Approved

Ready For Sale

Whatsapp »
SKU: MB77S963H8Z

Secondhand Veron VRN-801 15L/min Medical Gas Cylinder With Valve Regulator

, , ,

Price: USD$ 17,00 Approx: 765,00 TL

Ready For Sale

Don't Want To Buy At This Price?

    Bid


    * We kindly ask you to write your Whatsapp number with the country code so that we can contact you quickly.

    Click once and wait.

    Ask a Question

      Fill in the form below to send us your message. Click the button and wait. We will contact you as soon as possible.


      * We kindly ask you to write your Whatsapp number with the country code so that we can contact you quickly.

      Click once and wait.

      Payment

      No additional fees, full assurance. We provide complete financial and operational security in secondhand medical device trading. For this, we offer the "Secure Payment" service. This free service protects the rights of both parties by securing the buyer's money and the seller's product. The Secure Payment system is a standard assurance mechanism offered by Medbidding. For additional information, review the "services" page.

      There is no cash on delivery order system on the Medbidding platform. For payments to be made by credit card, the product to be purchased must comply with this payment method. You can contact us to get information about this. We would be happy to assist you.

      For payments made outside of Turkiye, you can choose bank transfer, credit card, Western Union or cryptocurrency options. Installment options are not currently available for credit cards other than Turkish banks.

      Shipping

      Standard Shipping Conditions

      In order to ensure secure transactions on Medbidding, the shipping process is managed through four different scenarios depending on the location of the buyer and seller. Free shipping is available for some categories. The terms below apply to all categories unless otherwise stated.

      Buyer and Seller in Turkiye

      • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
      • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

      Buyer Outside Turkiye, Seller in Turkiye

      • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
      • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

      Buyer in Turkiye, Seller Outside Turkiye

      • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
      • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

      Buyer and Seller Outside Turkiye

      If there is a local operation center in the seller's country:

      • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
      • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

      If there is no operation center in the seller's country:

      • Technical Inspection: Inspections are performed by our engineers via remote video call.
      • Seller → Buyer: The seller packages the product and sends it directly to the buyer's address. The seller is responsible for this shipping cost.

      Objective AI Report

      Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.

      Report date: 05.03.2026

      Koyuncu Oxygen Regulator and Humidifier Set Analysis Report

      Device Identification

      The product in the image is an oxygen regulator set designed for use with medical gas cylinders, featuring an integrated flowmeter and a humidifier bottle. The system consists of a high-pressure manometer, a pressure-reducing regulator body, a flow-regulating valve flowmeter, and a humidifier water reservoir.

      Brand and Model

      Brand: KOYUNCU

      The “KOYUNCU” logo and brand are clearly legible within the product’s manometer dial. No indication of a model name has been found on the body or labels.

      Originality

      Considering the craftsmanship of the metal components, the print quality on the manometer dial, the transparency of the plastic components (humidifier bottle and flowmeter tube), and the clarity of the warning texts on them, the product is assessed to be an original production.

      Areas of Use

      This device is used to reduce pressure when connected to high-pressure oxygen cylinders and to adjust the oxygen flow delivered to the patient in liters/minute. Thanks to its built-in humidifier bottle, it humidifies dry oxygen gas, preventing dryness in the patient’s respiratory tracts. It is suitable for oxygen therapy applications in hospitals, clinics, emergency departments, and home care services.

      Quantity Information

      The image shows a single (1) assembled regulator set. The set includes a manometer, flowmeter tube, connection body, and humidifier bottle.

      Overall Condition

      The product is cosmetically in “New / Unused” or “Very Slightly Used” condition. The metallic surfaces retain their luster, and no yellowing or dullness is observed on the plastic parts.

      Physical Deformations

      No scratches, cracks, breaks, or dents have been detected on the device’s outer casing, connection nut, or plastic components. The humidifier bottle is transparent and clean.

      Mechanical Components

      The regulator connection nut (fitting), flow adjustment valve, and manometer connection appear mechanically sound. The knurled structure on the adjustment knob is clean.

      Electronic Components

      This device operates entirely on mechanical principles; it does not contain any electronic components.

      Accessories

      The image shows a humidifier bottle attached to the device. An oxygen cannula or mask is not attached to the device’s outlet (barb). The cylinder connection gasket is visible in the image.

      Label and Text Information

      The texts and technical markings identified on the device are as follows:

      • Manometer Dial: KOYUNCU brand, “EN 562” standard, pressure range (0 – 315/4500 scale – in psi/bar), brand logo.
      • Flowmeter: “O2” (Oxygen) marking on the tube, flow scale from 0 to 15 (L/min), technical note L/min 20°C 101325Pa.
      • Adjustment Valve (Blue): “O2” marking, arrow indicators showing opening direction, Turkish “AÇ” (OPEN) and “KAPA” (CLOSE) expressions.
      • Regulator Body (Blue Ring): “DO NOT USE OIL” safety warning and “230 BAR” pressure resistance indication.
      • Humidifier Bottle: “UPPER LEVEL”, “LOWER LEVEL” boundary lines, and “DISTILLED WATER PREFERRED” usage instruction.

      Battery Status

      The device has a manual mechanical structure; it does not require a battery or power supply.

      Screen Analysis

      There is no digital screen. An analog manometer gauge is present. The manometer needle is currently at the “0” position, indicating no gas input to the device or that the cylinder is closed.

      Dimensions and Compatibility

      It has a connection structure suitable for standard medical oxygen cylinder valves. The humidifier outlet has a ‘Christmas tree’ (barb) type tip structure compatible with standard oxygen hoses (cannula/mask).

      Year of Manufacture

      No direct year of manufacture information is legible on the manometer.

      Current Fault

      No broken parts, missing components, or obvious signs of malfunction are observed in the visual inspection.

      Potential Malfunction Risk

      Currently, there is no visible risk. No significant risk factors have been observed, other than the need for regular checks of gaskets to prevent oxidation of metal parts and ensure sealing. The device’s condition gives the impression that it is ready for immediate use.