Ready For Sale
Secondhand Ottobock 6A20=20 Leg Orthosis
Price: USD$ 6.000,00 Approx: 270.000,00 TL
Ready For Sale
Ask a Question
Payment
No additional fees, full assurance. We provide complete financial and operational security in secondhand medical device trading. For this, we offer the "Secure Payment" service. This free service protects the rights of both parties by securing the buyer's money and the seller's product. The Secure Payment system is a standard assurance mechanism offered by Medbidding. For additional information, review the "services" page.
There is no cash on delivery order system on the Medbidding platform. For payments to be made by credit card, the product to be purchased must comply with this payment method. You can contact us to get information about this. We would be happy to assist you.
For payments made outside of Turkiye, you can choose bank transfer, credit card, Western Union or cryptocurrency options. Installment options are not currently available for credit cards other than Turkish banks.
Shipping
Standard Shipping Conditions
In order to ensure secure transactions on Medbidding, the shipping process is managed through four different scenarios depending on the location of the buyer and seller. Free shipping is available for some categories. The terms below apply to all categories unless otherwise stated.
Buyer and Seller in Turkiye
- Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
- Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.
Buyer Outside Turkiye, Seller in Turkiye
- Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
- Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.
Buyer in Turkiye, Seller Outside Turkiye
- Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
- Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.
Buyer and Seller Outside Turkiye
If there is a local operation center in the seller's country:
- Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
- Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.
If there is no operation center in the seller's country:
- Technical Inspection: Inspections are performed by our engineers via remote video call.
- Seller → Buyer: The seller packages the product and sends it directly to the buyer's address. The seller is responsible for this shipping cost.
Objective AI Report
Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.
Report date: 12.01.2026
Ottobock 6A20=20 Mechanism Prosthetic Leg System Analysis Report
Device Identification
The product analyzed in the visuals is a modular prosthetic leg system consisting of a socket, a lock mechanism (shuttle lock), a pylon (tube), and a foot component, used to enable mobilization for amputee individuals. The product is a medical orthopedic aid that includes mechanical connection points and locking systems.
Brand and Model
As a result of a detailed examination of the label located on the product’s connection and lock mechanism, brand and model information has been identified with 100% certainty.
- Brand: Ottobock
- Model/Reference Code: 6A20=20
Note: The 6A20=20 code on the label indicates Ottobock’s lamination anchor and lock system (shuttle lock). The product is considered a complete system built upon this mechanism.
Originality
Upon examination of the font of the “ottobock.” logo on the product, the material quality of the label, technical details of the laser printing (torque values and warning icons), and the product’s workmanship details; it is concluded that the part in question is an original Ottobock production. Furthermore, the “MD” (Medical Device) inscription and CE mark on the label confirm that the product is a medical device compliant with European standards.
Areas of Use
This product is used to help patients who have undergone lower extremity amputation regain their walking functions. The structure of the system in the visual includes a lock mechanism (shuttle lock) that connects the socket (stump receptacle) to other parts of the prosthesis and is used with a pin system. This mechanism ensures the stump securely attaches to the prosthesis for patients using a silicone liner. It is suitable for use in physical therapy and rehabilitation, as well as in orthopedics.
Quantity Information
In the visuals, there is 1 unit of a fully assembled prosthetic leg (socket, mechanism, pylon, and a foot with a shoe). (Note: Although a very small part of a similar socket structure is visible in the background of visual 5, the focal point and the product analyzed is a single unit).
General Condition
The device is a used product. The color of the socket part and slight yellowing on the plastic connection components indicate that the product has been used for a certain period. However, its general condition appears clean, and its structural integrity has been preserved. No missing parts are apparent.
Physical Deformation
No significant rusting or deep scratches have been observed on the product’s metal components. The black anodized metal sections (upper connection part) are in clean condition. However, the following minor signs of use are present:
- Natural color changes (slight yellowing) that can occur over time are present on the white plastic parts under the mechanism (the area where the pin release mechanism is located).
- Surface dullness due to use may be present on the socket (beige-colored hard part), but no cracks or fractures have been detected.
Mechanical Components
The mechanical parts appear sound. The pin release mechanism of the lock system (shuttle lock) is visible with its protruding cord/cable system. No signs of looseness or breakage are visible in the spring systems or screw connection points. The pylon (leg tube) is straight and shows no bending.
Accessories
On the device, there is a black, laceless, leather-like shoe worn to protect the prosthetic foot for daily use. Additionally, the cord/cable assembly used to release the lock system is mounted on the mechanism. External accessories such as a box, user manual, or spare pin are not present in the visuals.
Label Information and Technical Details
The data on the technical label (Visual 6) on the product are as follows:
- Brand: ottobock.
- Reference Code: 6A20=20
- Torque Value (Upper Connection): 20 Nm (Indicates that it should be tightened with 20 Newton-meters of torque).
- Torque Value (Lower Connection): 15 Nm (Indicated near the adjustment screw).
- LOT Number: LOT 0461202422 (Indicates the production batch).
- Carrying Capacity: max. 125kg / 275lbs (User weight limit).
- Certifications: CE Mark, MD (Medical Device) logo.
Size and Compatibility
The label on the product states the maximum user weight as 125 kg (275 lbs). This information indicates that the product is suitable for adult use and resistant to heavy loads. Although body or length measurements cannot be fully determined from the visual, it can be stated that it is of standard adult dimensions.
Existing Defects and Potential Risks
No apparent breakage, detachment, or missing parts (existing defects) that would hinder the device’s operation have been detected in the visuals. As a potential risk, given that the product is used, it should be considered that the internal lock mechanism (springs and gears) may require maintenance over time due to metal fatigue or lack of lubrication. However, from a visual perspective, the product appears to be in good and usable condition.