Ready For Sale
Secondhand GE 2415364 Shoulder Array MRI Coil
Price: USD$ 5.000,00Approx: 210.000,00 TL
Ready For Sale
Ask a Question
Objective AI Report
Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.
Report date: 14.08.2025
USA Instruments Signa HD 1.5T Phased Array Shoulder Coil Analysis Report
Device Description and Intended Use
The product shown in the images is a coil used in medical imaging systems. According to the label information on the product, this device is identified as a Signa HD 1.5T Phased Array Shoulder Coil. This indicates that the device is used with magnetic resonance (MR) imaging systems, specifically for the detailed imaging of the shoulder region. The 1.5T notation on the label specifies that the device is compatible with MR systems that have a field strength of 1.5 Tesla.
Brand and Model Information
Upon examination of the labels in the images, the brand and model information of the product has been clearly identified. The device is manufactured by USA Instruments, Inc. and distributed by GE Healthcare. The model information is Signa HD 1.5T Phased Array Shoulder Coil.
Quantity Information
The images show 1 unit of the shoulder coil, complete with its cables and connectors.
General Condition and Physical Assessment
Based on visual inspection, the overall condition of the device is assessed as used. Yellowing and discoloration are observed in some areas of the product’s white plastic casing and cables. This indicates that the device is not new and has been used for a certain period.
- Physical Deformation: There are no major cracks, fractures, or dents on the main casing of the device. However, there are superficial scratches and minor stains on its surface due to use. The surface covering the soft pad inside the device shows significant wrinkling and wear from use.
- Mechanical and Electronic Components: The mechanical and external electronic components, such as the device’s screws, connectors, and cable connection points, appear visually intact. No bending or damage has been detected on the connector pins. No breaks or crushing are visible on the cables, although there is yellowing on the cable surfaces.
- Accessories: Apart from the device itself and its integrated cables, no box, user manual, or additional accessories are present in the images.
Technical Label Information
There are multiple labels on the device. The information from two different main labels read from the images is as follows. This suggests that the images may have been taken at different times or focused on different parts.
1. Label Information (S/N: 481)
- Product Name: SIGNA HD 1.5T PHASED ARRAY SHOULDER COIL
- Part Number (P/N): 2415364
- Revision (REV): 1
- Serial Number (S/N): 481
- Field Strength (Field): 1.5T
- Frequency (Frequency): 63.86 Mhz
- Date of Manufacture: 12-2006
2. Label Information (S/N: 1402)
- Product Name: SIGNA HD 1.5T PHASED ARRAY SHOULDER COIL
- Part Number (P/N): 2415364
- Revision (REV): 1
- Serial Number (USA S/N): 1402
- Field Strength (Field): 1.5T
- Frequency (Frequency): 63.86 Mhz
- Date of Manufacture: 02/2009
Additionally, another label visible on the inner part of the device shows the information REV: 2. Certification marks such as CE and US are also present on it.
Potential Risk Assessment
Based on visual evidence, no obvious damage (e.g., broken parts, disconnected cables) indicating an immediate failure has been detected on the device. Considering the age of the device and the signs of use (yellowing, wear on the pad), its condition can be considered normal for a used product. The physical integrity of the connectors and the main body appears to be intact. Therefore, there is no visible significant potential risk of failure.