Sold Out

Whatsapp »
SKU: MB4EUMO142C

2 Pieces Secondhand GE EIZO 5MP 5135407 Medical Monitor

, , , ,

Price: USD$ 2.000,00 Approx: 90.000,00 TL

Sold Out

Don't Want To Buy At This Price?

Sorry. This product has been sold. You cannot bid. Please check out other products.

Ask a Question

    Fill in the form below to send us your message. Click the button and wait. We will contact you as soon as possible.


    * We kindly ask you to write your Whatsapp number with the country code so that we can contact you quickly.

    Click once and wait.

    Payment

    No additional fees, full assurance. We provide complete financial and operational security in secondhand medical device trading. For this, we offer the "Secure Payment" service. This free service protects the rights of both parties by securing the buyer's money and the seller's product. The Secure Payment system is a standard assurance mechanism offered by Medbidding. For additional information, review the "services" page.

    There is no cash on delivery order system on the Medbidding platform. For payments to be made by credit card, the product to be purchased must comply with this payment method. You can contact us to get information about this. We would be happy to assist you.

    For payments made outside of Turkiye, you can choose bank transfer, credit card, Western Union or cryptocurrency options. Installment options are not currently available for credit cards other than Turkish banks.

    Shipping

    Standard Shipping Conditions

    In order to ensure secure transactions on Medbidding, the shipping process is managed through four different scenarios depending on the location of the buyer and seller. Free shipping is available for some categories. The terms below apply to all categories unless otherwise stated.

    Buyer and Seller in Turkiye

    • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
    • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

    Buyer Outside Turkiye, Seller in Turkiye

    • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
    • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

    Buyer in Turkiye, Seller Outside Turkiye

    • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
    • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

    Buyer and Seller Outside Turkiye

    If there is a local operation center in the seller's country:

    • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
    • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

    If there is no operation center in the seller's country:

    • Technical Inspection: Inspections are performed by our engineers via remote video call.
    • Seller → Buyer: The seller packages the product and sends it directly to the buyer's address. The seller is responsible for this shipping cost.

    Objective AI Report

    Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.

    Report date: 26.02.2026

    GE 5135407 / Siemens SMD 21500 G Medical Monitor Analysis Report

    Device Identification

    The visuals show two medical-grade LCD monitors with large casings, designed for desktop use. The devices feature a thick industrial design with backlighting and ventilation grilles. These products are not standard consumer electronics but medical workstation monitors produced for medical imaging systems (radiology, tomography, etc.).

    Brand and Model

    The data obtained as a result of detailed visual and label inspection is as follows:

    • Brand: GE (General Electric) – (Logo present on the front bezel and rear label).
    • Model No: 5135407 (GE stock/model number).
    • OEM Manufacturer/Model: Siemens SMD 21500 G (Siemens Medical Display).
    • Part Number (P/N): 6GF6201-4CC13.

    Originality

    The product’s rear label features the “Made in Germany” statement and the address of Siemens AG, Munich. The print quality of the GE logo and Siemens production labels, as well as certification marks (CE, CSA, TÜV), are in line with industrial standards. The product is an original part manufactured by Siemens as an OEM for GE medical systems.

    Areas of Use

    These monitors are designed for use in high-resolution medical imaging (PACS, CT, MRI, X-ray) workstations. They are produced to provide grayscale and detail clarity in images for diagnostic and analysis purposes. Compatible with GE medical imaging systems or independent radiology workstations.

    Quantity Information

    The visuals show a total of 2 (two) monitors and their attached stands.

    General Condition

    The devices are in used (second-hand) condition. The general integrity of the casings has been preserved, but there is superficial soiling due to long-term use and storage.

    Physical Deformation

    • Casing: No cracks, breaks, or deep dents have been detected on the black plastic casings. Corners and joints are intact.
    • Stands: There are no breaks in the monitor stands; they hold the devices stably.
    • Screen Surface: Both monitor panel surfaces show intense wiping marks, undulations, and circular stains. This indicates improper screen cleaning or wear of its coating over time. Scratches cannot be clearly distinguished due to the existing dirt.

    Mechanical Components

    The stand mechanisms that provide height or tilt adjustment for the monitors visually retain their integrity. There are no broken fins in the large ventilation grilles on the rear panel.

    Electronic Components

    The visuals do not show the devices in powered (working) condition. The presence of internal electronic boards can be discerned through the rear ventilation holes, but there is no visual data regarding their condition. The screens are off.

    Accessories

    External power cables or video signal cables (DVI/VGA) are not present in the visuals. Integrated stands are available on the device.

    Battery Status

    The device operates with mains electricity (AC); it is not a battery-powered system.

    Label Information

    The data read from the type label on the back of the device is as follows:

    • (1P) Model No: 5135407
    • (S) Serial No: HXV2000050 (This is the serial number of the single device shown).
    • Revision: 02
    • Item: SMD 21500 G
    • (P) P/N: 6GF6201-4CC13
    • Power Supply: 100 – 240 VAC, 50-60 Hz, 2A
    • Origin: MADE IN GERMANY (Siemens AG)
    • Standards: CE, CSA, VDE, TUV marks are present.

    Screen Analysis

    The screens are in the “off” position. Panel surfaces have a matte (anti-glare) finish. The prominent marks on the screen surface indicate that the panel may require maintenance regarding its cleanliness or the condition of its anti-reflective coating. Dead pixel or color loss analysis could not be performed as the screens were off.

    Size and Compatibility

    Based on the data in the model code (SMD 21500) and physical proportion, the devices are estimated to be 21 inches in size, with an aspect ratio close to square (likely 4:3 or 5:4). They feature standard VESA mounting or an original stand structure for radiology systems.

    Year of Manufacture

    According to the information next to the factory icon on the label, the year of manufacture has been determined as 2007.

    Usage Duration

    No digital or analog operating hour counter was visually detected on the device.

    Documents

    No invoice, warranty certificate, calibration certificate, or user manual is present in the visuals.

    Existing Faults

    No fault that compromises physical integrity (cracked screen, burn marks, broken cable input) was detected during the visual inspection.

    Potential Fault Risk

    The device being manufactured in 2007 (approximately 19-year-old technology) raises the possibility of a weakened backlight system (CCFL fluorescent life). The intense stains on the screen surface suggest that the coating may be damaged; this could affect image quality. A positive detail is the absence of excessive dust around the device’s power input socket (IEC).