.g., a specific code like 640G or 780G) was visually legible on the box, the model is stated as the “MiniMed” series.
Authenticity
Upon examination of the print quality of the product packaging, the correct use of “MiniMed” and “Medtronic” logos, the arrangement within the packaging (harmony of styrofoam and cardboard dividers), and the label details on the consumable boxes, the product is assessed to be an original Medtronic product.
Areas of Use
This device and its accessories are designed for use in diabetes management. The insulin pump provides continuous and adjustable insulin delivery to the body. Infusion sets (Quick-set) are used for subcutaneous insulin delivery, while reservoirs are used to store insulin placed inside the device. It is a suitable medical product for the endocrinology branch and diabetes patients.
Quantity Information
The parts identified in the visuals are:
- 1 unit of Medtronic MiniMed insulin pump device.
- 1 box of MiniMed Quick-set (quantity of contents not visible from outside the box).
- 1 box of MiniMed Reservoir (quantity of contents not visible from outside the box).
- 1 blue plastic accessory (tubing clamp/clip).
- 1 black protective case or clip (bagged next to the device).
- Numerous user manuals and warning documents.
General Condition
The device is seen in its original box. Although the box has been opened, the device’s packaging arrangement and cleanliness indicate that the product is in “new” or “like-new” condition. The lids of the consumable boxes appear closed, and their general condition is excellent.
Physical Deformation
No cracks, scratches, discoloration, or signs of wear were detected on the device’s outer casing, screen, or keypad. The black glossy surfaces appear clean.
Mechanical Components
The keypad (navigation buttons), battery compartment cover (top), and reservoir entry section (side) appear intact. No mechanical breakage or missing parts are noticeable in the visuals.
Electronic Components
The device’s screen is in the off position in the visual. There are no cracks or impact marks on the screen surface. Although electronic functionality (whether it turns on or not) cannot be tested via the visuals, its physical integrity is complete.
Accessories
Accessories are located in clear plastic bags in the lower compartment of the device box. The packaging of these accessories appears unopened.
Battery Status
Upon detailed examination of the device’s battery compartment cover, whether open or closed, no light or indicator is visible to suggest that the device is currently being operated with an internal battery. These devices typically run on AA-type batteries; however, it is not clear from the visual whether a battery is installed.
Label Information
Technical and logistical information legible on the accessories and boxes includes:
- Manufacturer: Medtronic MiniMed (Northridge, CA, USA)
- Licensee / Distributor: Medtronic Trading Ltd. (Herzliya, Israel)
- Accessory Barcode (Blue clamp package): (01)006431695235…
- Part Description: 7005153-004 C TUBING CLAMP
- Origin: Made in Singapore (label visible for Case/Clamp accessories)
Screen Analysis
The device screen is black/off. There are no error codes, warnings, or menu visuals on the screen. The screen surface is smooth.
Size and Compatibility
The device is palm-sized, portable, and suitable for use on the belt. “MiniMed” compatibility is indicated on the Quick-set and Reservoir boxes, showing that the parts form a fully compatible set with each other.
Documents
In the compartment located under the device within the box, there is a thick user manual, presumed to be multilingual (with warning texts visible in different languages), and warranty/information brochures. The documents appear unworn and complete within the box contents.
Potential Risk of Malfunction
No negative indications such as rust, liquid contact, oxidation, or dents due to dropping were observed in the visuals. Since the product appears cosmetically and structurally sound, no potential risk of malfunction is foreseen based on the visual data.