Ready For Sale
Secondhand Biolight M12 Patient Monitor
Price: USD$ 2.000,00Approx: 84.000,00 TL
Ready For Sale
Ask a Question
Objective AI Report
Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.
Report date: 22.08.2025
AnyView M12 Patient Monitor Analysis Report
Overview and Device Identification
The product shown in the images is a patient bedside monitor used for tracking patients’ vital signs and various accessories belonging to this monitor. The device’s model is clearly stated as AnyView M12 at the top of the screen. It is understood that the product set is generally intended for use in clinical or hospital environments.
Brand and Model Information
During a detailed examination, information belonging to different brands was found on the main device and its accessories. This information is summarized below:
- Main Monitor Brand/Model: The device itself is the AnyView M12 model. Regarding the manufacturer, labels belonging to INOVELL and OPTOMED brands are also present on the monitor. Verification searches conducted online indicate that the AnyView M12 model is a patient monitor manufactured by Biolight company.
- CO₂ Module Brand/Model: The white external carbon dioxide measurement module included in the set bears the BLT brand logo and the inscription “Micro-flow CO₂ Module”.
- Blood Pressure Cuff Brand: The blood pressure measurement cuff bears BTD brand information.
General Status and Condition
The device and its accessories were photographed without any original box or packaging. This indicates that the product is not new. They generally have a clean and well-maintained appearance. The device’s condition can be evaluated as “lightly used” or “in good condition”. No significant physical damage is noticeable on the screen or the device casing.
Physical Deformation Examination
Upon examining the monitor’s casing and screen, no cracks, breaks, or deep scratches were detected. There may be slight traces of use on the surfaces, but these are not prominent. The control buttons and rotary potentiometer on the device’s front panel appear to be in place and undamaged. No crushing, tearing, or significant wear was observed on the outer surfaces of the cables and connectors.
Accessories and Complementary Products
The following accessories were identified with the monitor in the images:
- BTD Blood Pressure Cuff: A complete blood pressure cuff, suitable for adults with dimensions of 25-35 cm, including its hose, is present.
- BLT Micro-flow CO₂ Module: It is an external carbon dioxide measurement unit.
- SpO₂ Finger Sensor: A clip-type finger probe used to measure blood oxygen saturation.
- ECG Cable: A multi-lead ECG cable with the warning “DO NOT THROW AWAY” (Atmayınız).
- Power Cable: A standard power cable to provide electrical connection to the device.
- Data Cable: A blue-colored connection cable, likely used for the CO₂ module.
Label and Code Information
The following information can be read from the labels on the products:
- Information on the ECG Cable:
- Brand: DOBİL
- Part Number (PN): 15-031-00013
- Serial/Lot Number: JSY87-20220600098
- Labels on the Monitor: On the front face of the monitor, there is a label belonging to the INOVELL brand and OPTOMED labels that may belong to a maintenance or calibration company. The OPTOMED label has a marking for the year 2023.
Potential Risk Assessment
Based on visual evidence, no clear situation indicating an immediate risk of malfunction in the device has been identified. Potential sources of failure such as crushed cables, cracked casing, or rusted connectors are not observed. The general physical condition of the device is good. However, since the monitor’s screen is off and not displayed in working condition, no comment can be made regarding the functionality of the electronic components.