Ready For Sale
Secondhand Philips Achieva 16 Ch 1.5T MRI Machine
Price: USD$ 110.000,00Approx: 4.620.000,00 TL
Ready For Sale
Ask a Question
Objective AI Report
Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.
Report date: 04.09.2025
Magnetic Resonance (MR) Device Analysis Report
General Assessment and Device Identification
The images show a Magnetic Resonance (MR) device used for medical diagnosis and various accessories belonging to it. The product appears to be a professional medical imaging system. It is understood from the quality of workmanship and design that the device is generally an original manufacturer’s product. Its purpose of use is to assist in the diagnosis of diseases by creating detailed images of the body’s internal organs and tissues. According to visual analysis, the set consists of one MR main unit (gantry), an integrated patient table, and imaging coils.
- Device Type: Magnetic Resonance (MR) Imaging System
- Quantity Information: 1 MR device, 1 integrated patient table, and at least 2 imaging coils.
Physical Condition and Deformation Analysis
The device is clearly used, and its general condition is moderate. The outer casing of the gantry, which is the main unit, is relatively clean and in good condition; no significant cracks, fractures, or large dents have been observed on it. However, the most noticeable wear is concentrated on the patient table.
- Patient Table: There are paint chips, scratches, and wear due to friction on the side edges and corners of the table. This indicates that the device has been actively used.
- Cables and Connectors: A slight yellowing of the color, which has occurred over time, is noticeable on the cables connected to the device. However, no crushing, breakage, or exposed wires have been observed on the cables.
- Surfaces: There is no significant color fading on the device’s general beige surfaces, but it is understood that it may require detailed cleaning.
Mechanical and Electronic Component Examination
Mechanical and electronic components have been examined to the extent permitted by the visuals. In the gantry section of the device, the inside of the tunnel is illuminated, indicating that the system is receiving at least partial power. A control panel is located on the left side of the gantry. The buttons on this panel are physically in place. No obvious malfunction has been visually detected in the patient table’s movement mechanism. The full functional status of the system cannot be definitively determined based solely on visual analysis.
Accessories and Supplementary Parts
The images show some essential accessories required for the device’s operation. Two different imaging coils have been identified. One appears to be designed for head or neck region scans, while the other might be a more general-purpose coil. No expiration date information is visible on the accessories. The coils and their connecting cables have been observed to be physically intact. There are socket inputs on the patient table where the coils can be connected.
Labels and Technical Information
The labels on the device and accessories have been carefully examined, but due to the resolution and viewing angle of the images, no specific technical information such as serial number, REF code, model number, or year of manufacture could be read. Therefore, the identification information and technical details of the device cannot be listed.
Potential Risk Assessment
No broken part or critical damage that would directly impede the device’s operation has been identified in the visual. The main unit of the device appears structurally sound. However, the noticeable cosmetic wear on the patient table and the slight discoloration of the cables indicate a history of long-term and intensive use. While this situation suggests a potential need for future maintenance in the mechanical or electronic components, there is no serious evidence of an immediate malfunction risk in its current state. Considering the device’s overall condition, age, and usage history, potential buyers are advised to conduct a detailed technical inspection.