Sold Out

Whatsapp »
SKU: MBC8COD79DI

Secondhand Respirox SZ-5AW 5L/min Oxygen Concentrator

Price: USD$ 115,00 Approx: 5.060,00 TL

, , , ,

Sold Out

Don't Want To Buy At This Price?

Sorry. This product has been sold. You cannot bid. Please check out other products.

Ask a Question

    Fill in the form below to send us your message. Click the button and wait. We will contact you as soon as possible.


    * We kindly ask you to write your Whatsapp number with the country code so that we can contact you quickly.

    Click once and wait.

    Payment

    No additional fees, full assurance. We provide complete financial and operational security in secondhand medical device trading. For this, we offer the "Secure Payment" service. This free service protects the rights of both parties by securing the buyer's money and the seller's product. The Secure Payment system is a standard assurance mechanism offered by Medbidding. For additional information, review the "services" page.

    There is no cash on delivery order system on the Medbidding platform. For payments to be made by credit card, the product to be purchased must comply with this payment method. You can contact us to get information about this. We would be happy to assist you.

    For payments made outside of Turkiye, you can choose bank transfer, credit card, Western Union or cryptocurrency options. Installment options are not currently available for credit cards other than Turkish banks.

    Shipping

    Standard Shipping Conditions

    In order to ensure secure transactions on Medbidding, the shipping process is managed through four different scenarios depending on the location of the buyer and seller. Free shipping is available for some categories. The terms below apply to all categories unless otherwise stated.

    Buyer and Seller in Turkiye

    • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
    • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

    Buyer Outside of Turkiye, Seller in Turkiye

    • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
    • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

    Buyer in Turkiye, Seller Outside Turkiye

    • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
    • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

    Buyer and Seller Outside Turkiye

    • Technical Inspection: Technical inspections are performed by our business partner in the seller's country (where available) or by our engineers via remote video call.
    • Seller → Buyer: The seller packages the product and sends it to the buyer's address. The seller is responsible for this shipping cost.

    Objective AI Report

    Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.

    Report date: 20.11.2025

    Respirox SZ-5AW Oxygen Concentrator Analysis Report

    Device Identification

    The analyzed visuals belong to a medical respiratory support device. Based on the components on the device’s front panel and the markings on it, this product has been identified as an Oxygen Concentrator that produces oxygen from ambient air and delivers it to the patient. The device features an integrated humidifier reservoir, a flowmeter, and an electronic control panel.

    Brand and Model

    Based on the clear visual data on the front of the device, both on the lower part of the body and on the label, the brand and model of the product are as follows:

    • Brand: Respirox
    • Model: SZ-5AW
    • Device Type: Oxygen Concentrator

    The model name “SZ-5AW” is clearly written in capital letters on the device’s front panel, directly below the logo.

    Originality

    Upon examining the brand logos, model designation, typographic print quality, and information labels on the device’s casing, it is assessed that the product is an original item, manufactured to industrial standards and possessing brand-specific characteristics. The casing joints and panel placement are consistent with original factory production.

    Areas of Use

    This device is designed for patients experiencing respiratory insufficiency or requiring supplementary oxygen support. It operates electrically, drawing ambient air, separating nitrogen, and producing oxygen with over 90% purity. Furthermore, thanks to the “Nebulizing interface” output located on the front panel, the device can also be used for medication vaporization (nebulizer) applications.

    Quantity Information

    The visuals show a total of 1 unit of the main device (Respirox SZ-5AW Oxygen Concentrator). Additionally, various consumables and accessories are visible in the device’s upper storage compartment.

    General Condition and Usage Duration

    The data on the device’s LCD screen provides the clearest information regarding its usage status:

    • Total Usage Hours (Cumulative time): 08947 hrs.
    • Single Run Time: 000 min.

    The cumulative usage period of 8947 hours indicates that the device is a heavily used (second-hand) product. This duration proves that the device has been operated for an extended period during an active patient treatment process. However, visually, the device appears well-maintained and clean.

    Physical Deformations and Cosmetic Condition

    The device’s white plastic casing generally appears clean. On the lower front panel where the “Respirox” logo is located, some hairline surface scratches or minor scuff marks are visible due to light reflection, but no deep cracks, breaks, or severe impact marks have been observed. No significant yellowing of the plastic components has been detected.

    Mechanical and Hardware Components

    The mechanical examination based on the visuals is as follows:

    • Flowmeter: The mechanical flow tube and adjustment knob located on the right side of the device appear intact. The scale ranges from 0-5 L/min.
    • Wheels/Feet: Although the base of the device is not fully visible, its standing position is stable.
    • Humidifier Slot: A humidifier water container is installed in the transparent-covered/recessed area in the middle of the front panel.
    • Lids and Hinges: The lid of the accessory storage compartment on the top of the device is open, and the hinge mechanism appears sound.

    Electronic Components and Screen Analysis

    The device appears to be connected to electricity, and its screen is active:

    • Screen: The blue-backlit LCD screen is operational. There are no missing pixels or readability issues. A green light is illuminated next to the “I/O” indicator on the screen, indicating that the device is receiving power or is turned on.
    • Control Panel: To the right of the screen, there are “+” and “-” adjustment buttons and the main power switch. No excessive wear or fading has been observed on the buttons.
    • Connection Ports: The “Oxygen outlet” (metal output tip) and “Nebulizing interface” (nebulizer output) ports are sound and clean; no signs of oxidation or rust are visible.

    Accessories and Contents

    Aside from the device itself, the following accessories are visible in the storage compartment under the top lid:

    • Oxygen Cannula: 1 unit of a tube-form cannula or extension tube, removed from its transparent pouch.
    • Filter: 1 unit of a black, spongy spare filter (likely an air intake filter) inside a sealed bag.
    • User Manual/Document: A piece of paper or booklet with text is present on the compartment floor (text is not readable).
    • Power Cable: A black electrical cable is visible emerging from the bottom of the device.
    • Humidifier Bottle: Attached to the front body of the device.

    Battery Status

    This type of home-use/stationary oxygen concentrator typically operates solely on mains electricity. The visuals do not indicate an external battery pack or internal battery usage. The device is designed for wired operation.

    Current Faults and Potential Risks

    No error codes or warning symbols (Alarm triangle or Service icon) are active on the device’s screen; the system appears to be in normal operating (standby or running) mode. However, considering the high usage life of 8947 hours, it is technically highly probable that the zeolite tanks (molecular sieves) or the compressor inside the device are due for maintenance. Visually, there is no risk of obvious broken or detached parts requiring immediate intervention.