Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.
Report date: 23.03.2026
Report code: 1774261466
Mega-Term M-100 Sterilizer Analysis Report
Device Identification and Area of Use
The product shown in the visuals is a desktop sterilizer device. According to the inscriptions on its front panel, it is manufactured for use in the sterilization of cosmetic tools.
Brand and Model Information
The brand of the device has been identified as Mega-Term, and its model as M-100.
Quantity Information
- 1 sterilizer main unit
- 2 perforated metal inner shelves
General Condition and Originality
The device is in used condition. The brand prints on it, the specially designed lid latch, and the CE mark on the front panel indicate that the product is an original production.
Physical and Mechanical Deformation Analysis
No significant scratches, dents, discoloration, or rust have been observed on the device’s white outer metal casing. The gray plastic lid on the upper part is in sound condition. The lid hinges and the metal locking pin on the main body are in place. It is clearly visible that the thick gray rubber gasket, located on the device’s lid and providing insulation, has come out of its groove from the bottom and is hanging loose.
Control Panel and Display Analysis
On the gray and blue control panel sticker located on the front face of the device, there are noticeable bulges and undulations, especially around the buttons and lights. There is no digital display on the panel. The components on the control panel are as follows:
- Upper adjustment knob graduated between 0 and 120 values
- Lower adjustment knob graduated between 50 and 300 values
- Two red indicator lights with THERMOSTAT ON and THERMOSTAT OFF warnings
- Red main power switch with ON and OFF positions, labeled POWER
Existing Fault and Potential Fault Risk
The dislodged insulation gasket inside the lid is the most prominent mechanical issue observed. This situation prevents complete sealing when the device’s lid is closed and creates a potential for heat leakage during operation. The bulges on the front panel sticker are an aesthetic deformation and carry the risk of the sticker tearing or restricting the movement of the adjustment knobs in the future.